LASER DIODE NX5315EH 1 310 nm FOR FTTH PON APPLICATION InGaAsP MQW-FP LASER DIODE DESCRIPTION The NX5315EH is a 1 310 nm Multiple Quantum Well (MQW) structured Fabry-Perot (FP) laser diode with InGaAs monitor PIN-PD. This device is designed for application up to 1.25 Gb/s. APPLICATION • FTTH PON (B-PON, G-PON, GE-PON 10 km) system FEATURES • Optical output power Po = 13.0 mW • Low threshold current lth = 6 mA • Differential Efficiency ηd = 0.5 W/A • Wide operating temperature range TC = −40 to +85°C • InGaAs monitor PIN-PD • CAN package φ 5.6 mm • Focal point 6.35 mm Document No. PL10531EJ03V0DS (3rd edition) Date Published July 2006 NS CP(K) The mark <R> shows major revised points. The revised points can be easily searched by copying an "<R>" in the PDF file and specifying it in the "Find what:" field. NX5315EH PACKAGE DIMENSIONS (UNIT: mm) 1.0±0.1 110˚±2˚ 1 2 *1 Focal Point ∆x = ±300 µ m MAX. ∆y = ±300 µ m MAX. 2.97±0.2 6.35±0.5 φ 2.0 PIN CONNECTIONS 1 (Case) Reference Plane LD 4 2 4– φ 0.45 φ 2.0 *1 Focal Point: A point to get maximum optical output power from fiber. *2 ( ) indicates nominal dimension. 2 4 3 (0.3)*2 3.87±0.3 BOTTOM VIEW (0.3)*2 φ 5.6+0.00 –0.03 (φ 4.2)*2 (φ 3.55)*2 15.0±1.0 1.2±0.1 <R> Data Sheet PL10531EJ03V0DS PD 3 NX5315EH ORDERING INFORMATION Part Number NX5315EH-AZ* Package Pin Connections 1 4-pin CAN with ball lens cap LD 4 2 PD 3 Remarks 1. The color of ball lens cap might be observed differently. 2. The hermetic test will be performed as AQL 1.0%. *NOTE: Please refer to the last page of this data sheet, “Compliance with EU Directives” for Pb-Free RoHS Compliance Information. Data Sheet PL10531EJ03V0DS 3 NX5315EH ABSOLUTE MAXIMUM RATINGS Parameter Symbol Ratings Unit Optical Output Power Po 20 mW Forward Current of LD IF 150 mA Reverse Voltage of LD VR 2.0 V Forward Current of PD IF 10 mA Reverse Voltage of PD VR 20 V Operating Case Temperature TC −40 to +85 °C Storage Temperature Tstg −40 to +85 °C Assembly Temperature Tasb 150 (15 Hr) °C Lead Soldering Temperature Tsld 350 (3 sec.) °C Relative Humidity (noncondensing) RH 85 % ELECTRO-OPTICAL CHARACTERISTICS (TC = 25°C, unless otherwise specified) Parameter <R> Symbol Operating Voltage Vop Threshold Current Ith Differential Efficiency ηd Center Wavelength λC Conditions MIN. Po = 13.0 mW 0.40 Po = 13.0 mW, RMS (−20 dB) TYP. MAX. Unit 1.1 1.5 V 6 15 mA 0.50 1 276 W/A 1 352 nm 1.5 2.8 nm TC = −40 to +85°C Spectral Width σ Po = 13.0 mW, RMS (−20 dB) TC = −40 to +85°C Rise Time tr 10-90% 0.15 0.3 ns Fall Time tf 90-10% 0.15 0.3 ns Monitor Current Im VR = 1.5 V, Po = 13.0 mW Monitor Dark Current ID VR = 10 V Monitor PD Terminal Capacitance Ct VR = 10 V, f = 1 MHz Fiber Coupling Power Pf Focal Distance 4 Df 100 5 Po = 13.0 mW, Optimized Coupling with 8 degree angled SMF Data Sheet PL10531EJ03V0DS µA 200 100 nA 20 pF 2.0 5.85 6.35 mW 6.85 mm NX5315EH TYPICAL CHARACTERISTICS (TC = −40 to +85°C, unless otherwise specified) OPTICAL OUTPUT POWER vs. FORWARD CURRENT OPERATING CURRENT AND THRESHOLD CURRENT vs. CASE TEMPERATURE 100 10 TC = –40˚C Operating Current Iop (mA), Threshold Current Ith (mA) Optical Output Power Po (mW) 12 +85˚C +25˚C 8 6 4 2 0 10 20 30 40 50 60 50 Iop Ith 10 5 1 –60 –40 –20 0 20 40 60 80 100 