AEROFLEX IFR6015

Avionics
IFR 6015 Ramp Test Set
The IFR 6015 is a compact, lightweight and weatherproof unit designed for testing transponder
modes A/C/S, TCAS I, II and Military E-TCAS as well as DME.
•
One main user screen for each test mode
•
Detachable antenna
•
Large display
•
Simple user interface
•
Lightweight and compact <8 lbs. (3.6 kg)
•
Battery 6 hours plus duration
•
Fully FAR part 43 appendix F compliant
•
European Elementary and Enhanced
Surveillance
The IFR 6015 features an extremely easy to use
interface where every parameter the user commonly needs to view is displayed on screen.
Controls
Dedicated Mode keys for XPDR, DME and TCAS
allow quick selection of the operational mode.
The application dependant softkeys and data
select/slew keys provide an intuitive man machine
interface.
DME mode is provided with dedicated keys for
frequency/channel selection and RF level control.
For frequently varied parameters in DME and
TCAS modes, such as Range and Rate, dedicated
keys are provided.
Operational Modes
Each operational mode has one main user screen. The operational
modes are:
XPDR (Sub-Modes: ADS-B MON, ADS-B GEN & GICB)
DME
TCAS 1, 2 (Sub-Modes: TIS & TIS-B)
E-TCAS
Most tests can be completed without leaving the main user screens.
This simplifies the line technician's testing task.
For the very latest specifications visit
www.aeroflex.com
Mode S and ATCRBS Transponder
User selects config required for test.
Xpdr Auto-Test:
If the class of the transponder is unknown, the generic config may be
selected which applies to the widest limits.
Every parameter the user commonly needs to view is displayed on one
screen.
The auto-test performs all tests defined by FAR Part 43 Appendix F,
including the proposed Eurocontrol additional tests.
The tests are tailored automatically according to reported transponder level to avoid erroneous failures.
The test set will automatically determine the Mode S transponder
level.
The selected config parameters may be displayed by pressing the
INFO softkey.
Eight predetermined configs are provided to meet the currently fielded transponder test needs.
The test list is selected from the auto-test screen. This provides an
easy means of selecting any of the individual tests that comprise the
auto-test.
Tests on the 2nd screen (not shown) include:
13 UF21
14 UF24
15 ELEMENTARY SURVEILLANCE 1
16 ELEMENTARY SURVEILLANCE 2
15 ENHANCED SURVEILLANCE
The Eurocontrol Elementary Surveillance DAP's (Downlink Aircraft
Parameters) are displayed on two screens
Individual tests may be reviewed for failures which are identified by
an arrow symbol.
Eurocontrol Enhanced Surveillance DAP's are displayed on one screen.
TCAS
No more HEX data field interpretation!
All Mode S Format tests display parameter in engineering units.
TCAS types…
TCAS 1 MODE C
TCAS 2 ATCRBS
TCAS 2 MODE S
E-TCAS
The Auto-Altitude feature interrogates Mode S XPDR of A/C under
test to obtain current altitude.
Select pre-stored named scenarios directly from the auto-test screen.
Comprehensive II / SI code and lockout timer test
ADS-B and GICB
ADS-B MON: Used to monitor DF17 extended squitter from
transponders and DF18 extended squitter from 1090 MHz ADS-B
emitters.
DME
ADS-B GEN: Used to generate DF17/DF18 extended squitter, simulating transponders and 1090 MHz ADS-B emitters.
All the user needs are on one screen.
GICB: Used to monitor DAP's (all fields).
•
RF level control for track sensitivity tests
•
Supports all DME/TACAN channels selectable in VOR paired
channels
•
Full UUT measured parameters are displayed.
For the very latest specifications visit
www.aeroflex.com
ADS-B MON:
The ADS-B MON LIST shows BDS formats supported.
The BDS status is annunciated to indicate if the squitter has been
captured, not available or not seen.
The BDS DATA key displays the BDS DATA screen for the selected
BDS number.
