DATA SHEET Part Number: SL10 10002 Ordering Different Lead Types: Inside Kinked Leads Outside Kinked Leads Use -A after Ametherm’s part # Use -B after Ametherm’s part # For example: to order an inside kinked lead use part number SL10 10002-A D D D T C B L S S S STRAIGHT LEADS OUTSIDE KINKED LEADS INSIDE KINKED LEADS Electrical Specifications: Mechanical Specifications: Resistance @ 25°C Max Steady State Current Up to 65°C Max Recommended Energy Rating (J)/ Max Vac Rating Actual Failure Point of Instantaneous Energy (Joules) Resistance @ 100% of Max Current Resistance @ 50% of Max Current Body Temperature @ 100% Current Rating Dissipation Constant Thermal Time Constant Material Type Max Recommended Capacitance @ 120VAC/250VAC 10.0 Ω ± 25% 2.0 A 10.0 J/ 250 30.0 J 0.340 Ω 0.600 Ω 124 °C 9.4mW/°C 20 seconds “C” 700µF/ 135µF CSA File Number: #CA118061 D T Lead Diameter S L Straight Lead Coating Run Down B C 9.40 ± 0.5 mm 4.30 ± 0.5 mm 0.8 ± 0.03 mm 5.10 ± 0.3 mm 38.0 ± 9.0 mm 5.0 ± 1.0 mm 5.6 ± 0.55 mm 2.54 ± 1.0 mm Revision Date: November 19, 2004 Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701 Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670 www.ametherm.com