EXAR XR16M2751IM48

XR16M2751
PRELIMINARY
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE
JUNE 2007
P1.0.0
GENERAL DESCRIPTION
The XR16M27511 (M2751) is a high performance
dual universal asynchronous receiver and transmitter
(UART) with 64 byte TX and RX FIFOs. The device
operates from 1.62 to 3.6 volts and is pin-to-pin and
software compatible to Exar’s XR16V2751. The
device includes 2 additional capabilities over the
XR16M2750: Intel and Motorola data bus selection
and a “PowerSave” mode to further reduce sleep
current to a minimum during sleep mode. It supports
the Exar’s enhanced features of programmable FIFO
trigger level and FIFO level counters, automatic
hardware (RTS/CTS) and software flow control,
automatic RS-485 half duplex direction control output
and a complete modem interface. An internal
loopback capability allows system diagnostics.
Independent programmable fractional baud rate
generators are provided in each channel to select
data rates up to 8 Mbps at 3.3 Volt and 8X sampling
clock. The M2751 is available in a 48-pin TQFP
package.
FEATURES
• 1.62 to 3.6 Volt Operation
• Pin-to-pin compatible to Exar’s XR16V2751 in the
48-TQFP package
• Two independent UART channels
■
■
■
■
■
■
■
■
■
■
■
NOTE: 1 Covered by U.S. Patent #5,649,122 and #5,949,787
■
APPLICATIONS
■
• Portable Appliances
• Telecommunication Network Routers
• Ethernet Network Routers
• Cellular Data Devices
• Factory Automation and Process Controls
Register set identical to 16V2751
Data rate of up to 8 Mbps at 3.3 V, and 6.25
Mbps at 2.5 V and 4 Mbps at 1.8 V with 8X
sampling rate
Fractional Baud Rate Generator
Transmit and Receive FIFOs of 64 bytes
Programmable TX and RX FIFO Trigger Levels
Transmit and Receive FIFO Level Counters
Automatic Hardware (RTS/CTS) Flow Control
Selectable Auto RTS Flow Control Hysteresis
Automatic Software (Xon/Xoff) Flow Control
Automatic RS-485 Half-duplex Direction
Control Output via RTS#
Wireless Infrared (IrDA 1.0) Encoder/Decoder
Automatic sleep mode with wake-up interrupt
Full modem interface
• PowerSave Feature reduces sleep current to 15
µA
• Device Identification and Revision
• Crystal oscillator (up to 32MHz) or external clock
(up to 64MHz) input
• 48-TQFP package
FIGURE 1. XR16M2751 BLOCK DIAGRAM
1.62 to 3.6V VCC
PwrSave
GND
A2:A0
D7:D0
UART Channel A
IOR# (VCC)
IOW# (R/W#)
CSA# (CS#)
UART
Regs
CSB# (A3)
BRG
INTA (IRQ#)
INTB (logic 0)
TXRDYA#
TXRDYB#
RXRDYA#
RXRDYB#
Reset (Reset#)
16/68#
CLKSEL
HDCNTL#
Intel or
Motorola
Data Bus
Interface
64 Byte TX FIFO
TX & RX
IR
ENDEC
TXA, RXA, DTRA#,
DSRA#, RTSA#,
DTSA#, CDA#, RIA#,
OP2A#
64 Byte RX FIFO
UART Channel B
(same as Channel A)
Crystal Osc/Buffer
TXB, RXB, DTRB#,
DSRB#, RTSB#,
CTSB#, CDB#, RIB#,
OP2B#
XTAL1
XTAL2
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • (510) 668-7000 • FAX (510) 668-7017 • www.exar.com
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
37 HDCNTL#
DSRA#
38 CTSA#
40 CDA#
39
41 RIA#
42 VCC
43 TXRDYA#
45 D1
44 D0
46 D2
48 D4
47 D3
FIGURE 2. PIN OUT ASSIGNMENT
D5
1
36 RESET
D6
2
35 DTRB#
D7
3
34 DTRA#
RXB
4
33 RTSA#
RXA
5
TXRDYB#
6
TXA
7
TXB
8
29 INTB
OP2B#
9
28 A0
CSA#
10
27 A1
CSB#
11
26 A2
PWRSAVE
12
25 CLKSEL
32 OP2A#
31 RXRDYA#
37 HDCNTL#
DSRA#
38 CTSA#
40 CDA#
39
41 RIA#
42 VCC
43 TXRDYA#
45 D1
44 D0
46 D2
48 D4
D5
1
36 RESET#
D6
2
35 DTRB#
D7
3
34 DTRA#
RXB
4
33 RTSA#
RXA
5
TXRDYB#
6
TXA
7
TXB
8
29 NC
OP2B#
9
28 A0
CS#
10
27 A1
A3
11
26 A2
PWRSAVE
12
25 CLKSEL
32 OP2A#
31 RXRDYA#
30 IRQ#
16/68# 24
CTSB# 23
RTSB# 22
RIB# 21
20
DSRB#
NC 19
RXRDYB# 18
GND 17
R/W# 15
CDB# 16
XTAL1 13
XR16M2751
48-pin TQFP
in 68 (Motorola) Mode
XTAL2 14
16/68# 24
VCC
47 D3
30 INTA
CTSB# 23
RTSB# 22
RIB# 21
20
DSRB#
IOR# 19
RXRDYB# 18
GND 17
IOW# 15
CDB# 16
XTAL2 14
XTAL1 13
XR16M2751
48-pin TQFP
in 16 (Intel) Mode
GND
ORDERING INFORMATION
PART NUMBER
PACKAGE
OPERATING TEMPERATURE RANGE
DEVICE STATUS
XR16M2751IM48
48-Lead TQFP
-40°C to +85°C
Active
2
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
PIN DESCRIPTIONS
Pin Description
NAME
48-TQFP
PIN #
TYPE
DESCRIPTION
Address data lines [2:0]. These 3 address lines select one of the internal registers in
UART channel A/B during a data bus transaction.
DATA BUS INTERFACE
A2
A1
A0
26
27
28
I
D7
D6
D5
D4
D3
D2
D1
D0
3
2
1
48
47
46
45
44
I/O
IOR#
(VCC)
19
I
When 16/68# pin is HIGH, the Intel bus interface is selected and this input becomes
read strobe (active low). The falling edge instigates an internal read cycle and
retrieves the data byte from an internal register pointed by the address lines [A2:A0],
puts the data byte on the data bus to allow the host processor to read it on the rising
edge.
When 16/68# pin is LOW, the Motorola bus interface is selected and this input is not
used and should be connected to VCC.
IOW#
(R/W#)
15
I
When 16/68# pin is HIGH, it selects Intel bus interface and this input becomes write
strobe (active low). The falling edge instigates the internal write cycle and the rising
edge transfers the data byte on the data bus to an internal register pointed by the
address lines.
When 16/68# pin is LOW, the Motorola bus interface is selected and this input
becomes read (HIGH) and write (LOW) signal.
CSA#
(CS#)
10
I
When 16/68# pin is HIGH, this input is chip select A (active low) to enable channel A
in the device.
When 16/68# pin is LOW, this input becomes the chip select (active low) for the
Motorola bus interface.
CSB#
(A3)
11
I
When 16/68# pin is HIGH, this input is chip select B (active low) to enable channel B
in the device.
When 16/68# pin is LOW, this input becomes address line A3 which is used for channel selection in the Motorola bus interface. Input logic 0 selects channel A and logic 1
selects channel B.
INTA
(IRQ#)
30
O
When 16/68# pin is HIGH for Intel bus interface, this output becomes channel A interrupt output. The output state is defined by the user through the software setting of
MCR[3]. INTA is set to the active mode and OP2A# output to a logic 0 when MCR[3]
is set to a logic 1. INTA is set to the three state mode and OP2A# to a logic 1 when
MCR[3] is set to a logic 0. See MCR[3].
