Avionics IFR 6015 Ramp Test Set The IFR 6015 is a compact, lightweight and weatherproof unit designed for testing transponder modes A/C/S, TCAS I, II and Military E-TCAS as well as DME. • One main user screen for each test mode • Detachable antenna • Large display • Simple user interface • Lightweight and compact <8 lbs. (3.6 kg) • Battery 6 hours plus duration • Fully FAR part 43 appendix F compliant • European Elementary and Enhanced Surveillance The IFR 6015 features an extremely easy to use interface where every parameter the user commonly needs to view is displayed on screen. Controls Dedicated Mode keys for XPDR, DME and TCAS allow quick selection of the operational mode. The application dependant softkeys and data select/slew keys provide an intuitive man machine interface. DME mode is provided with dedicated keys for frequency/channel selection and RF level control. For frequently varied parameters in DME and TCAS modes, such as Range and Rate, dedicated keys are provided. Operational Modes Each operational mode has one main user screen. The operational modes are: XPDR (Sub-Modes: ADS-B MON, ADS-B GEN & GICB) DME TCAS 1, 2 (Sub-Modes: TIS & TIS-B) E-TCAS Most tests can be completed without leaving the main user screens. This simplifies the line technician's testing task. For the very latest specifications visit www.aeroflex.com Mode S and ATCRBS Transponder User selects config required for test. Xpdr Auto-Test: If the class of the transponder is unknown, the generic config may be selected which applies to the widest limits. Every parameter the user commonly needs to view is displayed on one screen. The auto-test performs all tests defined by FAR Part 43 Appendix F, including the proposed Eurocontrol additional tests. The tests are tailored automatically according to reported transponder level to avoid erroneous failures. The test set will automatically determine the Mode S transponder level. The selected config parameters may be displayed by pressing the INFO softkey. Eight predetermined configs are provided to meet the currently fielded transponder test needs. The test list is selected from the auto-test screen. This provides an easy means of selecting any of the individual tests that comprise the auto-test. Tests on the 2nd screen (not shown) include: 13 UF21 14 UF24 15 ELEMENTARY SURVEILLANCE 1 16 ELEMENTARY SURVEILLANCE 2 15 ENHANCED SURVEILLANCE The Eurocontrol Elementary Surveillance DAP's (Downlink Aircraft Parameters) are displayed on two screens Individual tests may be reviewed for failures which are identified by an arrow symbol. Eurocontrol Enhanced Surveillance DAP's are displayed on one screen. TCAS No more HEX data field interpretation! All Mode S Format tests display parameter in engineering units. TCAS types… TCAS 1 MODE C TCAS 2 ATCRBS TCAS 2 MODE S E-TCAS The Auto-Altitude feature interrogates Mode S XPDR of A/C under test to obtain current altitude. Select pre-stored named scenarios directly from the auto-test screen. Comprehensive II / SI code and lockout timer test ADS-B and GICB ADS-B MON: Used to monitor DF17 extended squitter from transponders and DF18 extended squitter from 1090 MHz ADS-B emitters. DME ADS-B GEN: Used to generate DF17/DF18 extended squitter, simulating transponders