ACUTECH AQ4041EZ-M3-12-TRL

AQ4041
Precision Micropower
Shunt Voltage Reference
SOT23, SC70, and TO92 Package
Product Specification
Revision 1.1
General Description
June 14, 2007
Applications
The AQ4041 is a precision voltage
reference offered in very small packages
SOT23 and SC70 for applications where
power and space are critical. Its precision
reference is trimmed during wafer sort to
insure accuracy and tight distributions
centered at 1.225V. The minimum
operating current is less than 40 µA to keep
power consumption at a minimum. The
bandgap reference has curvature correction
and low dynamic impedance to ensure
stable accuracy over a wide range of
operating currents and temperatures
•
•
•
•
Power supplies
Low TC low voltage reference
Portable, Battery-Powered Equipment
Instrumentation
Features
• Offered in small packages: SOT23 and
•
•
•
•
SC70
40uA to 12mA operation
Low TC voltage reference 100ppm/ºC
Stable with no load capacitance
RoHS compliant
Pin Configuration
Pin Descriptions
Pin Name
Function
CATH
+ Input, nominally 1.225V in normal operation.
Anode
- Ground
NC
www.acutechnology.com
This pin must be left floating or connect to Anode
AQ4041
AQ4041
Acutechnology Semiconductor Inc.
Ordering Information
Device
Operating Tj
%Tol
AQ4041
-40C˚ ≤ 85C˚
0.5
AQ4041
-40C˚ ≤ 85C˚
1.0
VOUT
Wrap
Ordering Number
SOT-23-3
1.225V
T&R
AQ4041EZ-M3-12-TRL
SOT-23-3
1.225V
T&R
AQ4041EY-M3-12-TRL
1.225V
1.225V
1.225V
1.225V
T&R
T&R
T&R
T&R
AQ4041EZ-C5-12-TRL
AQ4041EY-C5-12-TRL
AQ4041EZ-N3-12-TRL
AQ4041EY-N3-12-TRL
PKG Type
AQ4041
-40C˚ ≤ 85C˚
0.5
SC70-5
AQ4041
-40C˚ ≤ 85C˚
1.0
SC70-5
AQ4041
-40C˚ ≤ 85C˚
0.5
TO92-3
AQ4041
-40C˚ ≤ 85C˚
1.0
TO92-3
Note: The TRL parts are Lead Free and RoHS compliant.
Absolute Maximum Ratings
Stress greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the
device. These stress ratings only, and functional operation of the device at these or any conditions beyond
those indicated under recommended Operating Conditions is not implied. Exposure to “Absolute Maximum
Rating” for extended periods may affect device reliability. Use of standard ESD handling precautions is
required.
Parameter
Value
Units
ANODE Forward Current
+50
mA
ANODE Reverse Current
-50
mA
Operating Junction Temperature
150
ºC
Lead Temperature (soldering 10 seconds)
260
ºC
-65 to +150
ºC
2
KV
Storage Temperature Range
ESD (Human Body Model)
Electrical Specifications
Electrical characteristics are guaranteed at 25ºC unless otherwise stated. Ambient temperature must be de-rated
based upon power dissipation and package thermal characteristics.
Symbol
Parameter
Conditions
VR
Reverse Breakdown Voltage
IR =100µA
VR
Reverse Breakdown Voltage
∆VR
IR(min)
∆VR/ ∆IR
VR Temperature deviation
Minimum Operating Current
VR deviation with IR
ZR
θN
∆VR
Dynamic Output Impedance
Wideband Noise
Long term stability
www.acutechnology.com
0.5% option
–40ºC <Tj<85ºC
1.0% option
IR =100µA
–40ºC <Tj<85ºC
–40ºC <Tj<85ºC.
IR(min) ≤ IR ≤ 12 mA
–40ºC <Tj<85ºC
IR=1mA, IAC = 0.1 IR, f = 120Hz
IR=1mA, 10Hz ≤ f ≤ 10 kHz
T =1000 hrs, T =25ºC, IR =100µA
2
Min
Typ
Max
Units
1.219
1.211
1.213
1.201
1.225
1.231
1.239
1.237
1.249
100
40
6
8
1.5
V
V
V
V
ppm/ºC
µA
mV
mV
Ω
µV rms
ppm
1.225
50
18
2
2
0.1
20
120
Rev. 1.1
June 14, 2007
AQ4041
Acutechnology Semiconductor Inc.
Typical performance curves
Cathode current vs Cathode voltage
Reference voltage
vs
Junction temperature
15
1.240
Cathode current (mA)
10
Reference voltage (V)
1.235
1.230
1.225
1.220
5
0
-5
1.215
1.210
-10
-40 -20
0
20 40 60 80 100 120
-1
-0.5
Junction temperature (degrees C)
Cathode current vs Cathode voltage
0.5
1
1.5
Dynamic impedance vs frequency
50
100
Dynamic impedance (0hms)
40
Cathode current (uA)
0
Cathode voltage (V)
30
20
10
0
-10
10
1
0.1
0
0.5
1
1.5
0.1
Cathode voltage (V)
www.acutechnology.com
1
10
100
1000
10000
Frequency (KHz)
3
Rev. 1.1
June 14, 2007
AQ4041
Acutechnology Semiconductor Inc.
Package Dimensions
SOT23-3, SOT23-4, SOT23-5, SOT23-6
www.acutechnology.com
4
Rev. 1.1
June 14, 2007
AQ4041
Acutechnology Semiconductor Inc.
Package Dimensions
TO92-2, TO92-3
www.acutechnology.com
5
Rev. 1.1
June 14, 2007
AQ4041
Acutechnology Semiconductor Inc.
Package Dimensions
SC70-3, SC70-4, SC70-5, SC70-6
Contact Information
Acutechnology Semiconductor Inc.
3487 McKee Rd. Suite 52
San Jose CA , USA 95127
TEL: (408) 259-2300
FAX: (408) 259-9160
website: www.acutechnology.com
Disclaimer
The information furnished by Acutechnology in this data sheet is believed to be accurate and reliable. However,
Acutechnology assumes no responsibility for its use. Acutechnology reserves the right to change circuitry and specifications
at any time without notification to the customer.
Life Support Policy
Acutechnology Products are not designed or authorized for use as components in life support devices or systems where
malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are
devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to
perform can be reasonably expected to result in a significant injury to the user.
www.acutechnology.com
6
Rev. 1.1
June 14, 2007