EPCOS B39182-B4221-U810

SAW Components
Data Sheet B4221
SAW Components
B4221
Low-Loss Dual Band Filter for Mobile Communication
942,5 / 1842,5 MHz
Preliminary Data
Ceramic package QCC8D
Features
■ Low-loss RF filter for mobile telephone EGSM
and PCN system , receive path
■ Usable passband:
Filter 1 (EGSM): 35 MHz
Filter 2 (PCN):
75 MHz
■ Suitable for GPRS class 1 to 12
■ Ceramic package for Surface
Technology (SMT)
Mounted
Terminals
■ Ni, gold-plated
Dimensions in mm, approx. weight 0,037 g
Pin configuration
1
3
5
7
Input [ Filter 1]
Input [ Filter 2 ]
Output [ Filter 2 ]
Output [ Filter 1 ]
2, 6
4, 8
to be grounded
Case ground
Type
Ordering code
B4221
B39182-B4221-U810
Marking and Package
according to
C61157-A7-A72
Electrostatic Sensitive Device (ESD)
Maximum ratings
Operable temperature range
Storage temperature range
DC voltage
Input power max.
T
Tstg
VDC
PIN
– 20 / + 70
– 40 / + 85
3
˚C
˚C
V
EGSM:
15
dBm
PCN:
12
dBm
2
May 16, 2002
Packing
according to
F61074-V8101-Z000
SAW Components
B4221
942,5 / 1842,5 MHz
Low-Loss Dual Band Filter for Mobile Communication
Preliminary Data
Characteristics Filter 1 ( EGSM )
T = 25 ± 2˚C
ZS = 50 Ω
ZL = 50 Ω
Operating temperature range:
Terminating source impedance:
Terminating load impedance:
fc
Center frequency
min.
typ.
max.
—
942,50
—
—
3,2
3,5
dB
dB
MHz
αmax
Maximum insertion attenuation
925,0 ... 960,0
MHz
∆α
Amplitude ripple (p-p)
925,0 ... 960,0
MHz
—
1,4
1,9
925,0 ... 960,0
MHz
—
1,7
2,1
925,0 ... 960,0
MHz
—
1,7
2,1
Input VSWR
Output VSWR
αmin
Attenuation
0,0
700,0
880,0
905,0
980,0
982,0
1005,0
1035,0
1300,0
1360,0
2500,0
3120,0
3700,0
... 700,0
... 880,0
... 905,0
... 915,0
... 982,0
...1005,0
...1035,0
...1300,0
...1360,0
...2500,0
...3120,0
...3700,0
...6000,0
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
40
35
31
15
20
25
35
33
32
28
15
8
6
45
39
36
20
27
29
43
37
35
32
22
11
8
—
—
—
—
—
—
—
—
—
—
—
—
—
-130
-120
-110
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Input reflection coefficient @ 1842,5 Mhz
Phase
3
May 16, 2002
˚
SAW Components
B4221
942,5 / 1842,5 MHz
Low-Loss Dual Band Filter for Mobile Communication
Preliminary Data
Characteristics Filter 1 ( EGSM )
T = -20 to +70˚C
ZS = 50 Ω
ZL = 50 Ω
Operating temperature range:
Terminating source impedance:
Terminating load impedance:
fc
Center frequency
Maximum insertion attenuation
925,0 ... 960,0
min.
typ.
max.
—
942,50
—
—
3,4
3,9
dB
dB
MHz
αmax
MHz
∆α
Amplitude ripple (p-p)
925,0 ... 960,0
MHz
—
1,6
2,0
925,0 ... 960,0
MHz
—
1,8
2,2
925,0 ... 960,0
MHz
—
1,8
2,2
Input VSWR
Output VSWR
αmin
Attenuation
0,0
700,0
880,0
905,0
980,0
982,0
1005,0
1035,0
1300,0
1360,0
2500,0
3120,0
3700,0
... 700,0
... 880,0
... 905,0
... 915,0
... 982,0
...1005,0
...1035,0
...1300,0
...1360,0
...2500,0
...3120,0
...3700,0
...6000,0
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
40
35
31
15
20
25
35
33
32
28
15
8
6
45
39
36
20
27
29
43
37
35
32
22
11
8
—
—
—
—
—
—
—
—
—
—
—
—
—
-130
-120
-110
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Input reflection coefficient @ 1842,5 MHz
Phase
4
May 16, 2002
˚
SAW Components
B4221
942,5 / 1842,5 MHz
Low-Loss Dual Band Filter for Mobile Communication
Preliminary Data
Characteristics Filter 2 ( PCN )
T = 25 ± 2˚C
ZS = 50 Ω
ZL = 50 Ω
Operating temperature range:
Terminating source impedance:
Terminating load impedance:
min.
typ.
max.