and 1090 MHz ADS-B emitters. All the user needs are on one screen. GICB: Used to monitor DAP's (all fields). • RF level control for track sensitivity tests • Supports all DME/TACAN channels selectable in VOR paired channels • Full UUT measured parameters are displayed. For the very latest specifications visit www.aeroflex.com ADS-B MON: The ADS-B MON LIST shows BDS formats supported. The BDS status is annunciated to indicate if the squitter has been captured, not available or not seen. The BDS DATA key displays the BDS DATA screen for the selected BDS number. ADS-B GEN: BDS DATA screens display full content of the selected BDS format in RTCA/ICAO engineering units. The NEXT & PREV PARAM keys select data fields for editing via the data slew keys. GICB: ADS-B MON: The BDS LIST shows BDS formats supported. The BDS DATA screen displays full content of selected BDS format being received via DF17, DF18 or DF19 extended squitters. The BDS DATA key displays the BDS DATA screen for the selected BDS number. ADS-B GEN: GICB: The BDS LIST shows BDS formats supported. The BDS SELECT key selects individual BDS numbers. The BDS ENABLE/DISABLE key enables or disables the selected BDS number for squittering via DF17 or DF18 extended squitter. The BDS DATA key displays the BDS DATA screen for the selected BDS number. BDS DATA screens display full content of the selected BDS format being received via GICB DF20 or DF21 in RTCA/ICAO engineering units. TIS Up to 5 static intruders may be simulated relative to the A/C (UUT). TIS-B: The user enters the A/C (UUT) LAT/LONG and heading. Up to 5 static intruders may be simulated relative to the A/C (UUT). SPECIFICATION DME MODE SPECIFICATIONS General SIGNAL GENERATOR Radiated Testing: The IFR 6015 is supplied with a lightweight fully sealed directional antenna that may be test set mounted, hand held or tripod mounted. A 5-minute warm-up period is required for all specifications. OUTPUT FREQUENCY Direct Connect Testing: REPLY FREQUENCY The IFR 6015 may be directly connected to the UUT via a supplied RF coax cable via the RF I/O port. Range 962 to 1213 MHz Accuracy ± 10 kHz OUTPUT LEVEL ANTENNA PORT Range -67 to -2 dBm at Antenna port Resolution 1 dB Accuracy ± 2 dB Distance to UUT antenna 6 to 300 ft with supplied antenna Transit Case: The IFR 6015 is supplied in a rugged plastic transit case which provides stowage for the test set, directional antenna, RF coax cable, antenna shield, breakout box, and power supply/charger. RF I/O PORT Range -115 to -47 dBm Resolution 1 dB Accuracy -95 dBm to –47 dBm ± 1 dB Accuracy -115 dBm to <-95 dBm ± 2 dB REPLY PULSE SPACING P1 to P2 12 µs ± 100 ns (X Channel) @ 50% peak P1 to P2 30 µs ± 100 ns (Y Channel) @ 50% peak For the very latest specifications visit www.aeroflex.com REPLY PULSE WIDTH IDENT TONE P1/P2 Selection 3.5 µs ± 0.5 µs ECHO REPLY Control On/Off Position 30 nmi ± 1 nmi Amplitude -11 dB ± 1 dB relative to reply level REPLY PULSE RISE AND FALL TIMES ALL PULSES Rise Time 2.5 µs ± 0.25 µs (10% to 90%) Fall Time 2.5 µs ± 0.25 µs (90% to 10%) REPLY DELAY X CHANNEL Fixed Reply Delay 50 µs ± 100 ns Y CHANNEL Fixed Reply Delay 56 µs ± 100 ns RANGE DELAY X AND Y CHANNEL Range 0 to 450.00 nmi Resolution 0.01 nmi Accuracy ± 0.01 nmi RANGE RATE X AND Y CHANNEL