ADS-B GEN:
BDS DATA screens display full content of the selected BDS format in
RTCA/ICAO engineering units.
The NEXT & PREV PARAM keys select data fields for editing via the
data slew keys.
GICB:
ADS-B MON:
The BDS LIST shows BDS formats supported.
The BDS DATA screen displays full content of selected BDS format
being received via DF17, DF18 or DF19 extended squitters.
The BDS DATA key displays the BDS DATA screen for the selected
BDS number.
ADS-B GEN:
GICB:
The BDS LIST shows BDS formats supported. The BDS SELECT
key selects individual BDS numbers. The BDS ENABLE/DISABLE
key enables or disables the selected BDS number for squittering via
DF17 or DF18 extended squitter. The BDS DATA key displays the
BDS DATA screen for the selected BDS number.
BDS DATA screens display full content of the selected BDS format
being received via GICB DF20 or DF21 in RTCA/ICAO engineering
units.
TIS
Up to 5 static intruders may be simulated relative to the A/C (UUT).
TIS-B:
The user enters the A/C (UUT) LAT/LONG and heading.
Up to 5 static intruders may be simulated relative to the A/C (UUT).
SPECIFICATION
DME MODE SPECIFICATIONS
General
SIGNAL GENERATOR
Radiated Testing:
The IFR 6015 is supplied with a lightweight fully sealed directional
antenna that may be test set mounted, hand held or tripod mounted.
A 5-minute warm-up period is required for all specifications.
OUTPUT FREQUENCY
Direct Connect Testing:
REPLY FREQUENCY
The IFR 6015 may be directly connected to the UUT via a supplied
RF coax cable via the RF I/O port.
Range
962 to 1213 MHz
Accuracy
± 10 kHz
OUTPUT LEVEL
ANTENNA PORT
Range
-67 to -2 dBm at Antenna port
Resolution
1 dB
Accuracy
± 2 dB
Distance to UUT antenna
6 to 300 ft with supplied antenna
Transit Case:
The IFR 6015 is supplied in a rugged plastic transit case which provides stowage for the test set, directional antenna, RF coax cable,
antenna shield, breakout box, and power supply/charger.
RF I/O PORT
Range
-115 to -47 dBm
Resolution
1 dB
Accuracy
-95 dBm to –47 dBm
± 1 dB
Accuracy
-115 dBm to <-95 dBm
± 2 dB
REPLY PULSE SPACING
P1 to P2
12 µs ± 100 ns (X Channel) @ 50% peak
P1 to P2
30 µs ± 100 ns (Y Channel) @ 50% peak
For the very latest specifications visit
www.aeroflex.com
REPLY PULSE WIDTH
IDENT TONE
P1/P2
Selection
3.5 µs ± 0.5 µs
ECHO REPLY
Control
On/Off
Position
30 nmi ± 1 nmi
Amplitude
-11 dB ± 1 dB relative to reply level
REPLY PULSE RISE AND FALL TIMES
ALL PULSES
Rise Time
2.5 µs ± 0.25 µs (10% to 90%)
Fall Time
2.5 µs ± 0.25 µs (90% to 10%)
REPLY DELAY
X CHANNEL
Fixed Reply Delay
50 µs ± 100 ns
Y CHANNEL
Fixed Reply Delay
