CUI VABD6-D12-D12

rev.
page
1 of 3
date
08/2007
DESCRIPTION: DC/DC converter
PART NUMBER: VABD6 series
features
·5-6 W isolated output
·efficiency to 82%
·2:1 input range
·regulated outputs
·Pi input filter
·24-Pin DIP package
·meets EN55022 Class B, conducted
·remote ON/OFF option
model
number
VABD6-D12-S3R3
VABD6-D12-S5
VABD6-D12-S12
VABD6-D12-S15
VABD6-D12-D12
VABD6-D12-D15
VABD6-D12-D5
VABD6-D24-S3R3
VABD6-D24-S5
VABD6-D24-S12
VABD6-D24-S15
VABD6-D24-D12
VABD6-D24-D15
VABD6-D24-D5
VABD6-D48-S3R3
VABD6-D48-S5
VABD6-D48-S12
VABD6-D48-S15
VABD6-D48-D12
VABD6-D48-D15
VABD6-D48-D5
input
voltage
9-18VDC
9-18VDC
9-18VDC
9-18VDC
9-18VDC
9-18VDC
9-18VDC
18-36VDC
18-36VDC
18-36VDC
18-36VDC
18-36VDC
18-36VDC
18-36VDC
36-72VDC
36-72VDC
36-72VDC
36-72VDC
36-72VDC
36-72VDC
36-72VDC
output
voltage
3.3VDC
5VDC
12VDC
15VDC
±12VDC
±15VDC
±5VDC
3.3VDC
5VDC
12VDC
15VDC
±12VDC
±15VDC
±5VDC
3.3VDC
5VDC
12VDC
15VDC
±12VDC
±15VDC
±5VDC
output
current
1000mA
1000mA
470mA
400mA
±230mA
±190mA
±500mA
1000mA
1000mA
470mA
400mA
±230mA
±190mA
±500mA
1000mA
1000mA
470mA
400mA
±230mA
±190mA
±500mA
input current
no load
full load
7.5mA
393mA
7.5mA
545mA
7.5mA
585mA
7.5mA
625mA
12mA
575mA
12mA
590mA
12mA
545mA
5mA
197mA
5mA
265mA
5mA
285mA
5mA
305mA
7.5mA
285mA
7.5mA
295mA
7.5mA
265mA
2mA
98mA
2mA
133mA
2mA
145mA
2mA
154mA
3mA
142mA
3mA
147mA
3mA
133mA
NOTES:
1.
2.
3.
4.
suffix
suffix
suffix
suffix
“HM” for 1.5K Vdc isolation
“H” for 3K Vdc isolation
“-SMT” for SMT case style
“-1” for on/off control option
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
efficiency
70%
76%
80%
80%
80%
80%
76%
70%
78%
82%
82%
81%
81%
78%
70%
78%
81%
81%
81%
81%
78%
rev.
DESCRIPTION: DC/DC converter
PART NUMBER: VABD6 series
INPUT
input voltage range
12V
24V
9-18V
18-36
48V
36-72
Pi type
input filter
OUTPUT
voltage accuracy
voltage balance (dual)
temperature coefficient
ripple and noise, 20MHz BW
3.3V / 5V
12V / 15V
short circuit protection
line regulation
single/dual 1
load regulation
single 2
dual³
±2.0% max.
±1.0% max.
±0.05% / °C max.
100mV p-p max.
1% p-p max.
continuous
±0.5%
±0.5%
±1.0%
GENERAL SPECIFICATIONS
efficiency
isolation resistance
see table
10 9 Ohms
switching frequency
100kHz min.
isolation resistance
10 9 Ohms
operating temperature range
-25°C to +71°C
storage temperature
-40°C to +100°C
cooling
free air convection
EMI/RFI
conductive EMI meet EN55022
dimensions
1.25x0.8x0.5 inches
class B
(31.8x20.3x12.7mm)
ISOLATION VOLTAGE
500 VDC min
1.5K VDC min
3K VDC min4
standard models
suffix “HM” models
suffix “H” models
CASE MATERIAL
standard models
non-conductive black plastic
suffix “M” models5
black coated copper with
non-conductive base
NOTES:
1. measured from high line to low line
2. measured from full load to 10% load
3. measured from full load to 1/4 load
4. non-conductive black plastic only
5. suffix “-1” to the model number with
remote on/off for “H”/”HM” versions only
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
page
2 of 3
date
08/2007
rev.
DESCRIPTION: DC/DC converter
PART NUMBER: VABD6 series
DIMENSIONS (mm)
DERATING CURVE
120%
71
-25
100%
Output Load(%)
80%
60%
Plastic Case
Copper Case
40%
20%
95
0%
-25
0
25
50
75
100
100
Ambient Temperature(˚C)
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
page
3 of 3
date
08/2007