When 16/68# pin is LOW for Motorola bus interface, this output becomes device
interrupt output (active low, open drain). An external pull-up resistor is required for
proper operation.
Data bus lines [7:0] (bidirectional).
3
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
Pin Description
NAME
48-TQFP
PIN #
TYPE
DESCRIPTION
INTB
29
O
UART channel B Interrupt output. The output state is defined by the user through the
software setting of MCR[3]. INTB is set to the active mode and OP2B# output LOW
when MCR[3] is set to a logic 1. INTB is set to the three state mode and OP2B# output HIGH when MCR[3] is set to a logic 0 (default). See MCR[3].
TXRDYA#
43
O
UART channel A Transmitter Ready (active low). The output provides the TX FIFO/
THR status for transmit channel A. See Table 3. If it is not used, leave it unconnected.
RXRDYA#
31
O
UART channel A Receiver Ready (active low). This output provides the RX FIFO/
RHR status for receive channel A. See Table 3. If it is not used, leave it unconnected.
TXRDYB#
6
O
UART channel B Transmitter Ready (active low). The output provides the TX FIFO/
THR status for transmit channel B. See Table 4. If it is not used, leave it unconnected.
RXRDYB#
18
O
UART channel B Receiver Ready (active low). This output provides the RX FIFO/
RHR status for receive channel B. See Table 3. If it is not used, leave it unconnected.
MODEM OR SERIAL I/O INTERFACE
TXA
7
O
UART channel A Transmit Data or infrared encoder data. Standard transmit and
receive interface is enabled when MCR[6] = 0. In this mode, the TX signal will be
HIGH during reset or idle (no data). Infrared IrDA transmit and receive interface is
enabled when MCR[6] = 1. In the Infrared mode, the inactive state (no data) for the
Infrared encoder/decoder interface is LOW. If it is not used, leave it unconnected.
RXA
5
I
UART channel A Receive Data or infrared receive data. Normal receive data input
must idle HIGH. The infrared receiver pulses typically idles at LOW but can be
inverted by software control prior going in to the decoder, see MCR[6] and FCTR[2].
If this pin is not used, tie it to VCC or pull it high via a 100k ohm resistor.
RTSA#
33
O
UART channel A Request-to-Send (active low) or general purpose output. This output must be asserted prior to using auto RTS flow control, see EFR[6], MCR[1],
FCTR[1:0], EMSR[5:4] and IER[6]. For auto RS485 half-duplex direction control, see
FCTR[3] and EMSR[3].
CTSA#
38
I
UART channel A Clear-to-Send (active low) or general purpose input. It can be
used for auto CTS flow control, see EFR[7], and IER[7]. This input should be connected to VCC when not used.
DTRA#
34
O
UART channel A Data-Terminal-Ready (active low) or general purpose output. If it is
not used, leave it unconnected.
DSRA#
39
I
UART channel A Data-Set-Ready (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
CDA#
40
I
UART channel A Carrier-Detect (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
RIA#
41
I
UART channel A Ring-Indicator (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
4
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
Pin Description
NAME
48-TQFP
PIN #
TYPE
DESCRIPTION
OP2A#
32
O
Output Port 2 Channel A - The output state is defined by the user and through the
software setting of MCR[3]. INTA is set to the active mode and OP2A# output LOW
when MCR[3] is set to a logic 1. INTA is set to the three state mode and OP2A# output HIGH when MCR[3] is set to a logic 0. See MCR[3]. If INTA is used, this output
should not be used as a general output else it will disturb the INTA output functionality.
TXB
8
O
UART channel B Transmit Data or infrared encoder data. Standard transmit and
receive interface is enabled when MCR[6] = 0. In this mode, the TX signal will be
HIGH during reset or idle (no data). Infrared IrDA transmit and receive interface is
enabled when MCR[6] = 1. In the Infrared mode, the inactive state (no data) for the
Infrared encoder/decoder interface is LOW. If it is not used, leave it unconnected.
RXB
4
I
UART channel B Receive Data or infrared receive data. Normal receive data input
must idle HIGH. The infrared receiver pulses typically idles at logic 0 but can be
inverted by software control prior going in to the decoder, see MCR[6] and FCTR[2].
If this pin is not used, tie it to VCC or pull it high via a 100k ohm resistor.
RTSB#
22
O
UART channel B Request-to-Send (active low) or general purpose output. This port
must be asserted prior to using auto RTS flow control, see EFR[6], MCR[1],
FCTR[1:0], EMSR[5:4] and IER[6]. For auto RS485 half-duplex direction control, see
FCTR[3] and EMSR[3].
CTSB#
23
I
UART channel B Clear-to-Send (active low) or general purpose input. It can be
used for auto CTS flow control, see EFR[7], and IER[7]. This input should be connected to VCC when not used.
DTRB#
35
O
UART channel B Data-Terminal-Ready (active low) or general purpose output. If it is
not used, leave it unconnected.
DSRB#
20
I
UART channel B Data-Set-Ready (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
CDB#
16
I
UART channel B Carrier-Detect (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
RIB#
21
I
UART channel B Ring-Indicator (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
OP2B#
9
O
Output Port 2 Channel B - The output state is defined by the user and through the
software setting of MCR[3]. INTB is set to the active mode and OP2B# output LOW
when MCR[3] is set to a logic 1. INTB is set to the three state mode and OP2B# output HIGH when MCR[3] is set to a logic 0. See MCR[3]. If INTB is used, this output
should not be used as a general output else it will disturb the INTB output functionality.
ANCILLARY SIGNALS
XTAL1
13
I
Crystal or external clock input.
XTAL2
14
O
Crystal or buffered clock output.
PwrSave
12
I
PowerSave (active high). This feature isolates the 2751’s data bus interface from the
host preventing other bus activities that cause higher power drain during sleep mode.
See Sleep Mode with Auto Wake-up and PowerSave Feature section for details.
5
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
Pin Description
NAME
48-TQFP
PIN #
TYPE
DESCRIPTION
16/68#
24
I
Intel or Motorola Bus Select.
When 16/68# pin is HIGH, 16 or Intel Mode, the device will operate in the Intel bus
type of interface.
When 16/68# pin is LOW, 68 or Motorola mode, the device will operate in the Motorola bus type of interface.
CLKSEL
25
I
Baud-Rate-Generator Input Clock Prescaler Select for channel A and B. This input is
only sampled during power up or a reset. Connect to VCC for divide by 1 and GND
for divide by 4. MCR[7] can override the state of this pin following a reset or initialization. See MCR bit-7 and Figure 5 in the Baud Rate Generator section.
HDCNTL#
37
I
Auto RS-485 half-duplex direction output enable for channel A and B (active low).
Connect this pin to VCC for normal RTS# A/B function and to GND for auto RS-485
half-duplex direction output via the RTS# A/B pins. RTS# output goes low for transmit
and high for receive (polarity inversion is available via EMSR[3]). FCTR[3] in channel
A and B have control only if this input is disabled or at VCC.
RESET
(RESET#)
36
I
When 16/68# pin is HIGH for Intel bus interface, this input becomes RESET (active
high). When 16/68# pin is LOW for Motorola bus interface, this input becomes
RESET# (active low).
A 40 ns minimum active pulse on this pin will reset the internal registers and all outputs of channel A and B. The UART transmitter output will be held HIGH, the receiver
input will be ignored and outputs are reset during reset period (see Table 17).
VCC
42
Pwr
1.62V to 3.6V power supply.
GND
17
Pwr
Power supply common, ground.
Pin type: I=Input, O=Output, I/O= Input/output, OD=Output Open Drain.
6
PRELIMINARY
P1.0.0
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
1.0 PRODUCT DESCRIPTION
The XR16M2751 (M2751) integrates the functions of 2 enhanced 16C550 Universal Asynchronous Receiver
and Transmitter (UART). Its features set is compatible to the XR16V2750 and XR16C2850 devices but offers
Intel or Motorola data bus interface and PowerSave to isolate the data bus interface during Sleep mode.