56 µs ± 100 ns
RANGE DELAY
X AND Y CHANNEL
Range
0 to 450.00 nmi
Resolution
0.01 nmi
Accuracy
± 0.01 nmi
RANGE RATE
X AND Y CHANNEL
Range
10 to 6500 kts
Resolution
1 kts
Accuracy
± 0.01% typical, tested to ± 0.5%
SQUITTER
PRF
2700 Hz
Accuracy
± 2%
Distribution
Per ARINC 568
Selectable three letter code
Frequency
1350 Hz
Accuracy
± 2 Hz
UUT MEASUREMENTS
ERP
Range
+47 to +64 dBm
Resolution
0.1 dB
Accuracy
± 2 dB
DIRECT CONNECTION PEAK PULSE POWER
Range
+47 to +64 dBm
Resolution
0.1 dB
Accuracy
± 1 dB
FREQUENCY
Range
1025.00 to 1150.00 MHz
Resolution
10 kHz
Accuracy
± 20 kHz
INTERROGATION PULSE WIDTH
P1 AND P2 PULSE WIDTHS
Range
2.00 to 5.00 µs
Resolution
1 ns
Accuracy
± 50 ns
INTERROGATION PULSE SPACING
P1 to P2 Spacing
10 to 14 µs (X Channel)
P1 to P2 Spacing
34 to 38 µs (Y Channel)
Resolution
10 ns
Accuracy
± 20 ns
REPLY EFFICIENCY
INTERROGATION PRF
Range
Range
0 to 100%
Resolution
1% increments
1 to 300 Hz
Resolution
1 Hz
Accuracy
Accuracy
± 0.5%
± 2 Hz
TRANSPONDER MODE SPECIFICATIONS
P1 to P4
SIGNAL GENERATOR
MODE C
RF OUTPUT FREQUENCY
P1 to P3
10.00 µs ± 25 ns
21.00 µs ± 25 ns
Interrogation Frequency
P1 to P4
1030 MHz
23.00 µs ± 25 ns
Accuracy
INTERROGATION PULSE WIDTHS
± 10 kHz
RF OUTPUT LEVEL
MODE A,C,S,INTERMODE
ANTENNA PORT
P1,P2,P3
MTL + 6 dB typical, automatically controlled for a MTL range of -83 to
-68 dBm
Range
0.80 µs ± 50 ns
MODE S
P6 (Short DPSK Block)
-67 to -2 dBm at antenna port
Resolution
16.25 µs ± 50 ns
P6 (Long DPSK Block)
0.5 dB
30.25 µs ± 50 ns
Accuracy
P5
± 2 dB
0.80 µs ± 50 ns
Distance to UUT antenna
6 to 200 ft with supplied antenna
RF I/O PORT
MTL + 6 dB typical, automatically controlled
Range
INTERMODE
P4 (Short)
0.80 µs ± 50 ns
P4 (Long)
1.60 µs ± 50 ns
-115 to -47 dBm
Resolution
INTERROGATION PULSE RISE AND FALL TIMES
ALL MODES
0.5 dB
Rise Time
Accuracy
-95 to –47 dBm, ± 1 dB
Accuracy
-115 to <-95 dBm, ± 2 dB
ATCRBS/MODE S INTERROGATION PULSE SPACING
50 to 100 ns
Fall Time
50 to 200 ns
PHASE MODULATION
ALL MODES
MODE A
Transition Time
P1 to P2
2.00 µs ± 25 ns
P1 to P3
8.00 µs ± 25 ns
≤ 80 ns
Phase Shift
180° ± 10°
MODE C
SLS LEVELS
P1 to P2
ATCRBS
2.00 µs ± 25 ns
P1 to P3
SLS Level (P2)
-9 dB, -1 to +0 dB relative to P1 level
21.00 µs ± 25 ns
MODE S
0 dB, -0 to +1 dB relative to P1 level
Off
P1 to P2
MODE S
2.00 µs ± 25 ns
P1 to P6
SLS Level (P5)
-12 dB, -1 to +0 dB relative to P6 level
3.50 µs ± 25 ns
P1 to SPR
+3 dB, -0 to +1 dB relative to P6 level
Off
4.75 µs ± 25 ns
P5 to SPR
0.40 µs ± 50 ns
INTERMODE INTERROGATION PULSE SPACING
MODE A
Note: SLS level is automatically controlled in the SLS LEVEL test.