Range 10 to 6500 kts Resolution 1 kts Accuracy ± 0.01% typical, tested to ± 0.5% SQUITTER PRF 2700 Hz Accuracy ± 2% Distribution Per ARINC 568 Selectable three letter code Frequency 1350 Hz Accuracy ± 2 Hz UUT MEASUREMENTS ERP Range +47 to +64 dBm Resolution 0.1 dB Accuracy ± 2 dB DIRECT CONNECTION PEAK PULSE POWER Range +47 to +64 dBm Resolution 0.1 dB Accuracy ± 1 dB FREQUENCY Range 1025.00 to 1150.00 MHz Resolution 10 kHz Accuracy ± 20 kHz INTERROGATION PULSE WIDTH P1 AND P2 PULSE WIDTHS Range 2.00 to 5.00 µs Resolution 1 ns Accuracy ± 50 ns INTERROGATION PULSE SPACING P1 to P2 Spacing 10 to 14 µs (X Channel) P1 to P2 Spacing 34 to 38 µs (Y Channel) Resolution 10 ns Accuracy ± 20 ns REPLY EFFICIENCY INTERROGATION PRF Range Range 0 to 100% Resolution 1% increments 1 to 300 Hz Resolution 1 Hz Accuracy Accuracy ± 0.5% ± 2 Hz TRANSPONDER MODE SPECIFICATIONS P1 to P4 SIGNAL GENERATOR MODE C RF OUTPUT FREQUENCY P1 to P3 10.00 µs ± 25 ns 21.00 µs ± 25 ns Interrogation Frequency P1 to P4 1030 MHz 23.00 µs ± 25 ns Accuracy INTERROGATION PULSE WIDTHS ± 10 kHz RF OUTPUT LEVEL MODE A,C,S,INTERMODE ANTENNA PORT P1,P2,P3 MTL + 6 dB typical, automatically controlled for a MTL range of -83 to -68 dBm Range 0.80 µs ± 50 ns MODE S P6 (Short DPSK Block) -67 to -2 dBm at antenna port Resolution 16.25 µs ± 50 ns P6 (Long DPSK Block) 0.5 dB 30.25 µs ± 50 ns Accuracy P5 ± 2 dB 0.80 µs ± 50 ns Distance to UUT antenna 6 to 200 ft with supplied antenna RF I/O PORT MTL + 6 dB typical, automatically controlled Range INTERMODE P4 (Short) 0.80 µs ± 50 ns P4 (Long) 1.60 µs ± 50 ns -115 to -47 dBm Resolution INTERROGATION PULSE RISE AND FALL TIMES ALL MODES 0.5 dB Rise Time Accuracy -95 to –47 dBm, ± 1 dB Accuracy -115 to <-95 dBm, ± 2 dB ATCRBS/MODE S INTERROGATION PULSE SPACING 50 to 100 ns Fall Time 50 to 200 ns PHASE MODULATION ALL MODES MODE A Transition Time P1 to P2 2.00 µs ± 25 ns P1 to P3 8.00 µs ± 25 ns ≤ 80 ns Phase Shift 180° ± 10° MODE C SLS LEVELS P1 to P2 ATCRBS 2.00 µs ± 25 ns P1 to P3 SLS Level (P2) -9 dB, -1 to +0 dB relative to P1 level 21.00 µs ± 25 ns MODE S 0 dB, -0 to +1 dB relative to P1 level Off P1 to P2 MODE S 2.00 µs ± 25 ns P1 to P6 SLS Level (P5) -12 dB, -1 to +0 dB relative to P6 level 3.50 µs ± 25 ns P1 to SPR +3 dB, -0 to +1 dB relative to P6 level Off 4.75 µs ± 25 ns P5 to SPR 0.40 µs ± 50 ns INTERMODE INTERROGATION PULSE SPACING MODE A Note: SLS level is automatically controlled in the SLS LEVEL test. INTERROGATION TEST SIGNALS MODE S PRF 50 Hz ± 5 Hz P1 to P3 8.00 µs ± 25 ns For the very latest specifications visit www.aeroflex.com ATCRBS REPLY DELAY JITTER PRF ATCRBS 235 Hz ± 5 Hz UUT MEASUREMENTS ERP (@ 1090 MHZ) Range + 45.5 to + 59 dBm (35.5 to 800 watts) Resolution 0.1 dB Accuracy ± 2 dB Direct Connection Peak Pulse Power (@1090 MHz) Range + 46.5 to + 59 dBm (45 to 800 watts) Resolution 0.1 dB Accuracy ± 1 dB TRANSMITTER FREQUENCY Range 1087.000 to 1093.000 MHz Resolution 10 kHz Accuracy ± 50 kHz RECEIVER SENSITIVITY, RADIATED MTL Range -67 to -79 dBm into 0 dBi antenna Resolution 0.1 dB Accuracy ± 2 dB, typical RECEIVER SENSITIVITY, DIRECT CONNECTION MTL Range -67 to -79 dBm Resolution 0.1 dB Accuracy ± 2 dB REPLY DELAY Range 0.00 to 2.30 µs Resolution 1 ns Accuracy ± 20 ns MODE S AND ATCRBS MODE S