AMETHERM NT0510052

DATA SHEET
Part Number: NT05 10052
Ordering Different Lead Types:
Inside Kinked Leads
Outside Kinked Leads
Use -A after Ametherm’s part #
Not Available
For example: to order an inside kinked lead use part number NT05 10052-A
D
D
D
T
C
B
L
S
S
S
STRAIGHT
LEADS
OUTSIDE
KINKED LEADS
INSIDE
KINKED LEADS
Electrical Specifications:
Zero-Power Resistance @ 25°C
Resistance @ 0°C/ Resistance @ 50°C
Resistance @ 25°C/ Resistance @ 125°C
Beta
Temp Coefficient of Resistance @ 25°C
Operating Temperature Range
Dissipation Constant
Thermal Time Constant
Mechanical Specifications:
10.0 Ω ± 10%
5.1 ± 2%
12.9 ± 2%
2980 ± 2%
-3.19%/°C
-50°C/150°C
5.0mW/°C
10.0 Seconds
D
T
Lead Diameter
S
L
Straight Leads
5.6 mm Max
3.0 mm Max
0.5 mm Nom
2.5 mm Nom
38.0 mm Min
Standard
Resistance Temperature Curve:
Temperature
-50
-40
-30
-20
-10
R@T/R@25°C
24.23
14.36
8.90
5.65
3.62
Temperature
0
25
50
75
100
125
R@T/R@25°C
2.42
1.000
0.465
0.240
0.138
0.0801
Revision Date: March 19, 2003
Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701
Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670
www.ametherm.com