INTERROGATION TEST SIGNALS
MODE S
PRF
50 Hz ± 5 Hz
P1 to P3
8.00 µs ± 25 ns
For the very latest specifications visit
www.aeroflex.com
ATCRBS
REPLY DELAY JITTER
PRF
ATCRBS
235 Hz ± 5 Hz
UUT MEASUREMENTS
ERP (@ 1090 MHZ)
Range
+ 45.5 to + 59 dBm (35.5 to 800 watts)
Resolution
0.1 dB
Accuracy
± 2 dB
Direct Connection Peak Pulse Power (@1090 MHz)
Range
+ 46.5 to + 59 dBm (45 to 800 watts)
Resolution
0.1 dB
Accuracy
± 1 dB
TRANSMITTER FREQUENCY
Range
1087.000 to 1093.000 MHz
Resolution
10 kHz
Accuracy
± 50 kHz
RECEIVER SENSITIVITY, RADIATED MTL
Range
-67 to -79 dBm into 0 dBi antenna
Resolution
0.1 dB
Accuracy
± 2 dB, typical
RECEIVER SENSITIVITY, DIRECT CONNECTION MTL
Range
-67 to -79 dBm
Resolution
0.1 dB
Accuracy
± 2 dB
REPLY DELAY
Range
0.00 to 2.30 µs
Resolution
1 ns
Accuracy
± 20 ns
MODE S AND ATCRBS MODE S ALL-CALL
Range
0.00 to 6.00 µs
Resolution
1 ns
Accuracy
± 20 ns
PULSE SPACING
F1 TO F2
Range
19.70 to 21.60 µs
Resolution
1 ns
Accuracy
± 20 ns
MODE S PREAMBLE
Range, P1 to P2
0.8 to 1.2 µs
Range, P1 to P3
3.3 to 3.7 µs
Range, P1 to P4
4.3 to 4.7 µs
Resolution
1 ns
Accuracy
± 20 ns
PULSE WIDTHS
F1 AND F2
Range
0.25 to 0.75 µs
Resolution
1 ns
Accuracy
± 20 ns
ATCRBS
MODE S PREAMBLE
Range
Range
1.80 to 7.00 µs
Resolution
10 ns
Accuracy
± 50 ns
REPLY DELAY, MODE S AND ATCRBS MODE S ALL-CALL
Range
125.00 to 131.00 µs
Resolution
10 ns
Accuracy
± 50 ns
0.25 to 0.75 µs
Resolution
1 ns
Accuracy
± 20 ns
PULSE AMPLITUDE VARIATION
Range, Mode S (Relative to P1)
+3 to -3 dB
Range, ATCRBS (Relative to F1)
+3 to -3 dB
Resolution
0.1 dB (0.01 dB via RCI)
F1 to C1
Accuracy
1.45 µs ± 25 ns
± 0.5 dB
DF 11 SQUITTER PERIOD
F1 to A1
2.90 µs ± 25 ns
Range
0.10 to 4.88 sec
Resolution
F1 to C2
4.35 µs ± 25 ns
F1 to A2
10 ms
5.80 µs ± 25 ns
Accuracy
F1 to C4
± 10 ms
7.25 µs ± 25 ns
DIVERSITY ISOLATION
F1 to A4
8.70 µs ± 25 ns
Range
0 to >20 dB (Depending on Test Distance)
F1 to B1
11.60 µs ± 25 ns
Test Distance
1.83m (6ft) to 28.96m (95ft)
F1 to D1
13.05 µs ± 25 ns
Resolution
F1 to B2
0.1 dB
14.50 µs ± 25 ns
Accuracy
F1 to D2
± 3 dB
TCAS MODE SPECIFICATIONS
SIGNAL GENERATOR
OUTPUT FREQUENCY
REPLY FREQUENCY
1090 MHz
15.95 µs ± 25 ns
F1 to B4
17.40 µs ± 25 ns
F1 to D4
18.85 µs ± 25 ns
MODE S
P1 to P2
Accuracy
1.00 µs ± 25 ns
± 10 kHz
P1 to P3
OUTPUT LEVEL (SIMULATED ERP)
ANTENNA PORT
Note 1
Radiated power at 0dBi UUT antenna
