Part No: CC-0601 Date: 8/21/2006 Description: magnetic buzzer Page No: 1 of 4 Unit: mm Specifications Rated voltage 1.5 Vo-p Operating voltage Mean current 1.0 - 1.7 Vo-p 80 mA max. Coil resistance Coil impedance Sound output 6 ±1 Ω 8Ω Min. 70 (Typical 77) dBA Rated frequency Operating tempurature Storage tempurature Dimensions Weight Material Terminal RoHS 3,000 Hz -20 ~ +60° C -30 ~ +70° C ø6.6 x H3.5 mm 0.4 g PPO (Black) Pin type (Au Plating) yes Applying rated voltage, 3000 Hz square wave, ½ duty Distance at 10cm (A-weight free air). Applying rated voltage of 3000 Hz, square wave, ½ duty. See attached drawing See attached drawing Frequency Response Curve Phone: 800.275.4899 Fax: 503.612.2381 www.cui.com 20050 SW 112th Ave. Tualatin, OR 97062 Part No: CC-0601 Date: 8/21/2006 Description: magnetic buzzer Page No: 2 of 4 Unit: mm Appearance Drawing Tolerance: ±0.5 Measurement Method Phone: 800.275.4899 Fax: 503.612.2381 www.cui.com 20050 SW 112th Ave. Tualatin, OR 97062 Part No: CC-0601 Date: 8/21/2006 Description: magnetic buzzer Page No: 3 of 4 Unit: mm Mechanical Characteristics Item Solderability Soldering Heat Resistance Terminal Mechanical Strength Vibration Drop Test Test Condition Lead terminals are immersed in rosin for 5 seconds and then immersed in a solder bath of +270 ±5°C for 3 ±1 seconds. Lead terminals are immersed in solder bath of +260 ±5°C for 3 ±1 seconds. The force of 9.8 N (1.0 kg) should be applied to the terminals. The buzzer will be measured after applying a vibration amplitude of 1.5 mm with 10 to 55 Hz band of vibration frequency to each of the 3 perpendicular directions for 2 hours (6 hours total). The part is to be dropped from a height of 75 cm onto a 40 mm thick wooden board 3 times in 3 axis (X, Y, Z) for a total of 9 drops. Evaluation Standard 90% min. of lead terminals should be covered with fresh solder. (Except the edge of the terminal.) No in interference in operation. Test Condition The part will be subjected to +70°C for 96 hours. The part will be subjected to -30°C for 96 hours The part will be subjected to 10 cycles. One cycle will consist of: Evaluation Standard No damage or cutting off. After the test, the part should meet specifications without any damage to the appearance and the SPL should be within ±10 dBA of the initial measurement. Environment Test Item High temp. test Low temp. test Thermal shock Temp./Humidity cycle Phone: 800.275.4899 The part shall be subjected to 10 cycles. One cycle will be 24 hours and consist of: Fax: 503.612.2381 www.cui.com After the test, the part should meet specifications without any damage to the appearance or performance except SPL. After 4 hours at 25°C, the SPL should be within ±10 dBA of the initial measurement. 20050 SW 112th Ave. Tualatin, OR 97062 Part No: CC-0601 Date: 8/21/2006 Description: magnetic buzzer Page No: 4 of 4 Unit: mm Reliability Tests Item Operating (Life Test) Test Condition 1. Continuous life test: The part will be subjected to 72 hours at 45°C with 1.5 V, 3000 Hz applied. 2. Intermittent life test: A duty cycle of 1 minute on, 1 minute off, a minimum of 10,000 times at room temp. (+25 ±10°C) with 1.5 V, 3000 Hz applied. Evaluation Standard After the test, the part should meet specifications without any damage to the appearance or performance except SPL. After 4 hours at 25°C, the SPL should be within ±10 dBA of the initial measurement. Test Conditions Standard Test Condition Judgement Test Condition a) Tempurature: +5 ~ +35°C a) Tempurature: +25±2°C b) Humidity: 45 - 85% b) Humidity: 60 - 70% c) Pressure: 860 - 1060 mbar c) Pressure: 860 - 1060 mbar Packaging Each minimum package of products will be in a carton box and it should be clearly marked with the Part Number, Quantity, and Outgoing Inspection Number. There should be no mechanical damage to the products during transportation and/or in storage. Phone: 800.275.4899 Fax: 503.612.2381 www.cui.com 20050 SW 112th Ave. Tualatin, OR 97062