DATA SHEET Part Number: SL12 12004 Ordering Different Lead Types: Inside Kinked Leads Outside Kinked Leads Use -A after Ametherm’s part # Use -B after Ametherm’s part # For example: to order an inside kinked lead use part number D D SL12 12004-A D T C B L S S S STRAIGHT LEADS OUTSIDE KINKED LEADS INSIDE KINKED LEADS Electrical Specifications: Mechanical Specifications: Resistance @ 25°C Max Steady State Current Up to 65°C Max Recommended Energy Rating (Joules) Actual Failure Point of Instantaneous Energy (Joules) Resistance @ 100% of Max Current Resistance @ 50% of Max Current Body Temperature @ 100% Current Rating Dissipation Constant Thermal Time Constant Material Type Max Recommended Voltage Max Recommended Capacitance @ 120VAC/240VAC 12.0 Ω ± 10% 4.0 A 40.0 J 90.0 J 0.220 Ω 0.510 Ω 139 °C 12.7mW/°C 42 seconds “C” 265Vrms 2700µF/690µF CSA File Number: #CA118061 Rev. A D T Lead Diameter S L Straight Leads Coating Run Down B C 6.35 ± 0.60 mm 3.00 ± 0.5 mm Revision Date: September 19, 2006 Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701 Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670 www.ametherm.com 11.5 ± 1.0 mm 8.9 mm Max 0.8 ± 0.1 mm 8.0 ± 0.50 mm 38.0 ± 9.0 mm 5.0 ± 1.0 mm