-68 dBm typical @ 10 Nmi Range, automatically controlled
Range
-67 to -2 dBm at Antenna port
Resolution
3.50 µs ± 25 ns
P1 to P4
4.50 µs ± 25 ns
P1 to D1
8.00 µs ± 25 ns
D1 to Dn (n=2 to 112)
1.00 µs times (n-1) ± 25 ns
REPLY PULSE WIDTHS
0.5 dB
Accuracy
MODE C
± 2 dB
All Pulses
Distance to UUT antenna
6 to 300 ft with supplied antenna
RF I/O PORT
Automatic mode
-68 dBm @ 10 Nmi Range, automatically controlled
Manual mode Range
-115 to -47 dBm
Resolution
0.45 µs ± 50 ns
MODE S
P1 through P4
0.50 µs ± 50 ns
D1 through D112
0.50 µs ± 50 ns, 1 µs chip width
Reply Modes
TCAS I / II Mode C (with altitude reporting)
0.5 dB
TCAS II Mode S formats 0, 11, 16
Accuracy
E-TCAS Modes formats 0, 4, 5, 11, 16, 20, 21
-95 to –47 dBm, ± 1 dB
Accuracy
-115 to <-95 dBm, ± 2 dB
REPLY PULSE SPACING
MODE C
REPLY PULSE AMPLITUDES
ATCRBS
± 1 dB relative to F1
Mode S
± 1 dB relative to P1
F1 to F2
20.30 µs ± 25 ns
For the very latest specifications visit
www.aeroflex.com
REPLY PULSE RISE AND FALL TIMES
RECEIVER
ALL MODES
PULSE SPACING
Rise Time
ATCRBS (Mode C All Call)
50 to 100 ns
Fall Time
50 to 200 ns
PERCENT REPLY
Range
0 to 100%
Resolution
10%
Accuracy
± 1%
REPLY DELAY
ATCRBS
3.0 µs ± 50 ns
Mode S
128 µs ± 50 ns
S1 to P1
≤ ±200 ns
Rejects
≥ ±1.0 us
P1 to P3
Accepts
Accepts
≥ ±1.0 us
23.0 us
≤ ±200 ns
Rejects (<10% Replies)
≥ ±1.0 us
Mode S
P1 to P2
Accepts
2.0 us
≤ ±200 ns
Rejects (<10% Replies)
P1 to SPR
Accepts
Range
ATCRBS (P2 or S1)
≥ ±1.0 us
4.75 us
≤ ±200 ns
Rejects (<10% Replies)
SUPPRESION
Resolution
21.0 us
≤ ±200 ns
Rejects (<10% Replies)
P1 to P4
RANGE DELAY
0 to 260 nmi
2.0 us
Accepts
>0.5dB above level of P1
≥ ±1.5 us
<10% Replies
UUT MEASUREMENTS
0.1 nmi
Accuracy
± 0.02 nmi
RANGE RATE
Range
-1200 to +1200 kts
Resolution
10 kts
Accuracy
10%
ALTITUDE RANGE
Range
-1000 to 126,000 ft
Resolution, Mode C
100 ft
Resolution, Mode S
25 ft
ALTITUDE RATE
Range
-10,000 to +10,000 fpm
ERP (@1030MHZ)
ATCRBS
Range
+43 to +58 dBm (20 to 631 watts)
Resolution
0.1 dB
Accuracy
± 2 dB
MODE S
Range
+43 to +58 dBm (20 to 631 watts)
Resolution
0.1 dB
Accuracy
± 2 dB
DIRECT CONNECTION PEAK PULSE POWER (@1030MHZ)
ATCRBS
Range
+43 to +58 dBm (20 to 631 watts)
Resolution
Resolution
0.1 dB
100 fpm
Accuracy
Accuracy
10%
SQUITTER
Control
On/Off
Rate
0.8 to 1.2 seconds, randomly distributed
± 1 dB
MODE S
Range
+43 to +58 dBm (20 to 631 watts)