Hence, the M2751 adds 4 more inputs: 16/68#, PwrSave, HDCNTL# and CLKSEL pins. Each UART is
independently controlled having its own set of device configuration registers. The configuration registers set is
16550 UART compatible for control, status and data transfer. Additionally, each UART channel has 64-bytes of
transmit and receive FIFOs, automatic RTS/CTS hardware flow control with hysteresis control, automatic Xon/
Xoff and special character software flow control, programmable transmit and receive FIFO trigger levels, FIFO
level counters, infrared encoder and decoder (IrDA ver 1.0), programmable fractional baud rate generator with
a prescaler of divide by 1 or 4. The XR16M2751 can operate from 1.62V to 3.6V. The M2751 is fabricated with
an advanced CMOS process.
Enhanced Features
The M2751 DUART provides a solution that supports 64 bytes of transmit and receive FIFO memory, instead
of 16 bytes in the ST16C2550 or one byte in the ST16C2450. The M2751 is designed to work with low supply
voltage and high performance data communication systems, that require fast data processing time. Increased
performance is realized in the M2751 by the larger transmit and receive FIFOs, FIFO trigger level control, FIFO
level counters and automatic flow control mechanism. This allows the external processor to handle more
networking tasks within a given time. For example, the ST16C2550 with a 16 byte FIFO, unloads 16 bytes of
receive data in 1.53 ms (This example uses a character length of 11 bits, including start/stop bits at 115.2
Kbps). This means the external CPU will have to service the receive FIFO at 1.53 ms intervals. However with
the 64 byte FIFO in the M2751, the data buffer will not require unloading/loading for 6.1 ms. This increases the
service interval giving the external CPU additional time for other applications and reducing the overall UART
interrupt servicing time. In addition, the programmable FIFO level trigger interrupt and automatic hardware/
software flow control is uniquely provided for maximum data throughput performance especially when
operating in a multi-channel system. The combination of the above greatly reduces the CPU’s bandwidth
requirement, increases performance, and reduces power consumption.
The M2751 supports a half-duplex output direction control signaling pin, RTS# A/B, to enable and disable the
external RS-485 transceiver operation. It automatically switches the logic state of the output pin to the receive
state after the last stop-bit of the last character has been shifted out of the transmitter. After receiving, the logic
state of the output pin switches back to the transmit state when a data byte is loaded in the transmitter. The
auto RS-485 direction control pin is not activated after reset. To activate the direction control function, user has
to set FCTR Bit-3 to “1”. This pin is normally high for receive state, low for transmit state.
Data Bus Interface, Intel or Motorola Type
The 2751 provides a single host interface for the 2 UARTs and supports Intel or Motorola microprocessor
(CPU) data bus interface. The Intel bus compatible interface allows direct interconnect to Intel compatible type
of CPUs using IOR#, IOW# and CSA# or CSB# inputs for data bus operation. The Motorola bus compatible
interface instead uses the R/W#, CS# and A3 signals for data bus transactions. Few data bus interface signals
change their functions depending on user’s selection, see pin description for details. The Intel and Motorola
bus interface selection is made through the pin, 16/68#, pin 24.
Data Rate
The M2751 is capable of operation up to 4 Mbps at 3.3V with 16X internal sampling clock rate and 8 Mbps at
3.3V with 8X sampling clock rate. The device can operate with an external 24 MHz crystal on pins XTAL1 and
XTAL2, or external clock source of up to 64 MHz on XTAL1 pin. With a typical crystal of 14.7456 MHz and
through a software option, the user can set the prescaler bit for data rates of up to 1.84 Mbps.
The rich feature set of the M2751 is available through the internal registers. Automatic hardware/software flow
control, selectable transmit and receive FIFO trigger levels, selectable TX and RX baud rates, infrared
encoder/decoder interface, modem interface controls, and a sleep mode are all standard features.
Following a power on reset or an external reset, the M2751 is software compatible with previous generation of
UARTs, 16C450, 16C550 and 16C650A as well as the 16C850.
7
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
2.0 FUNCTIONAL DESCRIPTIONS
2.1
CPU Interface
The CPU interface is 8 data bits wide with 3 address lines and control signals to execute data bus read and
write transactions. The M2751 data interface supports the Intel compatible types of CPUs and it is compatible
to the industry standard 16C550 UART. No clock (oscillator nor external clock) is required to operate a data
bus transaction. Each bus cycle is asynchronous using CSA/B#, IOR# and IOW# or CS#, R/W# and A3 inputs.
Both UART channels share the same data bus for host operations. A typical data bus interconnection for Intel
and Motorola mode is shown in Figure 3.
FIGURE 3. XR16M2751 TYPICAL INTEL/MOTOROLA DATA BUS INTERCONNECTIONS
VCC
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
A0
A1
A2
A0
A1
DSRA#
CDA#
A2
RIA#
OP2A#
IOR#
IOR#
IOW #
IOW #
UART_CSA#
UART_CSB#
CSA#
CSB#
UART_INTA
INTA
UART_INTB
INTB
TXRDYA#
TXRDYA#
RXRDYA#
RXRDYA#
TXRDYB#
TXRDYB#
RXRDYB#
RXRDYB#
UART_RESET
VCC
TXA
RXA
UART
Channel A
DTRA#
RTSA#
CTSA#
Serial Interface of
RS-232, RS-485
(no connect)
TXB
RXB
UART
Channel B
DTRB#
RTSB#
CTSB#
DSRB#
CDB#
RIB#
OP2B#
RESET
Serial Interface of
RS-232, RS-485
(no connect)
GND
Intel Data Bus Interconnections
2750_int
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
A0
A1
A2
A0
A1
A2
CDA#
A3
CSB#
RIA#
OP2A#
VCC
UART
Channel A
DTRA#
RTSA#
CTSA#
DSRA#
IOR#
VCC
2.25 to 5.5 Volt VCC
TXA
RXA
RS-232 Serial Interface
(no connect)
IOW#
R/W#
TXB
UART_CS#
CSA#
RXB
VCC
UART_IRQ#
INTA
UART
Channel B
INTB
(no connect)
DTRB#
RTSB#
CTSB#
DSRB#
TXRDYA#
TXRDYA#
CDB#
RXRDYA#
RXRDYA#
TXRDYB#
TXRDYB#
RIB#
OP2B#
RXRDYB#
RXRDYB#
UART_RESET#
RESET#
RS-232 Serial Interface
(no connect)
GND
Motorola Data Bus Interconnections
2.2
Device Reset
The RESET input resets the internal registers and the serial interface outputs in both channels to their default
state (see Table 17). An active high pulse of longer than 40 ns duration will be required to activate the reset
function in the device.
8
PRELIMINARY
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
2.3
XR16M2751
Device Identification and Revision
The XR16M2751 provides a Device Identification code and a Device Revision code to distinguish the part from
other devices and revisions. To read the identification code from the part, it is required to set the baud rate
generator registers DLL and DLM both to 0x00 (DLD = 0xXX). Now reading the content of the DLM will provide
0x0A for the XR16M2751 and reading the content of DLL will provide the revision of the part; for example, a
reading of 0x01 means revision A.
2.4
Channel A and B Selection
The UART provides the user with the capability to bi-directionally transfer information between an external
CPU and an external serial communication device. During Intel Bus Mode (16/68# pin connected to VCC), a
logic 0 on chip select pins, CSA# or CSB#, allows the user to select UART channel A or B to configure, send
transmit data and/or unload receive data to/from the UART. Selecting both UARTs can be useful during power
up initialization to write to the same internal registers, but do not attempt to read from both UARTs
simultaneously. Individual channel select functions are shown in Table 1.