ALL-CALL Range 0.00 to 6.00 µs Resolution 1 ns Accuracy ± 20 ns PULSE SPACING F1 TO F2 Range 19.70 to 21.60 µs Resolution 1 ns Accuracy ± 20 ns MODE S PREAMBLE Range, P1 to P2 0.8 to 1.2 µs Range, P1 to P3 3.3 to 3.7 µs Range, P1 to P4 4.3 to 4.7 µs Resolution 1 ns Accuracy ± 20 ns PULSE WIDTHS F1 AND F2 Range 0.25 to 0.75 µs Resolution 1 ns Accuracy ± 20 ns ATCRBS MODE S PREAMBLE Range Range 1.80 to 7.00 µs Resolution 10 ns Accuracy ± 50 ns REPLY DELAY, MODE S AND ATCRBS MODE S ALL-CALL Range 125.00 to 131.00 µs Resolution 10 ns Accuracy ± 50 ns 0.25 to 0.75 µs Resolution 1 ns Accuracy ± 20 ns PULSE AMPLITUDE VARIATION Range, Mode S (Relative to P1) +3 to -3 dB Range, ATCRBS (Relative to F1) +3 to -3 dB Resolution 0.1 dB (0.01 dB via RCI) F1 to C1 Accuracy 1.45 µs ± 25 ns ± 0.5 dB DF 11 SQUITTER PERIOD F1 to A1 2.90 µs ± 25 ns Range 0.10 to 4.88 sec Resolution F1 to C2 4.35 µs ± 25 ns F1 to A2 10 ms 5.80 µs ± 25 ns Accuracy F1 to C4 ± 10 ms 7.25 µs ± 25 ns DIVERSITY ISOLATION F1 to A4 8.70 µs ± 25 ns Range 0 to >20 dB (Depending on Test Distance) F1 to B1 11.60 µs ± 25 ns Test Distance 1.83m (6ft) to 28.96m (95ft) F1 to D1 13.05 µs ± 25 ns Resolution F1 to B2 0.1 dB 14.50 µs ± 25 ns Accuracy F1 to D2 ± 3 dB TCAS MODE SPECIFICATIONS SIGNAL GENERATOR OUTPUT FREQUENCY REPLY FREQUENCY 1090 MHz 15.95 µs ± 25 ns F1 to B4 17.40 µs ± 25 ns F1 to D4 18.85 µs ± 25 ns MODE S P1 to P2 Accuracy 1.00 µs ± 25 ns ± 10 kHz P1 to P3 OUTPUT LEVEL (SIMULATED ERP) ANTENNA PORT Note 1 Radiated power at 0dBi UUT antenna -68 dBm typical @ 10 Nmi Range, automatically controlled Range -67 to -2 dBm at Antenna port Resolution 3.50 µs ± 25 ns P1 to P4 4.50 µs ± 25 ns P1 to D1 8.00 µs ± 25 ns D1 to Dn (n=2 to 112) 1.00 µs times (n-1) ± 25 ns REPLY PULSE WIDTHS 0.5 dB Accuracy MODE C ± 2 dB All Pulses Distance to UUT antenna 6 to 300 ft with supplied antenna RF I/O PORT Automatic mode -68 dBm @ 10 Nmi Range, automatically controlled Manual mode Range -115 to -47 dBm Resolution 0.45 µs ± 50 ns MODE S P1 through P4 0.50 µs ± 50 ns D1 through D112 0.50 µs ± 50 ns, 1 µs chip width Reply Modes TCAS I / II Mode C (with altitude reporting) 0.5 dB TCAS II Mode S formats 0, 11, 16 Accuracy E-TCAS Modes formats 0, 4, 5, 11, 16, 20, 21 -95 to –47 dBm, ± 1 dB Accuracy -115 to <-95 dBm, ± 2 dB REPLY PULSE SPACING MODE C REPLY PULSE AMPLITUDES ATCRBS ± 1 dB relative to F1 Mode S ± 1 dB relative to P1 F1 to F2 20.30 µs ± 25 ns For the very latest specifications visit www.aeroflex.com REPLY PULSE RISE AND FALL TIMES RECEIVER ALL MODES PULSE SPACING Rise Time ATCRBS (Mode C All Call) 50 to 100 ns Fall Time 50 to 200 ns PERCENT REPLY Range 0 to 100% Resolution 10% Accuracy ± 1% REPLY DELAY ATCRBS 3.0 µs ± 50 ns Mode S 128 µs ± 50 ns S1 to P1 ≤ ±200 ns Rejects ≥ ±1.0 us P1 to P3 Accepts Accepts ≥ ±1.0 us 23.0 us ≤ ±200 ns Rejects (<10% Replies) ≥ ±1.0 us Mode S P1 to P2 Accepts 2.0 us ≤ ±200 ns Rejects (<10% Replies) P1 to SPR Accepts Range ATCRBS (P2 or S1) ≥ ±1.0 us 4.75 us ≤ ±200 ns Rejects (<10% Replies) SUPPRESION Resolution 21.0 us ≤ ±200 ns Rejects (<10% Replies) P1 to P4 RANGE DELAY 0 to 260 nmi 2.0 us Accepts >0.5dB above level of P1 ≥ ±1.5 us <10% Replies UUT MEASUREMENTS 0.1 nmi Accuracy ± 0.02 nmi RANGE RATE Range -1200 to +1200 kts Resolution 10 kts