—
1842,5
—
—
—
—
3,0
2,5
3,0
3,5
3,3
3,5
dB
dB
dB
MHz
—
1,5
1,9
dB
1805,0 ...1880,0
MHz
—
1,8
2,1
1805,0 ...1880,0
MHz
—
1,8
2,1
0,0
1480,0
1710,0
1765,0
1907,0
1914,0
1980,0
3000,0
3400,0
4000,0
5000,0
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
fc
Center frequency
Maximum insertion attenuation
1805,0 ...1815,0
1815,0 ...1870,0
1870,0 ...1880,0
Amplitude ripple (p-p)
1805,0 ...1880,0
MHz
αmax
MHz
MHz
MHz
∆α
Input VSWR
Output VSWR
αmin
Attenuation
...1480,0
...1710,0
...1765,0
...1785,0
...1914,0
...1980,0
...3000,0
...3400,0
...4000,0
...5000,0
...6000,0
37
25
16
11
11
16
22
20
18
12
8
40
35
24
19
22
23
26
29
24
19
12
—
—
—
—
—
—
—
—
—
—
—
-150
-140
-130
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Input reflection coefficient @ 947,5 MHz
Phase
5
May 16, 2002
˚
SAW Components
B4221
942,5 / 1842,5 MHz
Low-Loss Dual Band Filter for Mobile Communication
Preliminary Data
Characteristics Filter 2 ( PCN )
T = -20 to +70˚C
ZS = 50 Ω
ZL = 50 Ω
Operating temperature range:
Terminating source impedance:
Terminating load impedance:
min.
typ.
max.
—
1842,5
—
—
—
—
3,3
2,6
3,3
3,9
3,3
3,9
dB
dB
dB
MHz
—
1,6
2,0
dB
1805,0 ...1880,0
MHz
—
1,9
2,2
1805,0 ...1880,0
MHz
—
1,9
2,2
0,0
1480,0
1710,0
1765,0
1907,0
1914,0
1980,0
3000,0
3400,0
4000,0
5000,0
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
fc
Center frequency
Maximum insertion attenuation
1805,0 ...1815,0
1815,0 ...1870,0
1870,0 ...1880,0
Amplitude ripple (p-p)
1805,0 ...1880,0
MHz
αmax
MHz
MHz
MHz
∆α
Input VSWR
Output VSWR
αmin
Attenuation
...1480,0
...1710,0
...1765,0
...1785,0
...1914,0
...1980,0
...3000,0
...3400,0
...4000,0
...5000,0
...6000,0
37
25
15
10
10
15
22
20
18
12
8
40
35
24
19
22
23
26
29
24
19
12
—
—
—
—
—
—
—
—
—
—
—
-150
-140
-130
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Input reflection coefficient @ 947,5 MHz
Phase
6
May 16, 2002
˚
SAW Components
B4221
Low-Loss Dual Band Filter for Mobile Communication
Preliminary Data
Transfer function Filter 1 ( EGSM )- spec at 25 ˚C
Transfer function Filter 1 ( EGSM ) - wideband
7
May 16, 2002
942,5 / 1842,5 MHz
SAW Components
B4221
Low-Loss Dual Band Filter for Mobile Communication
Preliminary Data
Transfer function Filter 2 ( PCN ) - spec at 25 ˚C
Transfer function Filter 2 ( PCN ) - wideband
8
May 16, 2002
942,5 / 1842,5 MHz
SAW Components
B4221
Low-Loss Dual Band Filter for Mobile Communication
942,5 / 1842,5 MHz
Preliminary Data
Published by EPCOS AG
Surface Acoustic Wave Components Division, SAW MC WT
P.O. Box 80 17 09, D-81617 München
 EPCOS AG 2002. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for
the Supply of Products and Services of the Electrical and Electronics Industry recommended by the
ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
9
May 16, 2002