NVM - 4x NIGHT VISION MULTIPLIERS ELECTRICAL CHARACT ERISTIC (at TAir = 25OC Unless Otherwise Specified) NVM - 4x 8 # of Stages Multiplication Factor 4*Vpp Peak To Peak Input Voltage, Vpp 500V 2,000 V dc Peak output voltage 25 - 50 khz Typical Frequency Range Max. Forward Voltage Drop DC- to DC+ @ 1 mA 32 V 600 V ac Max AC Input O O O O Operating Temperature, To -55 C to +85 C Storage Temperature, Ts t -55 C to +85 C NOTES: It is recommended that a device be encapsulated in a thermally conductive insulator to prevent damage from excess heat and electrical arcing. Metallic Capacitor Surface EDI reserves the rightto change these specifications at any time without notice. ELECTRONIC DEVICES, INC. DESIGNERS AND MANUFACTURERS OF SOLID STATE DEVICES SINCE 1951. 21 GRAY OAKS AVENUE * YONKERS. NEW YORK 10710 914-965-4400 Ee-mail:[email protected] *Wwebsite:http:// www.edidiodes.com * FAX 914-965-5531 * 1-800-678-0828