Accuracy 10% ALTITUDE RANGE Range -1000 to 126,000 ft Resolution, Mode C 100 ft Resolution, Mode S 25 ft ALTITUDE RATE Range -10,000 to +10,000 fpm ERP (@1030MHZ) ATCRBS Range +43 to +58 dBm (20 to 631 watts) Resolution 0.1 dB Accuracy ± 2 dB MODE S Range +43 to +58 dBm (20 to 631 watts) Resolution 0.1 dB Accuracy ± 2 dB DIRECT CONNECTION PEAK PULSE POWER (@1030MHZ) ATCRBS Range +43 to +58 dBm (20 to 631 watts) Resolution Resolution 0.1 dB 100 fpm Accuracy Accuracy 10% SQUITTER Control On/Off Rate 0.8 to 1.2 seconds, randomly distributed ± 1 dB MODE S Range +43 to +58 dBm (20 to 631 watts) Resolution 0.1 dB Accuracy ± 1 dB FREQUENCY Aging ± 1 ppm per year Range 1029.900 to 1030.100 MHz Resolution Accuracy ± 1 ppm Test Limit 1 kHz ± 0.3 ppm Accuracy ± 10 kHz BATTERY TCAS BROADCAST INTERVAL Type Li Ion Range 1.0 to 12.0 sec Resolution Duration > 4 hrs continuous operation > 6 hrs, Typical 0.1 sec Accuracy INPUT POWER (TEST SET) ± 0.2 sec Input Range MISCELLANEOUS INPUT/OUTPUTS 11 VDC to 32 VDC Power Consumption RF I/O 55 W Maximum Type Input/Output Impedance 50 Ω typical Maximum Input Level 16 W Nominal at 18 VDC with charged battery Fuse Requirements 5 A, 32 VDC, Type F 4 kW peak INPUT POWER (SUPPLIED EXTERNAL AC TO DC CONVERTER) 10 W average Input Range VSWR 100 to 250 VAC, 1.5 A Max, 47-63 Hz < 1.3:1 Mains Supply Voltage Fluctuations ANTENNA ≤ 10% of the nominal voltage Type Transient Overvoltages Input/Output Impedance 50 Ω typical Maximum Input Level 10 W peak 1/2 W average VIDEO According to Installation Category II ENVIRONMENTAL (TEST SET) Use Pollution Degree 2 Altitude ≤ 4800 meters Operating Temperature Type NOTE 3 Output -20°C to 55°C Storage Temperature Impedance 50 Ω typical Generate Video Level 1.1 ± 0.4V peak to peak into 50 Ω Receive Video Level Proportional to IF level Baseline ± 0.5V referenced to ground TEST ANTENNA NOTE 4 -30°C to 71°C Relative Humidity 95% ±5% from 5° to 30°C 75% ±5% from 30° to 40°C 45% ±5% from 40° to 55°C ENVIRONMENTAL (SUPPLIED EXTERNAL AC TO DC CONVERTER) Use Indoors VSWR Altitude < 1.5:1 ≤ 10,000 meters Gain 6 dB, Typical TIME BASE (TCXO) Temperature Stability Operating Temperature 0° to 40°C Storage Temperature -20°C to 71°C ± 1 ppm For the very latest specifications visit www.aeroflex.com PHYSICAL CHARACTERISTICS Notes DIMENSIONS Height 11.2 inches (28.5 cm) Width 9.1 inches (23.1 cm) Depth 2.7 inches (6.9 cm) Weight (Test set only) < 8 lbs. (3.6 kg) NOTE 1 Simulates a 50.5 dBm XPDR ERP at 10 nMi range. NOTE 2 Level automatically controlled based on actual distance to UUT antenna. NOTE 3 Battery charging temperature range: 5°C to 40°C (controlled by internal charger). NOTE 4 Li Ion Battery must be removed below -20°C and above 60°C. NOTE 5 Temperature range extended to -20°C to 55°C. NOTE 6 Temperature range reduced to -30°C to 71°C. VERSIONS AND ACCESSORIES SUPPLEMENTAL INFORMATION When ordering please quote the full ordering number information. Test Set Certifications Altitude, operating Altitude, not operating Bench Handling Blowing Dust MIL-PRF-28800F MIL-PRF-28800F MIL-PRF-28800F MIL-STD-810F Drip-proof Explosive Atmosphere MIL-PRF-28800F MIL-STD-810F Relative Humidity Shock, Functional Vibration Limits Temp, operating NOTE 5 Temp, not operating NOTE 6 Transit Drop