BEL 2664G

HIGH FREQUENCY MAGNETICS
Specialty Through Hole Transformer
TM00102
•
Operates as pulse transformer
•
Operating temperature range: -40°C to +85° C
•
Operates as analog transformer
•
Meets IEC 695, 2-2 flammability requirements
•
Can be configured as 1 : 1 or 1 : 2CT isolation
transformer
•
PWB Process Capability: standard printed wiring board
assembly techniques, total-immersion cleaning
•
Can be configured as 1 : 3 auto transformer
•
Reliability testing: Shock, vibration, temperature cycling,
temperature - humidity - bias
ELECTRICAL SPECIFICATIONS AT 25° C
Turns Ratio
± 3%
Part Number
2664G
DCR
Leakage
Inductance2
µH max
Ω
Inductance1
µH min
max
(4-6) : (3-8) : (7-1)
(4-6)
(3-8)
(4-6)
(7-1)
(4-6)
1:1:1
120
0.3
0.3
0.3
0.31
Interwinding
Capacitance
pF max
Minimum
Interwinding
Breakdown
Voltage
Vrms
30
100
1. measured at 100 kHz, 0.013 Vac
2. measured at 100 kHz
SCHEMATIC
2664G
4
6
3
8
7
1
©2000 Bel Fuse Inc. Specifications subject to change without notice. 09.00
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
T1-5
HIGH FREQUENCY MAGNETICS
Specialty Through Hole Transformer
TM00102
MECHANICAL
2664G
0.50
(12.7)
MAX
0.40
(10.16)
MAX
TERMINAL 1 IDENTIFIER
0.31
(7.87)
MAX
0.110 (2.79)
±0.010 (0.25)
0.100
(2.54)
0.023 (0.58) SQ TYP (PHOSPHOR
BRONZE, SOLDER COATED)
1 2
3
4
0.250
(6.35)
8
7
6
5
Unless otherwise specified, dimensions are nominal and in inches (millimeters).
©2000 Bel Fuse Inc. Specifications subject to change without notice. 09.00
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
198 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F / 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com
T1-6