Resolution
0.1 dB
Accuracy
± 1 dB
FREQUENCY
Aging
± 1 ppm per year
Range
1029.900 to 1030.100 MHz
Resolution
Accuracy
± 1 ppm
Test Limit
1 kHz
± 0.3 ppm
Accuracy
± 10 kHz
BATTERY
TCAS BROADCAST INTERVAL
Type
Li Ion
Range
1.0 to 12.0 sec
Resolution
Duration
> 4 hrs continuous operation
> 6 hrs, Typical
0.1 sec
Accuracy
INPUT POWER (TEST SET)
± 0.2 sec
Input Range
MISCELLANEOUS INPUT/OUTPUTS
11 VDC to 32 VDC
Power Consumption
RF I/O
55 W Maximum
Type
Input/Output
Impedance
50 Ω typical
Maximum Input Level
16 W Nominal at 18 VDC with charged battery
Fuse Requirements
5 A, 32 VDC, Type F
4 kW peak
INPUT POWER (SUPPLIED EXTERNAL AC TO DC
CONVERTER)
10 W average
Input Range
VSWR
100 to 250 VAC, 1.5 A Max, 47-63 Hz
< 1.3:1
Mains Supply Voltage Fluctuations
ANTENNA
≤ 10% of the nominal voltage
Type
Transient Overvoltages
Input/Output
Impedance
50 Ω typical
Maximum Input Level
10 W peak
1/2 W average
VIDEO
According to Installation Category II
ENVIRONMENTAL (TEST SET)
Use
Pollution Degree 2
Altitude
≤ 4800 meters
Operating Temperature
Type
NOTE 3
Output
-20°C to 55°C
Storage Temperature
Impedance
50 Ω typical
Generate Video Level
1.1 ± 0.4V peak to peak into 50 Ω
Receive Video Level
Proportional to IF level
Baseline
± 0.5V referenced to ground
TEST ANTENNA
NOTE 4
-30°C to 71°C
Relative Humidity
95% ±5% from 5° to 30°C
75% ±5% from 30° to 40°C
45% ±5% from 40° to 55°C
ENVIRONMENTAL (SUPPLIED EXTERNAL AC TO DC
CONVERTER)
Use
Indoors
VSWR
Altitude
< 1.5:1
≤ 10,000 meters
Gain
6 dB, Typical
TIME BASE (TCXO)
Temperature Stability
Operating Temperature
0° to 40°C
Storage Temperature
-20°C to 71°C
± 1 ppm
For the very latest specifications visit
www.aeroflex.com
PHYSICAL CHARACTERISTICS
Notes
DIMENSIONS
Height
11.2 inches (28.5 cm)
Width
9.1 inches (23.1 cm)
Depth
2.7 inches (6.9 cm)
Weight (Test set only)
< 8 lbs. (3.6 kg)
NOTE 1
Simulates a 50.5 dBm XPDR ERP at 10 nMi range.
NOTE 2
Level automatically controlled based on actual distance to UUT antenna.
NOTE 3
Battery charging temperature range: 5°C to 40°C (controlled by internal
charger).
NOTE 4
Li Ion Battery must be removed below -20°C and above 60°C.
NOTE 5
Temperature range extended to -20°C to 55°C.
NOTE 6
Temperature range reduced to -30°C to 71°C.
VERSIONS AND ACCESSORIES
SUPPLEMENTAL INFORMATION
When ordering please quote the full ordering number information.
