CUI CMT-1603

Date: 9/19/2006
Part No: CMT-1603
Unit: mm
Description: piezo audio transducer
Page No: 1 of 6
Specifications
Operating voltage
Current consumption
Sound pressure level
Electrostatic capacity
Operating tempurature
Storage tempurature
Dimensions
Weight
Material
Terminal
RoHS
25 Vp-p max.
3 mA max.
at 3 Vp-p, square wave, 4.0 KHz
70 db min.
at 10 cm / 3 Vp-p, square wave, 4.0 KHz
14,000 pF ±30%
at 1 KHz / 1 V
-30 ~ +70° C
-40 ~ +85° C
L16.0 x W16.0 x H2.6 mm
0.96 g max.
LCB (White) + PCB (FR4)
Pin type (Sn Plating)
yes
Appearance Drawing
Tolerance: ±0.2
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 9/19/2006
Part No: CMT-1603
Unit: mm
Description: piezo audio transducer
Page No: 2 of 6
Typical Frequency Response Curve
Measurement Method
S.P.L. Measuring Circuit
Input Signal: 3 V p-p, 4.0 KHz, Square Wave
Mic: RION UC 30
S.G.: Hewlett Packard 33120A Function Generator or equivalent
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 9/19/2006
Part No: CMT-1603
Unit: mm
Description: piezo audio transducer
Page No: 3 of 6
Mechanical Characteristics
Item
Solderability
Soldering Heat Resistance
Terminal Mechanical Strength
Vibration
Phone: 800.275.4899
Evaluation Standard
Test Condition
95% of the surface of the lead
Lead terminals are immersed in rosin for
pads should be covered with
5 seconds and then immersed in solder bath
solder.
of 270 ±5°C for 2 ±0.5 seconds.
1) IR Reflow
Pre-heating conditions should be 150~200°C for
60 to 180 seconds. Ascending time up to
245°C should be longer than 55 seconds.
Heating conditions should be within 20 to 40
seconds at 245°C min. Peak temperature
should be lower than 255°C. The transducer
should be measured after 1 hour in normal
No interference in operation.
conditions.
2) Soldering Iron
A soldering iron of 270±5°C should be placed
0.5mm away from the electrode of the
transducer. Melted solder should be applied to
the electrode for 3±1 seconds. The transducer
should be measured after 4 hours in normal
conditions.
For 10 seconds, the force of 9.8N (1.0kg) is
applied to each terminal in axial direction.
The transducer should be subjected to a
vibration cycle of 10 to 55 Hz band of vibration
frequency for a period of 1 minute. Total peak
amplitude should be 1.5mm. The vibration test
should consist of 2 hours per axis in each axial
direction (X, Y, Z) for a total of 6 hours.
Fax: 503.612.2381
www.cui.com
No damage or cutting off.
After the test, the part should
meet specifications without any
damage in appearance or
performance except for SPL. The
SPL should be within ±10dB
compared with the initial
measurement.
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 9/19/2006
Part No: CMT-1603
Unit: mm
Description: piezo audio transducer
Page No: 4 of 6
Environment Test
Item
High temp. test
Low temp. test
Humidity test
Temp. cycle test
Test Condition
After being placed in a chamber at +85°C for
240 hours.
After being placed in a chamber at -40°C for
240 hours.
After being placed in a chamber at +40°C and
90±5% relative humidity for 240 hours.
The part shall be subjected to 5 cycles. One
cycle will consist of:
Evaluation Standard
Test Condition
1. Continuous life test:
The part will be subjected to 48 hours of
continuous operation at +55°C with rated
voltage applied.
Evaluation Standard
The transducer will be measured
after being placed at +25°C for 4
hours. The value of the
oscillation frequency/current
consumption should be ±10%
compared to the initial
measurements. The SPL should
be within ±10dB compared to
the initial measurements.
The transducer should be
measured after being placed at
+25°C for 4 hours. The value of
the oscillation frequency/current
consumption should be ±10%
compared to the initial
measurements. The SPL should
be within ±10dB compared to the
initial measurements.
Reliability Test
Item
Operating (Life Test)
2. Intermittent life test:
A duty cycle of 1 minute on, 1 minute off, a
minimum of 5,000 times at room temp
(+25 ±2°C) with rated voltage applied.
Test Conditions
Standard Test Condition
Judgement Test Condition
Phone: 800.275.4899
a) Tempurature: +5 ~ +35°C
a) Tempurature: +25 ±2°C
Fax: 503.612.2381
b) Humidity: 45 - 85%
b) Humidity: 60 - 70%
www.cui.com
c) Pressure: 860-1060 mbar
c) Pressure: 860-1060 mbar
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 9/19/2006
Part No: CMT-1603
Unit: mm
Description: piezo audio transducer
Page No: 5 of 6
Recommended Temperature Profile for Reflow Oven
Note: 255°C is less than 20 seconds, but only pass the lead
free reflow once
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 9/19/2006
Part No: CMT-1603
Unit: mm
Description: piezo audio transducer
Page No: 6 of 6
Packaging
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062