ANADIGICS 13LED20-1XX

13LED20
1300nm Surface Emitting LED
FEATURES
•
Planar Structure
•
Dielectric Passivation
•
100% Purge Burn-in
APPLICATIONS
•
Optical Data Communications Systems
•
E1 / T1 Communication Systems
•
Analog Transmission Systems
13LED20-1xx
TO can Package
13LED20-5xx
FC Receptacle
PRODUCT DESCRIPTION
The 13LED20 is a 1300nm surface emitting
LED. It is intended for use in low cost, short
haul
multi-mode optical communication
systems operating to 100MB/s and for use in
optical test and measurement equipment.
The device can be assembled in a TO can or
mounted in an SC, ST or FC receptacle.
Custom packages are an option.
ELECTRICAL CHARACTERISTICS
Table 1: Electrical Specifications
PARAMETER
Total output power
Minimum coupled power (1)
Peak wavelength
Spectral width
Rise / Fall time
(1) Coupled to 62.5/125 fiber @ 100mA forward current
MIN
30
1260
-
TYP
1
1300
120
6
MAX
1340
-
UNIT
mW
μW
nm
nm
ns
Table 2: Absolute Maximum Ratings
PARAMETER
MIN
MAX
UNIT
Forward Current
125
mA
Operating Case Temperature
-40
+85
ºC
Storage Temperature
-40
+85
ºC
Soldering temperature (10 seconds)
+250
ºC
Stresses in excess of the absolute ratings may cause permanent damage. Functional operation
is not implied under these conditions. Exposure to absolute ratings for extended periods of time
may adversely affect reliability.
PD075
ORDERING INFORMATION
Part Number
13LED20-1xx
13LED20-5xx
Options
Package: TO46
Number of pins: 2, 3
Cap: Window, lens. AR / Non-AR coated.
Cap plating: Gold or nickel
Number of pins: 2, 3
Connector Type: SC, ST or FC. Aligned for APC or UPC
Please contact Anadigics for the specific part number and pinout that suits your needs
ANADIGICS, Inc.
829 Flynn Road
Camarillo, California 93012, U.S.A.
Tel: +1 (805) 445-4500
Fax: +1 (805) 445-4502
URL: http://www.anadigics.com
E-mail: [email protected]
IMPORTANT NOTICE
ANADIGICS, Inc. reserves the right to make changes to its products or discontinue any product at any
time without notice. The product specifications contained in Advanced Product Information sheets and
Preliminary Data sheets are subject to change prior to a product’s formal introduction. Information in
Data Sheets have been carefully checked and are assumed to be reliable; however, ANADIGICS
assumes no responsibility for inaccuracies. ANADIGICS strongly urges customers to verify that the
information they are using is current before placing orders.
WARNING
ANADIGICS products are not intended for use in life support appliances, devices, or systems. Use of
an ANADIGICS product in any such application without written consent is prohibited.
Rev 1.0
2