TABLE 1: CHANNEL A AND B SELECT IN 16 MODE
CSA#
CSB#
FUNCTION
1
1
UART de-selected
0
1
Channel A selected
1
0
Channel B selected
0
0
Channel A and B selected
During Motorola Bus Mode (16/68# pin connected to GND), the package interface pins are configured for
connection with Motorola, and other popular microprocessor bus types. In this mode the 2751 decodes an
additional address, A3, to select one of the UART ports. The A3 address decode function is used only when in
the Motorola Bus Mode. See Table 2.
TABLE 2: CHANNEL A AND B SELECT IN 68 MODE
2.5
CS#
A3
FUNCTION
1
N/A
UART de-selected
0
0
Channel A selected
0
1
Channel B selected
Channel A and B Internal Registers
Each UART channel in the M2751 has a set of enhanced registers for control, monitoring and data loading and
unloading. The configuration register set is compatible to those already available in the standard single
16C550 and dual ST16C2550. These registers function as data holding registers (THR/RHR), interrupt status
and control registers (ISR/IER), a FIFO control register (FCR), receive line status and control registers (LSR/
LCR), modem status and control registers (MSR/MCR), programmable data rate (clock) divisor registers (DLL/
DLM/DLD), and a user accessible Scratchpad Register (SPR).
Beyond the general 16C2550 features and capabilities, the M2751 offers enhanced feature registers (EMSR,
FLVL, EFR, Xon/Xoff 1, Xon/Xoff 2, FCTR, TRG, FC) that provide automatic RTS and CTS hardware flow
control, Xon/Xoff software flow control, automatic RS-485 half-duplex direction output enable/disable, FIFO
trigger level control, and FIFO level counters. All the register functions are discussed in full detail later in
“Section 3.0, UART INTERNAL REGISTERS” on page 22.
2.6
DMA Mode
The device does not support direct memory access. The DMA Mode (a legacy term) in this document doesn’t
mean “direct memory access” but refers to data block transfer operation. The DMA mode affects the state of
the RXRDY# A/B and TXRDY# A/B output pins. The transmit and receive FIFO trigger levels provide additional
flexibility to the user for block mode operation. The LSR bits 5-6 provide an indication when the transmitter is
9
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
empty or has an empty location(s) for more data. The user can optionally operate the transmit and receive
FIFO in the DMA mode (FCR bit-3=1). When the transmit and receive FIFO are enabled and the DMA mode is
disabled (FCR bit-3 = 0), the M2751 is placed in single-character mode for data transmit or receive operation.
When DMA mode is enabled (FCR bit-3 = 1), the user takes advantage of block mode operation by loading or
unloading the FIFO in a block sequence determined by the programmed trigger level. In this mode, the M2751
sets the TXRDY# pin when the transmit FIFO becomes full, and sets the RXRDY# pin when the receive FIFO
becomes empty. The following table shows their behavior. Also see Figures 19 through 24.
TABLE 3: TXRDY# AND RXRDY# OUTPUTS IN FIFO AND DMA MODE
PINS
FCR BIT-0=0
(FIFO DISABLED)
FCR BIT-0=1 (FIFO ENABLED)
FCR Bit-3 = 0
(DMA Mode Disabled)
RXRDY# A/B LOW = 1 byte.
HIGH = no data.
LOW = at least 1 byte in FIFO.
HIGH = FIFO empty.
TXRDY# A/B LOW = THR empty. LOW = FIFO empty.
HIGH = byte in THR. HIGH = at least 1 byte in FIFO.
2.7
FCR Bit-3 = 1
(DMA Mode Enabled)
HIGH to LOW transition when FIFO reaches the
trigger level, or time-out occurs.
LOW to HIGH transition when FIFO empties.
LOW = FIFO has at least 1 empty location.
HIGH = FIFO is full.
INTA and INTB Outputs
The INTA and INTB interrupt output changes according to the operating mode and enhanced features setup.
Table 4 and 5 summarize the operating behavior for the transmitter and receiver. Also see Figures 19
through 24.
TABLE 4: INTA AND INTB PINS OPERATION FOR TRANSMITTER
Auto RS485
Mode
FCR BIT-0 = 0
(FIFO DISABLED)
FCR BIT-0 = 1 (FIFO ENABLED)
INTA/B Pin
NO
LOW = a byte in THR
HIGH = THR empty
LOW = FIFO above trigger level
HIGH = FIFO below trigger level or FIFO empty
INTA/B Pin
YES
LOW = a byte in THR
HIGH = transmitter empty
LOW = FIFO above trigger level
HIGH = FIFO below trigger level or transmitter empty
TABLE 5: INTA AND INTB PIN OPERATION FOR RECEIVER
FCR BIT-0 = 0
(FIFO DISABLED)
INTA/B Pin
LOW = no data
HIGH = 1 byte
FCR BIT-0 = 1
(FIFO ENABLED)
LOW = FIFO below trigger level
HIGH = FIFO above trigger level
10
PRELIMINARY
P1.0.0
2.8
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
Crystal Oscillator or External Clock Input
The M2751 includes an on-chip oscillator (XTAL1 and XTAL2) to produce a clock for both UART sections in the
device. The CPU data bus does not require this clock for bus operation. The crystal oscillator provides a
system clock to the Baud Rate Generators (BRG) section found in each of the UART. XTAL1 is the input to the
oscillator or external clock buffer input with XTAL2 pin being the output. For programming details, see
““Section 2.9, Programmable Baud Rate Generator with Fractional Divisor” on page 11.”
FIGURE 4. TYPICAL OSCILLATOR CONNECTIONS
XTAL1
XTAL2
R2
500 ΚΩ − 1 ΜΩ
Y1
C1
22-47 pF
R1
0-120 Ω
(Optional)
1.8432 MHz
to
24 MHz
C2
22-47 pF
The on-chip oscillator is designed to use an industry standard microprocessor crystal (parallel resonant,
fundamental frequency with 10-22 pF capacitance load, ESR of 20-120 ohms and 100 ppm frequency
tolerance) connected externally between the XTAL1 and XTAL2 pins (see Figure 4). The programmable Baud
Rate Generator is capable of operating with a crystal oscillator frequency of up to 24 MHz. However, with an
external clock input on XTAL1 pin, it can extend its operation up to 64 MHz (8 Mbps serial data rate) at 3.3V
with an 8X sampling rate. For further reading on the oscillator circuit please see the Application Note DAN108
on the EXAR web site at http://www.exar.com.
2.9
Programmable Baud Rate Generator with Fractional Divisor
Each UART has its own Baud Rate Generator (BRG) with a prescaler for the transmitter and receiver. The
prescaler is controlled by a software bit in the MCR register. The MCR register bit-7 sets the prescaler to divide
the input crystal or external clock by 1 or 4. The output of the prescaler clocks to the BRG. The BRG further
divides this clock by a programmable divisor between 1 and (216 - 0.0625) in increments of 0.0625 (1/16) to
obtain a 16X or 8X sampling clock of the serial data rate. The sampling clock is used by the transmitter for data
bit shifting and receiver for data sampling. The BRG divisor (DLL, DLM and DLD registers) defaults to the value
of ’1’ (DLL = 0x01, DLM = 0x00 and DLD = 0x00) upon reset. Therefore, the BRG must be programmed during
initialization to the operating data rate. The DLL and DLM registers provide the integer part of the divisor and
the DLD register provides the fractional part of the dvisior. Only the four lower bits of the DLD are implemented
and they are used to select a value from 0 (for setting 0000) to 0.9375 or 15/16 (for setting 1111). Programming
the Baud Rate Generator Registers DLL, DLM and DLD provides the capability for selecting the operating data
rate. Table 6 shows the standard data rates available with a 24MHz crystal or external clock at 16X clock rate.
