AURIS TC-206B

Quartz SMD
TC206B
Features:
- Cylindrical enclosures with mounting clips
- Surface mount pick & place
- High performance/cost ratio
Specifications
Symbol
f
Frequency range
Frequency tolerance,Ta=25°C
Load capacitance
Temp. coefficient
Temperature range
TC-206B
32.768kHz
32kHz ~ 200kHz
± 20ppm ~ ± 100ppm
6pF ~ 12.5pF (Std.)
Df/f
CL
Remarks
Standard
Available
Others are offered
Please specify
Max
-0.04 x 10-6 / °C²
-20°C - +70°C ~ -40°C - +85°C
Storage temperature
A
TSTG
Operating temperature
TOPR
-55°C ~ +125°C
Maximum drive level
MDL
Recommended drive level
RDL
1mW
-
Series resistance
R1
40k Ohm max
Shunt capacitance
C0
1.3pF
Typ
Insulation resistance
Aging
IR
500M Ohm
± 5ppm/Year
Min
Max
Drive level
DfA
Resistance of series resonance (ESR)
Frequency (MHz)
Mode
3.579 <= f < 6.0
Fundamental
6.0 <= f < 10.0
Fundamental
10.0 <= f < 15.0
Fundamental
Ohm max
150
100
60
Frequency (MHz)
15.0 <= f < 35.0
30.0 <= f < 90.0
Standard
Max
As per table (25°C)
Mode
Fundamental
3rd OT
Ohm max
40
70
Drawing
TC206B
Dimensions in mm
Order key
Q
Part
Q=Quartz
- 32.768000k - TC206B
Frequency
k=kHz
Package
TC206B
- 50
-B
- 12.5
- X
Frequency
Temperature
Load
tolerance
range
capacitance
+/-ppm
A=
pF
(25°C)
B=-10°C ~ 60°C
0°C ~ 70°C
Option
X=Special options
SR=series
C=-10°C ~ 70°C
D=-20°C ~ 70°C
E=-40°C ~ 85°C
H=-20°C ~ +80°C
I=-10°C ~ +50°C
Remarks: All specifications subject to change without notice!