ASTRODYNE MTCC-5011

MCA-5
5 W U l t r a m i n i a t u re Modular Switching Power Supplies
series
Single / Dual / Triple Outputs
Universal 85VAC to 265VAC Input
3.3VDC to 24VDC Outputs
3,000VAC Input to Output Isolation
PCB and Chassis Mount Packages
Full Safety Approvals
PCB 2.28”L x 1.77”W x 0.83”H
Chassis 3.77”L x 2.16”W x 1.0”H
Model Number
Output Voltage
Output Amps
Output Watts
SINGLE OUTPUT - PCB Mount
MSCA-5000
3.3 VDC
MSCA-5001
5 VDC
MSCA-5002
12 VDC
MSCA-5003
15 VDC
MSCA-5005
24 VDC
1.25
1
0.42
0.33
0.23
4W
5W
5W
5W
5W
SINGLE OUTPUT - Chassis Mount
MSCC-5000
3.3 VDC
MSCC-5001
5 VDC
MSCC-5002
12 VDC
MSCC-5003
15 VDC
MSCC-5005
24 VDC
1.25
1
0.42
0.33
0.23
4W
5W
5W
5W
5W
SINGLE OUTPUT - DIN Rail Mount
MSCC-5000/DRL
3.3 VDC
MSCC-5001/DRL
5 VDC
MSCC-5002/DRL
12 VDC
MSCC-5003/DRL
15 VDC
MSCC-5005/DRL
24 VDC
1.25
1
0.42
0.33
0.23
4W
5W
5W
5W
5W
Order On-Line!
WWW.ASTRODYNE.COM
astrodyne.com
Fully Approved
UL/CSA22.2 60950-1 File# E167432
EN60950 File# B021022749042
IEC60950-1 File# DE354108
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
MCA-5
5 W U l t r a m i n i a t u re Modular Switching Power Supplies
series
Single / Dual / Triple Outputs
Universal 85VAC to 265VAC Input
3.3VDC to 24VDC Outputs
3,000VAC Input to Output Isolation
PCB and Chassis Mount Packages
Full Safety Approvals
PCB 2.28”L x 1.77”W x 0.83”H
Chassis 3.77”L x 2.16”W x 1.0”H
Model Number
Output Voltage
Output Amps
Output Watts
DUAL OUTPUT - PCB Mount
MDCA-5006
+/-12 VDC
MDCA-5007
+/-15 VDC
+/-0.21
+/-0.17
5W
5W
DUAL OUTPUT - Chassis Mount
MDCC-5006
+/-12 VDC
MDCC-5007
+/-15 VDC
+/-0.21
+/-0.17
5W
5W
DUAL OUTPUT - DIN Rail Mount
MDCC-5006/DRL
+/-12 VDC
MDCC-5007/DRL
+/-15 VDC
+/-0.21
+/-0.17
5W
5W
TRIPLE OUTPUT - PCB Mount
MTCA-5009
+5,+/-12 VDC
MTCA-5011
+5,+/-15 VDC
0.6,0.1/0.1
0.45,0.1/0.1
5W
5W
TRIPLE OUTPUT - Chassis Mount
MTCC-5009
+5,+/-12 VDC
0.6,0.1/0.1
MTCC-5011
+5,+/-15 VDC
0.45,0.1/0.1
5W
5W
TRIPLE OUTPUT - DIN Rail Mount
MTCC-5009/DRL
+5,+/-12 VDC
0.6,0.1/0.1
MTCC-5011/DRL
+5,+/-15 VDC
0.45,0.1/0.1
5W
5W
Order On-Line!
WWW.ASTRODYNE.COM
astrodyne.com
Fully Approved
UL/CSA22.2 60950-1 File# E167432
EN60950 File# B021022749042
IEC60950-1 File# DE34108
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
MCA-5
5 W U l t r a m i n i a t u re Modular Switching Power Supplies
INPUT SPECIFICATIONS
Input Voltage, Nominal
Input Frequency
Inrush Current
GENERAL SPECIFICATIONS
85-265VAC
Nominal: 100-240VAC
47-440 Hz, 50-60Hz Nom.