If the pre-scaler is used (MCR bit-7 = 1), the output data rate will be 4 times less than that shown in Table 6. At
8X sampling rate, these data rates would double. Also, when using 8X sampling mode, please note that the bit-
11
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
time will have a jitter (+/- 1/16) whenever the DLD is non-zero and is an odd number. When using a nonstandard data rate crystal or external clock, the divisor value can be calculated with the following equation(s):
Required Divisor (decimal) = (XTAL1 clock frequency / prescaler) / (serial data rate x 16), with 16X mode EMSR[7] = 1
Required Divisor (decimal) = (XTAL1 clock frequency / prescaler / (serial data rate x 8), with 8X mode EMSR[7] = 0
The closest divisor that is obtainable in the M2751 can be calculated using the following formula:
ROUND( (Required Divisor - TRUNC(Required Divisor) )*16)/16 + TRUNC(Required Divisor), where
DLM = TRUNC(Required Divisor) >> 8
DLL = TRUNC(Required Divisor) & 0xFF
DLD = ROUND( (Required Divisor-TRUNC(Required Divisor) )*16)
In the formulas above, please note that:
TRUNC (N) = Integer Part of N. For example, TRUNC (5.6) = 5.
ROUND (N) = N rounded towards the closest integer. For example, ROUND (7.3) = 7 and ROUND (9.9) = 10.
A >> B indicates right shifting the value ’A’ by ’B’ number of bits. For example, 0x78A3 >> 8 = 0x0078.
FIGURE 5. BAUD RATE GENERATOR
To Other
Channels
DLL, DLM and DLD
Registers
Prescaler
Divide by 1
XTAL1
XTAL2
Crystal
Osc/
Buffer
MCR Bit-7=0
(default)
Fractional Baud
Rate Generator
Logic
Prescaler
Divide by 4
12
MCR Bit-7=1
16X or 8X
Sampling
Rate Clock
to Transmitter
and Receiver
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
TABLE 6: TYPICAL DATA RATES WITH A 24 MHZ CRYSTAL OR EXTERNAL CLOCK AT 16X SAMPLING
Required
Output Data
Rate
DIVISOR FOR 16x
Clock
(Decimal)
DIVISOR
OBTAINABLE IN
M2751
DLM PROGRAM
VALUE (HEX)
DLL PROGRAM
VALUE (HEX)
DLD PROGRAM
VALUE (HEX)
DATA ERROR
RATE (%)
400
3750
3750
E
A6
0
0
2400
625
625
2
71
0
0
4800
312.5
312 8/16
1
38
8
0
9600
156.25
156 4/16
0
9C
4
0
10000
150
150
0
96
0
0
19200
78.125
78 2/16
0
4E
2
0
25000
60
60
0
3C
0
0
28800
52.0833
52 1/16
0
34
1
0.04
38400
39.0625
39 1/16
0
27
1
0
50000
30
30
0
1E
0
0
57600
26.0417
26 1/16
0
1A
1
0.08
75000
20
20
0
14
0
0
100000
15
15
0
F
0
0
115200
13.0208
13
0
D
0
0.16
153600
9.7656
9 12/16
0
9
C
0.16
200000
7.5
7 8/16
0
7
8
0
225000
6.6667
6 11/16
0
6
B
0.31
230400
6.5104
6 8/16
0
6
8
0.16
250000
6
6
0
6
0
0
300000
5
5
0
5
0
0
400000
3.75
3 12/16
0
3
C
0
460800
3.2552
3 4/16
0
3
4
0.16
500000
3
3
0
3
0
0
750000
2
2
0
2
0
0
921600
1.6276
1 10/16
0
1
A
0.16
1000000
1.5
1 8/16
0
1
8
0
2.10
Transmitter
The transmitter section comprises of an 8-bit Transmit Shift Register (TSR) and 64 bytes of FIFO which
includes a byte-wide Transmit Holding Register (THR). TSR shifts out every data bit with the 16X/8X internal
clock. A bit time is 16 (8) clock periods (see EMSR bit-7). The transmitter sends the start-bit followed by the
number of data bits, inserts the proper parity-bit if enabled, and adds the stop-bit(s). The status of the FIFO and
TSR are reported in the Line Status Register (LSR bit-5 and bit-6).
13
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
2.10.1
P1.0.0
Transmit Holding Register (THR) - Write Only
The transmit holding register is an 8-bit register providing a data interface to the host processor. The host
writes transmit data byte to the THR to be converted into a serial data stream including start-bit, data bits,
parity-bit and stop-bit(s). The least-significant-bit (Bit-0) becomes first data bit to go out. The THR is the input
register to the transmit FIFO of 64 bytes when FIFO operation is enabled by FCR bit-0. Every time a write
operation is made to the THR, the FIFO data pointer is automatically bumped to the next sequential data
location.
2.10.2
Transmitter Operation in non-FIFO Mode
The host loads transmit data to THR one character at a time. The THR empty flag (LSR bit-5) is set when the
data byte is transferred to TSR. THR flag can generate a transmit empty interrupt (ISR bit-1) when it is enabled
by IER bit-1. The TSR flag (LSR bit-6) is set when TSR becomes completely empty.
FIGURE 6. TRANSMITTER OPERATION IN NON-FIFO MODE
Transmit
Holding
Register
(THR)
Data
Byte
16X or 8X
Clock
(EMSR Bit-7)
THR Interrupt (ISR bit-1)
Enabled by IER bit-1
Transmit Shift Register (TSR)
M
S
B
L
S
B
TXNOFIFO1
2.10.3
Transmitter Operation in FIFO Mode
The host may fill the transmit FIFO with up to 64 bytes of transmit data. The THR empty flag (LSR bit-5) is set
whenever the FIFO is empty. The THR empty flag can generate a transmit empty interrupt (ISR bit-1) when the
amount of data in the FIFO falls below its programmed trigger level. The transmit empty interrupt is enabled by
IER bit-1. The TSR flag (LSR bit-6) is set when TSR/FIFO becomes empty.
FIGURE 7. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE
Transmit
Data Byte
Transm it
FIFO
THR Interrupt (ISR bit-1) falls
below the programmed Trigger
Level and then when becomes
empty. FIFO is Enabled by FCR
bit-0=1
Auto CTS Flow Control (CTS# pin)
Flow Control Characters
(Xoff1/2 and Xon1/2 Reg.
Auto Software Flow Control
16X or 8X Clock
(EMSR bit-7)
Transm it Data Shift Register
(TSR)
T XF IF O 1
14
PRELIMINARY
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
2.11
XR16M2751
Receiver
The receiver section contains an 8-bit Receive Shift Register (RSR) and 64 bytes of FIFO which includes a
byte-wide Receive Holding Register (RHR). The RSR uses the 16X/8X clock (EMSR bit-7) for timing. It verifies
and validates every bit on the incoming character in the middle of each data bit. On the falling edge of a start or
false start bit, an internal receiver counter starts counting at the 16X/8X clock rate. After 8 clocks (or 4 if 8X) the
start bit period should be at the center of the start bit. At this time the start bit is sampled and if it is still a logic
0 it is validated. Evaluating the start bit in this manner prevents the receiver from assembling a false character.
The rest of the data bits and stop bits are sampled and validated in this same manner to prevent false framing.
If there were any error(s), they are reported in the LSR register bits 2-4. Upon unloading the receive data byte
from RHR, the receive FIFO pointer is bumped and the error tags are immediately updated to reflect the status
of the data byte in RHR register. RHR can generate a receive data ready interrupt upon receiving a character
or delay until it reaches the FIFO trigger level. Furthermore, data delivery to the host is guaranteed by a
receive data ready time-out interrupt when data is not received for 4 word lengths as defined by LCR[1:0] plus
12 bits time. This is equivalent to 3.7-4.6 character times. The RHR interrupt is enabled by IER bit-0.
2.11.1
Receive Holding Register (RHR) - Read-Only
The Receive Holding Register is an 8-bit register that holds a receive data byte from the Receive Shift
Register. It provides the receive data interface to the host processor. The RHR register is part of the receive
FIFO of 64 bytes by 11-bits wide, the 3 extra bits are for the 3 error tags to be reported in LSR register. When
the FIFO is enabled by FCR bit-0, the RHR contains the first data character received by the FIFO. After the
RHR is read, the next character byte is loaded into the RHR and the errors associated with the current data
byte are immediately updated in the LSR bits 2-4.
