BEL 07LC

ISOLATED DC/DC CONVERTERS
48V Input 3.3V/7A or 5V/5A or 12V/2.5A Output
07LC-25T Series
•
Compact Through-hole Package
•
Remote On/Off
•
Excellent Thermal Performance
•
Output Voltage Trim
•
1500V Isolation
•
Input Under Voltage Lockout
•
High Efficiency
•
Over Voltage Protection
•
High Power Density
•
SCP/OCP
•
Wide Input Voltage
•
Over Temperature Protection
Description
The 07LC-25Txx0 series converters are isolated DC/DC converters that operate from a nominal 48V source.
These converters provide up to 25W of output power. These units are designed to be high efficient and very low
cost. Features include remote on/off, output adjust, short circuit protection, over current protection, overtemperature protection, and input under voltage lockout. These converters are provided in a compact, throughhole package that is easy to use and provides good thermal performance, and are pin-to-pin compatible with the
Emerson AG25 Series.
Part Selection
Output
Voltage
12.0V
5.0V
3.3V
Input Voltage
36 – 75V
36 – 75V
36 – 75V
Max. Output
Current
2.5A
5A
7A
Max. Output
Power
30.0W
25.0W
23.0W
Typical
Efficiency
90%
90%
88%
Model Number
07LC-25T120
07LC-25T050
07LC-25T033
Note: Add “G” suffix at the end of the model number to indicate Tray Packaging.
Absolute Maximum Ratings
Parameter
Input Voltage (continuous)
Remote On/Off
Ambient Temperature
Storage Temperature
Min
-0.3V
-0.3V
-40°C
-55°C
Typ
-
Max
80V
12V
85°C
125°C
Notes
Input Specifications
Parameter
Input Voltage
Input Current (no load)
Input Current (full load)
Remote Off Input Current
Input Reflected Ripple Current
(RMS)
Input Reflected Ripple Current
(pk-pk)
I2t Inrush Current Transient
Min
36V
-
Typ
25mA
3mA
Max
75V
40mA
1.1A
10mA
-
10mA
20mA
-
40mA
-
0.0012A s
0.0024A2s
Turn-on Input Voltage
31V
34V
36V
Turn-off Input Voltage
30V
33V
35V
60mA
2
Notes
Tested with simulated source impedance of
10uH, 5Hz to 20MHz and a 100uF/100V
electrolytic capacitor with ESR=1 ohm max,
at 200KHz
Note: All specifications are typical at 25°C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input 3.3V/7A or 5V/5A or 12V/2.5A Output
Output Specifications
Parameter
Output Voltage Set Point
Min
Typ
Max
VO=3.3V
VO=5.0V
VO=12.0V
3.234 V
4.900V
11.760V
3.3 V
5.0 V
12.0V
3.366 V
5.100V
12.240V
VO=3.3V
VO=5.0V
VO=12.0V
-
1mV
2mV
5mV
3mV
5mV
10mV
VO=3.3V
VO=5.0V
VO=12.0V
Temperature Regulation (-40°C to +85°C)
VO=3.3V
VO=5.0V
VO=12.0V
-
2mV
4mV
9mV
5mV
8mV
18mV
-
30mV
40mV
100mV
50mV
70mV
170mV
Ripple and Noise (RMS)
-
10mV
20mV
Ripple and Noise (pk-pk)
-
40mV
75mV
VO=3.3V
VO=5.0V
VO=12.0V
0A
0A
0A
-
7A
5A
2.5A
VO=3.3V
VO=5.0V
VO=12.0V
7.7A
5.5A
3A
-
0.5A2s
12A
8A
4.2A
1A2s
Turn on Time
-
10mS
25mS
Overshoot at Turn On
Output Capacitance
-
0%
5%
0uF
0uF
0uF
-
3300uF
2200uF
330uF
-
75mV
100mV
-
150uS
200uS
-
75mV
100mV
Notes
Test condition: Vin=48V,
IO=50% full load
Line Regulation
Load Regulation
Tested with 0-20MHz BW, with
a 0.47uF ceramic capacitor at
the output
Output Current
Current Limit Threshold
Short Circuit Surge Transient
VO=3.3V
VO=5.0V
VO=12.0V
-
Transient Response
50% ~ 75%
Max Load
50% ~ 25%
Max Load
50% ~ 75%
Max Load
50% ~ 25%
Max Load
Overshoot
Settling Time
Overshoot
Vo=3.3V
Settling Time
-
150uS
200uS
Overshoot
-
100mV
150mV
Settling Time
Overshoot
Vo=5.0V
-
150uS
200uS
-
100mV
150mV
Settling Time
-
150uS
200uS
Overshoot
-
150mV
200mV
-
150mV
200mV
-
150mV
200mV
-
150mV
200mV
50% ~ 75%
Max Load
Settling Time
50% ~ 25%
Max Load
Settling Time
Overshoot
Vo=12.0V
Tested conditions:
di/dt=0.1A/uS, Vin=48V,
Ta=25°C, with a 220uF/10V
electrolytic capacitor at the
output.
