20 Watts APA06 APA04 - Boost Total Power: Input Voltages: No. of Outputs: 20 Watts 3.3V, 5V Single Electrical Specs Input Input range 3.0 to 5.5V (Buck) 3.0 to 4.0V (Boost) Efficiency 90% (5/3.3) , 83% (1.8V) Output Special Features • • • • • • • Excellent for POL Applications High Efficiency - Non Isolated 3.3V and 5V input, Standard SIP package 2.5 X .55 X .31” Enable and Trim Function Overcurrent Protection Sense Pins Voltage tolerance Line regulation Load regulation ± 1.0% ± 0.5% ± 0.5% Noise/ripple Short circuit protection Transient response 50mV P-P Auto-recovery 4%Vo, 200us Temperature Regulation ±0.02 %Vo/°C Switching frequency 430kHz typ Temperature coefficient ± 0.03%Vo/° C Isolation Non Isolated Environmental Operating ambient temperature: 25°C to 55°C (full load, 200LFM) - Storage temperature: -40°C to +125°C MTBF: =7,000,000 hours (Bellcore TR332, Ta=25°C) Weight: = 7.5 grams max Safety 4 UL CSA UL 1950 Recognized CAN22.2-950 Recognized TUV EN60950 Certified North America (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662 rev 01.14.03 AMERICAS EUROPE ASIA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 APA06/04 Ordering Information Input Voltage Output Voltage Efficiency Model Number Buck 3.0-5.5 V 3.0-5.5 V 3.0-5.5 V 3.0-5.5 V 1.2V @ 6.0 A 1.5V @ 6.0 A 1.8V @ 6.0 A 2.1V @ 6.0 A 80% 81% 83% 86% APA06K04 APA06M04 APA06Y04 APA06D04 4.5-5.5 V 4.5-5.5 V 2.5V @ 6.0 A 3.3V @ 6.0 A 87% 90% APA06G05 APA06F05 Boost 3.3-4.0 V 5.0V @ 4.0 A 89% APA04A03 Notes: 1. Add -E to eliminate Sense and Power Good feature 2. Right Angle Pins Available APA04 ( Boost ) Pinout APA06 ( Buck ) Pinout Notes: 1. Recommended Input Filter - 220uF Electrolytic Cap in parallel with 2.2uF Ceramic Cap Vin+ to GND 2. Recommended Output Filter - 2.2uF Ceramic Cap in parallel with 1000uF Electrolytic Cap (Vout+ to GND) 3. 20 MHz bandwidth. An external 0.1 uf ceramic capacitor is recommended to be placed from +V out to comm. 4. All specifications are typical at nominal line, full load, and 25°C unless otherwise noted. 5. All specifications subject to change without notice. 6. Mechanical drawings are for reference only. www.astec.com 5