FIGURE 8. RECEIVER OPERATION IN NON-FIFO MODE
16X or 8X C lock
(E M S R bit-7)
R eceive
D ata B yte
and E rrors
R eceive D ata S hift
R egister (R S R )
E rror
T ags in
LS R bits
4:2
R eceive D ata
H olding R egister
(R H R )
D ata B it
V alidation
R e ce ive D a ta C h a ra cte rs
R H R Interrupt (IS R bit-2)
R X F IF O 1
15
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
FIGURE 9. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE
16X or 8X Clock
(EMSR bit-7)
Receive Data Shift
Register (RSR)
Data Bit
Validation
Example
- :RX FIFO trigger level selected at 16
bytes
(See Note Below)
Data falls to
RTS# re-asserts when data falls below the flow
8
control trigger level to restart remote transmitter.
Error Tags
(64-sets)
64 bytes by 11-bit
wide
FIFO
Receive
Data FIFO
Enable by EFR bit-6=1, MCR bit-1.
FIFO
Trigger=16
Error Tags in
LSR bits 4:2
Data fills to
24
Receive Data
Byte and Errors
Receive Data Characters
RHR Interrupt (ISR bit-2) programmed for
desired FIFO trigger level.
FIFO is Enabled by FCR bit-0=1
RTS# de-asserts when data fills above the flow
control trigger level to suspend remote transmitter.
Enable by EFR bit-6=1, MCR bit-1.
Receive
Data
RXFIFO1
NOTE: Table-B selected as Trigger Table for Figure 9 (Table 11).
2.12
Auto RTS (Hardware) Flow Control
Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS#
output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control
features is enabled to fit specific application requirement (see Figure 10):
• Enable auto RTS flow control using EFR bit-6.
• The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled).
If using the Auto RTS interrupt:
• Enable RTS interrupt through IER bit-6 (after setting EFR bit-4). The UART issues an interrupt when the
RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1.
2.13
Auto RTS Hysteresis
The M2751 has a new feature that provides flow control trigger hysteresis while maintaining compatibility with
the XR16C850, ST16C650A and ST16C550 family of UARTs. With the Auto RTS function enabled, an interrupt
is generated when the receive FIFO reaches the programmed RX trigger level. The RTS# pin will not be forced
HIGH (RTS off) until the receive FIFO reaches the upper limit of the hysteresis level. The RTS# pin will return
LOW after the RX FIFO is unloaded to the lower limit of the hysteresis level. Under the above described
conditions, the M2751 will continue to accept data until the receive FIFO gets full. The Auto RTS function is
initiated when the RTS# output pin is asserted LOW (RTS On). Table 14 shows the complete details for the
Auto RTS# Hysteresis levels. Please note that this table is for programmable trigger levels only (Table D). The
hysteresis values for Tables A-C are the next higher and next lower trigger levels in the corresponding table.
16
PRELIMINARY
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
2.14
XR16M2751
Auto CTS Flow Control
Automatic CTS flow control is used to prevent data overrun to the remote receiver FIFO. The CTS# input is
monitored to suspend/restart the local transmitter. The auto CTS flow control feature is selected to fit specific
application requirement (see Figure 10):
• Enable auto CTS flow control using EFR bit-7.
If using the Auto CTS interrupt:
• Enable CTS interrupt through IER bit-7 (after setting EFR bit-4). The UART issues an interrupt when the
CTS# pin is de-asserted (HIGH): ISR bit-5 will be set to 1, and UART will suspend transmission as soon as
the stop bit of the character in process is shifted out. Transmission is resumed after the CTS# input is reasserted (LOW), indicating more data may be sent.
FIGURE 10. AUTO RTS AND CTS FLOW CONTROL OPERATION
Local UART
UARTA
Remote UART
UARTB
RXA
Receiver FIFO
Trigger Reached
RTSA#
Auto RTS
Trigger Level
Receiver FIFO
Trigger Reached
RTSB#
Assert RTS# to Begin
Transmission
1
ON
Auto RTS
Trigger Level
10
OFF
ON
7
2
CTSB#
Auto CTS
Monitor
RXB
CTSA#
Auto CTS
Monitor
Transmitter
CTSB#
TXA
Transmitter
RTSA#
TXB
ON
3
8
OFF
6
Suspend
11
ON
TXB
Data Starts
4
Restart
9
RXA FIFO
INTA
(RXA FIFO
Interrupt)
Receive
RX FIFO
Data
Trigger Level
5
RTS High
Threshold
RTS Low
Threshold
12
RX FIFO
Trigger Level
RTSCTS1
The local UART (UARTA) starts data transfer by asserting RTSA# (1). RTSA# is normally connected to CTSB# (2) of
remote UART (UARTB). CTSB# allows its transmitter to send data (3). TXB data arrives and fills UARTA receive FIFO
(4). When RXA data fills up to its receive FIFO trigger level, UARTA activates its RXA data ready interrupt (5) and continues to receive and put data into its FIFO. If interrupt service latency is long and data is not being unloaded, UARTA
monitors its receive data fill level to match the upper threshold of RTS delay and de-assert RTSA# (6). CTSB# follows
(7) and request UARTB transmitter to suspend data transfer. UARTB stops or finishes sending the data bits in its transmit shift register (8). When receive FIFO data in UARTA is unloaded to match the lower threshold of RTS delay (9),
UARTA re-asserts RTSA# (10), CTSB# recognizes the change (11) and restarts its transmitter and data flow again until
next receive FIFO trigger (12). This same event applies to the reverse direction when UARTA sends data to UARTB
with RTSB# and CTSA# controlling the data flow.
17
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
2.15
P1.0.0
Auto Xon/Xoff (Software) Flow Control
When software flow control is enabled (See Table 16), the M2751 compares one or two sequential receive
data characters with the programmed Xon or Xoff-1,2 character value(s). If receive character(s) (RX) match the
programmed values, the M2751 will halt transmission (TX) as soon as the current character has completed
transmission. When a match occurs, the Xoff (if enabled via IER bit-5) flag will be set and the interrupt output
pin will be activated. Following a suspension due to a match of the Xoff character, the M2751 will monitor the
receive data stream for a match to the Xon-1,2 character. If a match is found, the M2751 will resume operation
and clear the flags (ISR bit-4).
Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to 0x00. Following reset the user can
write any Xon/Xoff value desired for software flow control. Different conditions can be set to detect Xon/Xoff
characters (See Table 16) and suspend/resume transmissions. When double 8-bit Xon/Xoff characters are
selected, the M2751 compares two consecutive receive characters with two software flow control 8-bit values
(Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions accordingly. Under the above described flow control
mechanisms, flow control characters are not placed (stacked) in the user accessible RX data buffer or FIFO.
In the event that the receive buffer is overfilling and flow control needs to be executed, the M2751
automatically sends an Xoff message via the serial TX output to the remote modem. The M2751 sends the
Xoff-1,2 characters two-character times (= time taken to send two characters at the programmed baud rate)
after the receive FIFO crosses the programmed trigger level (for all trigger tables). To clear this condition, the
M2751 will transmit the programmed Xon-1,2 characters as soon as receive FIFO is less than one trigger level
below the programmed trigger level (for Trigger Tables A, B, and C) or when receive FIFO is less than the
trigger level minus the hysteresis value (for Trigger Table D). This hysteresis value is the same as the Auto
RTS Hysteresis value in Table 15. Table 7 below explains this when Trigger Table-B (See Table 11) is
selected.
TABLE 7: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL
RX TRIGGER LEVEL
INT PIN ACTIVATION
XOFF CHARACTER(S) SENT
(CHARACTERS IN RX FIFO)
XON CHARACTER(S) SENT
(CHARACTERS IN RX FIFO)
8
8
8*
0
16
16
16*
8
24
24
24*
16
28
28
28*
24
* After the trigger level is reached, an xoff character is sent after a short span of time (= time required to send 2
characters); for example, after 2.083ms has elapsed for 9600 baud and 10-bit word length setting.
