CML OA-6012

Type
Cold Cathode Lamp Inverter Drive module
12VDC input
Connector system
JST XHP-2
Part No.
INV 8 (OA-6012-0505D)
CCFL output
Connector system
JST XHP-3
- +
TR1
L1
C1
R1
T1
R2
C3
C4
TR2
L75 x W25 x H15
Drawing not to scale
All dimensions in mm
CHARACTERISTIC DATA
Dual Output suitable for CCFL length:
Input Voltage
Input Current
No Load Output Voltage
Lamp Output Voltage (VL)
Nominal Drive current (IL)
300 ~ 420 mm
12VDC ± 1.5V
900 mA maximum
1200V rms minimum, 1400V rms nominal
1000V rms nominal
12 mA ± 1mA (6mA per output)
Operating frequency (f)
Operating temperature
Operating humidity
Operating life
28 ± 5 kHz
0 ~ 50 ºC
5 ~ 70% RH
20,000 hours @ 13.2VDC
NOTES:
1. The inverter module should be protected from moisture, condensation and freezing.
2. Suitable screening may be necessary for electromagnetic compatibility and protection.
3. The use of silicone rubber stranded wire is recommended for connecting the CFFL.
4. Danger of electric shock.