20A @ 100VAC, typ
40A @ 200VAC, typ
OUTPUT SPECIFICATIONS
Output Voltage/Current
Initial Accuracy
Voltage Adjust
Load Regulation (20%-FL)
Line Regulation
Temperature Coefficient
Ripple/Noise(20Mhz BW)
Overvoltage Protection
Hold Up Time
Short Circuit Protection
Current Limit
series
See Specific Model
+/-1%, adjustable
+/-6%, typ
+/-0.3%, typ
+/-0.3%, typ
+/-0.03%/°C
150mV Pk-Pk, typ
Clamp, 130-150% *
30mS, typ
Continuous, self-recovering *
130% typ,Self-Reset Foldback On/Off Control
Input-Out Isolation
Output-Ground Isolation
Input-Ground Isolation
Operating Frequency
Efficiency (@ Full Load)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Relative Humidity
Storage Temperature
MTBF, Single/Multi Output
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
0 to +50°C FL See Derate *
(Free-air Convection) 0-95%, Non-Condensing
-25 to +71°C *
180,000 Hrs/110,000 Hrs
Mil Std 217, 25C
PHYSICAL SPECIFICATIONS
Case Material
Construction
Weight PCB / CHA
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
Open Collector
Logic “1”/Open=ON
Logic “0”/GND=OFF
3000VAC
1000VAC
2500VAC
140 Khz, fixed
75 - 80%, typ
Rynite, 94V-0 Rated
Encapsulated, Soft Pot
4 oz (112g) / 8.5 oz (238g)
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
MCA-5
5 W U l t r a m i n i a t u re Modular Switching Power Supplies
series
PERFORMANCE CURVES
100
90
90
80
80
Typical Efficiency, %
Output Current, %
70
60
50
40
30
20
70
60
50
10
0
40
-10
0
10
20
30
40
50
60
70
10
25
50
75
100
% of Full Load
Ambient Temp., DegC
MECHANICAL DIMENSIONS - PCB MOUNT
1.85 [47.00]
Adjustment Pot
Power “Good” Indicator
0.040 [1.02] DIA. TYP.
1.77 [45.0]
2.28 [57.9]
0.83 [21.0]
0.20 [5.1]
Tolerance:
.XX ± 0.02 [0.508]
.XXX ± 0.01 [0.253]
Dimensions shown in inch [mm]
0.12 [5.3]
1.85 [47.0]
WWW.ASTRODYNE.COM
Model
Type / Pin#
Single Dual
1
2
3
4
5
6
7
8
9
10
AC HI
AC LO
GND
No Pin
No Pin
+Vout
No Pin
No Pin
-Vout
Ctrl
Triple
AC HI AC HI
AC LO AC LO
GND
GND
No Pin +Vout
No Pin Out Com
+Vout No Pin
No Pin -Vout
Out Com+5Vout
-Vout 5V Ret
Ctrl
Ctrl
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
MCA-5
5 W U l t r a m i n i a t u re Modular Switching Power Supplies
series
MECHANICAL DIMENSIONS - CHASSIS MOUNT
4
1
5
6
2
7
8
3
MECHANICAL DIMENSIONS - DIN Rail
0.350 [8.89]
9
Model
Match
Type / Pin#
Single Dual
Unmatch
Dual
Triple
1
2
3
4
5
6
7
8
9
AC LO
GND
AC HI
Ctrl
Com
Com
+5Vout
+12Vout
N/C
AC LO
GND
AC HI
Ctrl
+5 Ret
+5Vout
-Vout
+/- Com
+Vout
AC LO
GND
AC HI
Ctrl
-Vout
-Vout
+Vout
+Vout
N/C
AC LO
GND
AC HI
Ctrl
-Vout
Com
Com
+Vout
N/C
DIN Rail mounting kit available for Chassis-mount modules, specify part #
M-DRL-01. Kit includes mounting plate, DIN Rail cliip and assembly hardware.
0.100 [2.54]
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181