2.16
Special Character Detect
A special character detect feature is provided to detect an 8-bit character when bit-5 is set in the Enhanced
Feature Register (EFR). When this character (Xoff2) is detected, it will be placed in the FIFO along with normal
incoming RX data.
The M2751 compares each incoming receive character with Xoff-2 data. If a match exists, the received data
will be transferred to FIFO and ISR bit-4 will be set to indicate detection of special character. Although the
Internal Register Table shows Xon, Xoff Registers with eight bits of character information, the actual number of
bits is dependent on the programmed word length. Line Control Register (LCR) bits 0-1 defines the number of
character bits, i.e., either 5 bits, 6 bits, 7 bits, or 8 bits. The word length selected by LCR bits 0-1 also
determines the number of bits that will be used for the special character comparison. Bit-0 in the Xon, Xoff
Registers corresponds with the LSB bit for the receive character.
2.17
Auto RS485 Half-duplex Control
The auto RS485 half-duplex direction control changes the behavior of the transmitter when enabled by FCTR
bit-3. By default, it de-asserts RTS# (HIGH) output following the last stop bit of the last character that has been
transmitted. This helps in turning around the transceiver to receive the remote station’s response. When the
host is ready to transmit next polling data packet again, it only has to load data bytes to the transmit FIFO. The
18
PRELIMINARY
P1.0.0
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
transmitter automatically re-asserts RTS# (LOW) output prior to sending the data. The RS485 half-duplex
direction control output can be inverted by enabling EMSR bit-3.
2.18
Infrared Mode
The M2751 UART includes the infrared encoder and decoder compatible to the IrDA (Infrared Data
Association) version 1.0. The IrDA 1.0 standard that stipulates the infrared encoder sends out a 3/16 of a bit
wide HIGH-pulse for each “0” bit in the transmit data stream. This signal encoding reduces the on-time of the
infrared LED, hence reduces the power consumption. See Figure 11 below.
The infrared encoder and decoder are enabled by setting MCR register bit-6 to a ‘1’. When the infrared feature
is enabled, the transmit data output, TX, idles at logic zero level. Likewise, the RX input assumes an idle level
of logic zero from a reset and power up, see Figure 11.
Typically, the wireless infrared decoder receives the input pulse from the infrared sensing diode on the RX pin.
Each time it senses a light pulse, it returns a logic 1 to the data bit stream. However, this is not true with some
infrared modules on the market which indicate a logic 0 by a light pulse. So the M2751 has a provision to invert
the input polarity to accommodate this. In this case user can enable FCTR bit-2 to invert the input signal.
FIGURE 11. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING
TX Data
0
Stop
Start
Character
Data Bits
1
0
1
0
1
0
1
1
0
Transmit
IR Pulse
(TX Pin)
1/2 Bit Time
Bit Time
3/16 Bit Time
IrEncoder-1
Receive
IR Pulse
(RX pin)
Bit Time
1/16 Clock Delay
1
0
1
0
0
Data Bits
1 1
0
1
Stop
0
Start
RX Data
Character
IRdecoder-
19
XR16M2751
PRELIMINARY
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
2.19
P1.0.0
Sleep Mode with Wake-Up Indicator and PowerSave Feature
The M2751 supports low voltage system designs, hence, a sleep mode with auto wake-up and PowerSave
feature is included to reduce power consumption when the device is not actively used.
2.19.1
Sleep Mode
All of these conditions must be satisfied for the M2751 to enter sleep mode:
■
■
■
■
no interrupts pending for both channels of the 2751 (ISR bit-0 = 1)
sleep mode of both channels are enabled (IER bit-4 = 1)
modem inputs are not toggling (MSR bits 0-3 = 0)
RX input pins are idling HIGH
The M2751 stops its crystal oscillator to conserve power in the sleep mode. User can check the XTAL2 pin for
no clock output as an indication that the device has entered the sleep mode.
The M2751 resumes normal operation by any of the following when PowerSave mode is disabled (pin 12 at
ground):
■
■
■
a receive data start bit transition (HIGH to LOW)
a data byte is loaded to the transmitter, THR or FIFO
a change of logic state on any of the modem or general purpose serial inputs: CTS#, DSR#, CD#, RI#
If the sleep mode is enabled and the 2751 is awakened by one of the conditions described above, an interrupt
is issued by the 2751 to signal to the CPU that it is awake. The lower nibble of the interrupt source register
(ISR) will read a value of 0x1 for this interrupt and reading the ISR clears this interrupt. Since the same value
(0x1) is also used to indicate no pending interrupt, users should exercise caution while using the sleep mode.
The 2751 will return to the sleep mode automatically after all interrupting conditions have been serviced and
cleared. If the 2751 is awakened by the modem inputs, a read to the MSR is required to reset the modem
inputs. In any case, the sleep mode will not be entered while an interrupt is pending from channel A or B. The
2751 will stay in the sleep mode of operation until it is disabled by setting IER bit-4 to a logic 0.
A word of caution: owing to the starting up delay of the crystal oscillator after waking up from sleep mode, the
first few receive characters may be lost. The number of characters lost during the restart also depends on your
operating data rate. More characters are lost when operating at higher data rate. Also, it is important to keep
RX A/B inputs idling HIGH or “marking” condition during sleep mode to avoid receiving a “break” condition
upon the restart. This may occur when the external interface transceivers (RS-232, RS-485 or another type)
are also put to sleep mode and cannot maintain the “marking” condition. To avoid this, the designer can use a
47k-100k ohm pull-up resistor on the RXA and RXB pins.
2.19.2
PowerSave Feature
If the address lines, data bus lines, IOW#, IOR#, CSA#, CSB#, and modem input lines remain steady when the
2751 is in sleep mode, the maximum current will be in the microamp range as specified in the DC Electrical
Characteristics on page 40. If the input lines are floating or are toggling while the 2751 is in sleep mode, the
current can be up to 100 times more. If not using the PowerSave feature, then an external buffer would be
required to keep the address and data bus lines from toggling or floating to achieve the low current. But if the
PowerSave feature is enabled (pin 12 connected to VCC), this will eliminate the need for an external buffer by
internally isolating the address, data and control signals (see Figure 1 on page 1) from other bus activities that
could cause wasteful power drain. The 2751 enters PowerSave mode when pin 12 is connected to VCC and
the 2751 is in sleep mode (see Sleep Mode section above).
Since PowerSave mode isolates the address, data and control signals, the device will wake-up by:
■
■
a receive data start bit transition (HIGH to LOW)
a change of logic state on any of the modem or general purpose serial inputs: CTS#, DSR#, CD#, RI#
The 2751 will return to the PowerSave mode automatically after a read to the MSR (to reset the modem inputs)
and all interrupting conditions have been serviced and cleared. The 2751 will stay in the PowerSave mode of
operation until it is disabled by setting IER bit-4 to a logic 0 and/or the PowerSave pin is connected to GND.
20
PRELIMINARY
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
2.20
XR16M2751
Internal Loopback
The M2751 UART provides an internal loopback capability for system diagnostic purposes. The internal
loopback mode is enabled by setting MCR register bit-4 to logic 1. All regular UART functions operate normally.
Figure 12 shows how the modem port signals are re-configured. Transmit data from the transmit shift register
output is internally routed to the receive shift register input allowing the system to receive the same data that it
was sending. The TX, RTS# and DTR# pins are held while the CTS#, DSR# CD# and RI# inputs are ignored.
Caution: the RX input pin must be held HIGH during loopback test else upon exiting the loopback test the
UART may detect and report a false “break” signal. Also, Auto RTS/CTS flow control is not supported during
internal loopback.