Test Set Certifications
Altitude, operating
Altitude, not operating
Bench Handling
Blowing Dust
MIL-PRF-28800F
MIL-PRF-28800F
MIL-PRF-28800F
MIL-STD-810F
Drip-proof
Explosive Atmosphere
MIL-PRF-28800F
MIL-STD-810F
Relative Humidity
Shock, Functional
Vibration Limits
Temp, operating NOTE 5
Temp, not operating NOTE 6
Transit Drop
Safety Compliance
MIL-PRF-28800F
MIL-PRF-28800F
MIL-PRF-28800F
MIL-PRF-28800F
MIL-PRF-28800F
MIL-PRF-28800F
UL-61010B-1
EN 61010-1
CSA 22.2 No 61010-1
EN 61326
EMC
Class 2
Class 2
Class 2
Method 510.4,
Procedure I
Class 2
Method 511.4,
Procedure 1
Class 2
Class 2
Class 2
Class 2
Class 2
Class 2
EXTERNAL AC-DC CONVERTER CERTIFICATIONS
Safety Compliance
EMI/RFI Compliance
EMC
UL 1950 DS
CSA 22.2 No. 234
VDE EN 60 950
FCC Docket 20780 Curve “B”
EN 61326
TRANSIT CASE CERTIFICATIONS
Drop Test
Falling Dart Impact
Vibration, Loose Cargo
Vibration, Sweep
Simulated Rainfall
FED-STD-101C
ATA 300
FED-STD-101C
ATA 300
MIL-STD-810F
FED-STD-101C
Immersion
MIL-STD-810F
Method 5007.1
Paragraph 6.3,
Procedure A,
Level A
Category I
Method 5019
Category I
Method 506.4
Procedure II of 4.1.2
Method 5009.1
Sec 6.7.1
Method 512.4
Ordering
Numbers
6015-110
6015-220
IFR 6015 Mode A/C/S Transponder, DME,
TCAS/E-TCAS, TIS and TIS-B Ramp Test Set,
with European Mains Leads
6015OPT3
ADS-B
Extended Standard Warranties with Calibration for 6015
W6015/203C
Extended standard warranty 36 months with
scheduled calibration
W6015/205C
Extended standard warranty 60 months with
scheduled calibration
Accessories for 6015
AC0820
Desk Top Stand
AC0826
Tripod
AC0825CD
IFR 6015 Operation Manual - CD
AC24006
Tripod, Dolly, Stand
EXPORT CONTROL:
This product is controlled for export under the International Traffic
in Arms Regulations (ITAR). A license from the U.S. Department of
State is required prior to the export of this product from the United
States.
EXPORT WARNING:
Aeroflex's military products are controlled for export under the
International Traffic in Arms Regulations (ITAR) and may not be
sold or proposed or offered for sale to certain countries including:
Belarus, Burma, China, Cuba, Haiti, Iran, Liberia, Libya, North
Korea, Somalia, Syria, Sudan, and Vietnam. See ITAR 126.1 for complete information.
FINLAND
Tel: [+358] (9) 2709 5541
Fax: [+358] (9) 804 2441
INDIA
Tel: [+91] 80 5115 4501
Fax: [+91] 80 5115 4502
SPAIN
Tel: [+34] (91) 640 11 34
Fax: [+34] (91) 640 06 40
FRANCE
Tel: [+33] 1 60 79 96 00
Fax: [+33] 1 60 77 69 22
KOREA
Tel: [+82] (2) 3424 2719
Fax: [+82] (2) 3424 8620
UK Burnham
Tel: [+44] (0) 1628 604455
Fax: [+44] (0) 1628 662017
GERMANY
Tel: [+49] 8131 2926-0
Fax: [+49] 8131 2926-130
SCANDINAVIA
Tel: [+45] 9614 0045
Fax: [+45] 9614 0047
UK Cambridge
Tel: [+44] (0) 1763 262277
Fax: [+44] (0) 1763 285353
As we are always seeking to improve our products,
the information in this document gives only a general
indication of the product capacity, performance and
suitability, none of which shall form part of any contract. We reserve the right to make design changes
without notice. All trademarks are acknowledged.
Parent company Aeroflex, Inc. ©Aeroflex 2006.
Versions
IFR 6015 Mode A/C/S Transponder, DME,
TCAS/E-TCAS, TIS and TIS-B Ramp Test Set,
with US Mains Leads
UK Stevenage
Tel: [+44] (0) 1438 742200
Fax: [+44] (0) 1438 727601
Freephone: 0800 282388
USA
Tel: [+1] (316) 522 4981
Fax: [+1] (316) 522 1360
Toll Free: 800 835 2352
w w w.aeroflex.com
[email protected]
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused.
Part No. 46891/263, Issue 1, 01/06