Note: All specifications are typical at 25°C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input 3.3V/7A or 5V/5A or 12V/2.5A Output
General Specifications
Parameter
Min
Typ
Max
Notes
85%
87%
87%
88%
90%
90%
-
Switching Frequency
200kHz
230kHz
260kHz
Output Trim Range
90% VO
-
110% VO
I/O Isolation Voltage
1500V
-
-
Isolation Capacitance
-
1500pF
-
90%
-
110%
-
110°C
-
3.9V
5.7V
13.6V
-
5V
7V
14.2V
Efficiency
VO=3.3V
VO=5.0V
VO=12.0V
Output Voltage Trim Range
Over Temperature Protection
Measured at Vin=48V, IO=Io, max
Over Voltage Protection
VO=3.3V
VO=5.0V
VO=12.0V
MTBF
Calculated Per Bell Core TR-332 (IO =
IOmax; Ta = 25°C)
2,602,427 hours
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Weight
2.0 x 1.0 x 0.438
50.8 x 25.4 x 11.14
-
20g
-
Note: All specifications are typical at 25°C unless otherwise stated.
Control Specifications
Parameter
Min
Typ
Max
-0.3V
-
0.8V
3.5V
-
12V
-0.3V
-
0.8V
3.5V
-
12V
0.3mA
-
0.75mA
Notes
Remote On/Off
Signal Low (Unit On)
Signal High (Unit Off)
Signal Low (Unit Off)
Signal High (Unit On)
Current Sink
Active Low
Active High
The remote On/Off pin open,
Unit On.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input 3.3V/7A or 5V/5A or 12V/2.5A Output
Output Trim Equations
Equations for calculating the trim resistor (in kΩ) given the desired adjusted voltage (Vadj) and the nominal
output voltage of the converter (Vnom) are shown below. The Trim Down resistor should be connected between
the Trim pin and Vout. The Trim Up resistor should be connected between the Trim pin and Ground. Only one of
the resistors should be used for any given application.
Vout
Rtrimdown
Rtrimup =
Rtrimdown
A
=
−B
Vnom − Vadj
Vadj
Module
Trim
GND
Vout
C
−D
− Vnom
Module
Trim
Rtrimup
GND
Vnom
A
B
C
D
12
53.320
9.260
14.025
3.650
5
19.300
15.120
6.350
10.000
3.3
21.711
40.610
13.032
30.100
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input 3.3V/7A or 5V/5A or 12V/2.5A Output
Efficiency Data
90%
75%
36V
70%
48V
65%
75V
EFFICIENCY
80%
60%
55%
50%
0.7A
1.75A
3.5A
5.25A
7A
95%
90%
85%
80%
75%
70%
65%
60%
55%
50%
0.5A
36
48
75
1.25A
2.5A
3.75A
OUTPUT CURRENT (A)
OUTPUT CURRENT (A)
07LC-25T033
07LC-25T050
EFFICIENCY
EFFICIENCY
85%
95%
90%
85%
80%
75%
70%
65%
60%
55%
50%
0.25A
5A
36
48
75
0.625A
1.25A
1.875A
2.5A
OUTPUT CURRENT (A)
07LC-25T120
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input 3.3V/7A or 5V/5A or 12V/2.5A Output
Thermal Derating Curves
07LC-25T033
07LC-25T050
07LC-25T120
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48V Input 3.3V/7A or 5V/5A or 12V/2.5A Output
Pin Connections
Pin
Function
1
Vin+
2
Vin-
3
Remote On/Off
4
Vo+
5
Vo-
6
Trim
©2004 Bel Fuse Inc. Specifications subject to change without notice. 120704
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com