Case Temperature TC (˚C) Forward Current IF (mA) TEMPERATURE DEPENDENCE OF CENTER WAVELENGTH 1 350 Center Wavelength λC (nm) <R> 1 340 1 330 1 320 1 310 1 300 1 290 1 280 1 270 –60 –40 –20 0 20 40 60 80 100 Case Temperature TC (˚C) Remark The graphs indicate nominal characteristics. Data Sheet PL10531EJ03V0DS 5 NX5315EH TYPICAL CHARACTERISTICS (TC = 25°C, unless otherwise specified) FORWARD CURRENT vs. FORWARD VOLTAGE OPTICAL OUTPUT POWER vs. MONITOR CURRENT Optical Output Power Po (mW) 15 40 30 20 10 0 1 2 5 200 300 400 Monitor Current Im (µA) SPECTRUM TOLERANCE OF FIBER COUPLING DISTANCE (Z) –20 –30 –40 –50 –60 –70 –80 1 310 1 320 1 330 3.0 500 Z Pf 2.5 SMF Po = 13 mW 2.0 1.5 1.0 0.5 5.6 Wavelength λ (nm) 5.8 6.0 6.2 6.4 Z-Axis Tolerance Z (mm) Remark The graphs indicate nominal characteristics. 6 100 Forward Voltage VF (V) –10 –90 1 300 10 0 3 Optical Output Power from Fiber Pf (mW) Forward Current IF (mA) 50 Relative Intensity <R> Data Sheet PL10531EJ03V0DS 6.6 6.8 4590 Patrick Henry Drive Santa Clara, CA 95054-1817 Telephone: (408) 919-2500 Facsimile: (408) 988-0279 Subject: Compliance with EU Directives CEL certifies, to its knowledge, that semiconductor and laser products detailed below are compliant with the requirements of European Union (EU) Directive 2002/95/EC Restriction on Use of Hazardous Substances in electrical and electronic equipment (RoHS) and the requirements of EU Directive 2003/11/EC Restriction on Penta and Octa BDE. CEL Pb-free products have the same base part number with a suffix added. The suffix –A indicates that the device is Pb-free. The –AZ suffix is used to designate devices containing Pb which are exempted from the requirement of RoHS directive (*). In all cases the devices have Pb-free terminals. All devices with these suffixes meet the requirements of the RoHS directive. This status is based on CEL’s understanding of the EU Directives and knowledge of the materials that go into its products as of the date of disclosure of this information. Restricted Substance per RoHS Concentration Limit per RoHS (values are not yet fixed) Concentration contained in CEL devices -A Not Detected Lead (Pb) < 1000 PPM Mercury < 1000 PPM Not Detected Cadmium < 100 PPM Not Detected Hexavalent Chromium < 1000 PPM Not Detected PBB < 1000 PPM Not Detected PBDE < 1000 PPM Not Detected -AZ (*) If you should have any additional questions regarding our devices and compliance to environmental standards, please do not hesitate to contact your local representative. Important Information and Disclaimer: Information provided by CEL on its website or in other communications concerting the substance content of its products represents knowledge and belief as of the date that it is provided. CEL bases its knowledge and belief on information provided by third parties and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. CEL has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. CEL and CEL suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall CEL’s liability arising out of such information exceed the total purchase price of the CEL part(s) at issue sold by CEL to customer on an annual basis. See CEL Terms and Conditions for additional clarification of warranties and liability.