Safety Compliance MIL-PRF-28800F MIL-PRF-28800F MIL-PRF-28800F MIL-PRF-28800F MIL-PRF-28800F MIL-PRF-28800F UL-61010B-1 EN 61010-1 CSA 22.2 No 61010-1 EN 61326 EMC Class 2 Class 2 Class 2 Method 510.4, Procedure I Class 2 Method 511.4, Procedure 1 Class 2 Class 2 Class 2 Class 2 Class 2 Class 2 EXTERNAL AC-DC CONVERTER CERTIFICATIONS Safety Compliance EMI/RFI Compliance EMC UL 1950 DS CSA 22.2 No. 234 VDE EN 60 950 FCC Docket 20780 Curve “B” EN 61326 TRANSIT CASE CERTIFICATIONS Drop Test Falling Dart Impact Vibration, Loose Cargo Vibration, Sweep Simulated Rainfall FED-STD-101C ATA 300 FED-STD-101C ATA 300 MIL-STD-810F FED-STD-101C Immersion MIL-STD-810F Method 5007.1 Paragraph 6.3, Procedure A, Level A Category I Method 5019 Category I Method 506.4 Procedure II of 4.1.2 Method 5009.1 Sec 6.7.1 Method 512.4 Ordering Numbers 6015-110 6015-220 IFR 6015 Mode A/C/S Transponder, DME, TCAS/E-TCAS, TIS and TIS-B Ramp Test Set, with European Mains Leads 6015OPT3 ADS-B Extended Standard Warranties with Calibration for 6015 W6015/203C Extended standard warranty 36 months with scheduled calibration W6015/205C Extended standard warranty 60 months with scheduled calibration Accessories for 6015 AC0820 Desk Top Stand AC0826 Tripod AC0825CD IFR 6015 Operation Manual - CD AC24006 Tripod, Dolly, Stand EXPORT CONTROL: This product is controlled for export under the International Traffic in Arms Regulations (ITAR). A license from the U.S. Department of State is required prior to the export of this product from the United States. EXPORT WARNING: Aeroflex's military products are controlled for export under the International Traffic in Arms Regulations (ITAR) and may not be sold or proposed or offered for sale to certain countries including: Belarus, Burma, China, Cuba, Haiti, Iran, Liberia, Libya, North Korea, Somalia, Syria, Sudan, and Vietnam. See ITAR 126.1 for complete information. FINLAND Tel: [+358] (9) 2709 5541 Fax: [+358] (9) 804 2441 INDIA Tel: [+91] 80 5115 4501 Fax: [+91] 80 5115 4502 SPAIN Tel: [+34] (91) 640 11 34 Fax: [+34] (91) 640 06 40 FRANCE Tel: [+33] 1 60 79 96 00 Fax: [+33] 1 60 77 69 22 KOREA Tel: [+82] (2) 3424 2719 Fax: [+82] (2) 3424 8620 UK Burnham Tel: [+44] (0) 1628 604455 Fax: [+44] (0) 1628 662017 GERMANY Tel: [+49] 8131 2926-0 Fax: [+49] 8131 2926-130 SCANDINAVIA Tel: [+45] 9614 0045 Fax: [+45] 9614 0047 UK Cambridge Tel: [+44] (0) 1763 262277 Fax: [+44] (0) 1763 285353 As we are always seeking to improve our products, the information in this document gives only a general indication of the product capacity, performance and suitability, none of which shall form part of any contract. We reserve the right to make design changes without notice. All trademarks are acknowledged. Parent company Aeroflex, Inc. ©Aeroflex 2006. Versions IFR 6015 Mode A/C/S Transponder, DME, TCAS/E-TCAS, TIS and TIS-B Ramp Test Set, with US Mains Leads UK Stevenage Tel: [+44] (0) 1438 742200 Fax: [+44] (0) 1438 727601 Freephone: 0800 282388 USA Tel: [+1] (316) 522 4981 Fax: [+1] (316) 522 1360 Toll Free: 800 835 2352 w w w.aeroflex.com [email protected] Our passion for performance is defined by three attributes represented by these three icons: solution-minded, performance-driven and customer-focused. Part No. 46891/263, Issue 1, 01/06