FIGURE 12. INTERNAL LOOP BACK IN CHANNEL A AND B
VCC
TXA/TXB
Transmit Shift Register
(THR/FIFO)
Receive Shift Register
(RHR/FIFO)
RXA/RXB
VCC
RTSA#/RTSB#
RTS#
Modem / General Purpose Control Logic
Internal Data Bus Lines and Control Signals
MCR bit-4=1
CTS#
CTSA#/CTSB#
VCC
DTRA#/DTRB#
DTR#
DSR#
DSRA#/DSRB#
OP1#
RI#
RIA#/RIB#
VCC
OP2A#/OP2B#
OP2#
CD#
CDA#/CDB#
21
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
3.0 UART INTERNAL REGISTERS
Each of the UART channel in the M2751 has its own set of configuration registers selected by address lines
A0, A1 and A2 with CSA# or CSB# selecting the channel. The complete register set is shown on Table 8 and
Table 9.
TABLE 8: UART CHANNEL A AND B UART INTERNAL REGISTERS
ADDRESSES
A2 A1 A0
REGISTER
READ/WRITE
COMMENTS
LCR[7] = 0
16C550 COMPATIBLE REGISTERS
0
0 0
RHR - Receive Holding Register
THR - Transmit Holding Register
Read-only
Write-only
0
0 0
DLL - Divisor LSB
Read/Write
0
0 1
DLM - Divisor MSB
Read/Write
0
1 0
DLD - Divisor Fractional
Read/Write
LCR[7] = 1, LCR ≠ 0xBF,
EFR[4] = 1
0
0 0
DREV - Device Revision Code
Read-only
0
0 1
DVID - Device Identification Code
Read-only
DLL, DLM = 0x00,
LCR[7] = 1, LCR ≠ 0xBF
0
0 1
IER - Interrupt Enable Register
Read/Write
LCR[7] = 0
0
1 0
ISR - Interrupt Status Register
FCR - FIFO Control Register
Read-only
Write-only
LCR ≠ 0xBF
0
1 1
LCR - Line Control Register
Read/Write
1
0 0
MCR - Modem Control Register
Read/Write
1
0 1
LSR - Line Status Register
Read-only
1
1 0
MSR - Modem Status Register
Read-only
1
1 1
SPR - Scratch Pad Register
Read/Write
1
1 1
FLVL - RX/TX FIFO Level Counter Register
Read-only
1
1 1
EMSR - Enhanced Mode Select Register
Write-only
LCR[7] = 1, LCR ≠ 0xBF
LCR ≠ 0xBF
LCR ≠ 0xBF, FCTR[6] = 0
LCR ≠ 0xBF, FCTR[6] = 1
ENHANCED REGISTERS
0
0 0
TRG - RX/TX FIFO Trigger Level Register
FC - RX/TX FIFO Level Counter Register
Write-only
Read-only
0
0 1
FCTR - Feature Control Register
Read/Write
0
1 0
EFR - Enhanced Function Register
Read/Write
1
0 0
Xon-1 - Xon Character 1
Read/Write
1
0 1
Xon-2 - Xon Character 2
Read/Write
1
1 0
Xoff-1 - Xoff Character 1
Read/Write
1
1 1
Xoff-2 - Xoff Character 2
Read/Write
22
LCR = 0xBF
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
.
TABLE 9: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1
ADDRESS
A2-A0
REG
NAME
READ/
WRITE
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
COMMENT
16C550 Compatible Registers
000
RHR
RD
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
000
THR
WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
001
IER
RD/WR
0/
0/
0/
0/
CTS Int. RTS Int.
Enable Enable
Xoff Int.
Enable
Sleep
Mode
Enable
FIFOs
FIFOs
Enabled Enabled
0/
0/
INT
Source
Bit-5
INT
Source
Bit-4
0/
0/
010
010
ISR
FCR
RD
WR
RX FIFO RX FIFO
Trigger Trigger
TX FIFO TX FIFO
Trigger Trigger
011
LCR
RD/WR
Divisor
Enable
Set TX
Break
Set Parity
100
MCR
RD/WR
0/
0/
0/
BRG
Prescaler
Even
Parity
Modem RX Line
TX
RX
Stat. Int.
Stat.
Empty
Data
Enable
Int.
Int
Int.
Enable Enable Enable
INT
Source
Bit-3
INT
INT
INT
Source Source Source
Bit-2
Bit-1
Bit-0
DMA
Mode
Enable
TX
FIFO
Reset
Parity
Enable
Stop
Bits
LCR ≠ 0xBF
RX
FIFO
Reset
FIFOs
Enable
Word
Word
Length Length
Bit-1
Bit-0
Internal OP2#/INT Rsrvd RTS# DTR#
Lopback Output (OP1#) Output Output
IR Mode XonAny Enable
Enable
Control Control
ENable
101
LSR
RD
RX FIFO
Global
Error
THR &
TSR
Empty
THR
Empty
RX
Break
RX Framing Error
RX
Parity
Error
RX
Overrun
Error
RX
Data
Ready
110
MSR
RD
CD#
Input
RI#
Input
DSR#
Input
CTS#
Input
Delta
CD#
Delta
RI#
Delta
DSR#
Delta
CTS#
111
SPR
RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
111
EMSR
WR
16X
Sampling
Rate
Mode
LSR
Error
Interrupt.
Imd/Dly#
Auto
RTS
Hyst.
bit-3
Auto
RTS
Hyst.
bit-2
Auto
RS485
Output
Inversion
Rsrvd
Rx/Tx
FIFO
Count
Rx/Tx
FIFO
Count
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
111
FLVL
RD
LCR[7]=0
23
LCR ≠ 0xBF
LCR ≠ 0xBF
FCTR[6]=0
LCR ≠ 0xBF
FCTR[6]=1
Bit-1
Bit-0
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
TABLE 9: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1
ADDRESS
A2-A0
REG
NAME
READ/
WRITE
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
COMMENT
LCR[7]=1
LCR ≠ 0xBF
Baud Rate Generator Divisor
000
DLL
RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
001
DLM
RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
010
DLD
RD/WR
0
0
0
0
Bit-3
Bit-2
Bit-1
Bit-0
LCR[7]=1
LCR ≠ 0xBF
EFR[4] = 1
000
DREV
RD
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
001
DVID
RD
0
0
0
0
1
0
1
0
LCR[7]=1
LCR ≠ 0xBF
DLL=0x00
DLM=0x00
Enhanced Registers
000
TRG
WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
000
FC
RD
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
RX/TX
Mode
SCPAD
Swap
Trig
Table
Bit-1
Trig
Table
Bit-0
Auto
RS485
Direction
Control
RX IR
Input
Inv.
Auto
RTS
Hyst
Bit-1
Auto
RTS
Hyst
Bit-0
Auto
CTS
Enable
Auto
RTS
Enable
Special
Char
Select
Enable
Software
Flow
Cntl
Bit-2
Software
Flow
Cntl
Bit-1
Software
Flow
Cntl
Bit-0
DLD
Software
Flow
Cntl
Bit-3
001
010
FCTR RD/WR
EFR
RD/WR
IER [7:4],
ISR [5:4],
FCR[5:4],
MCR[7:5],
100
XON1 RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
101
XON2 RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
110
XOFF1 RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
111
XOFF2 RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
LCR=0XBF
4.0 INTERNAL REGISTER DESCRIPTIONS
4.1
Receive Holding Register (RHR) - Read- Only
SEE”RECEIVER” ON PAGE 15.
4.2
Transmit Holding Register (THR) - Write-Only
SEE”TRANSMITTER” ON PAGE 13.
4.3
Interrupt Enable Register (IER) - Read/Write
The Interrupt Enable Register (IER) masks the interrupts from receive data ready, transmit empty, line status
and modem status registers. These interrupts are reported in the Interrupt Status Register (ISR).
24
PRELIMINARY
P1.0.0
4.3.1
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
IER versus Receive FIFO Interrupt Mode Operation
When the receive FIFO (FCR BIT-0 = 1) and receive interrupts (IER BIT-0 = 1) are enabled, the RHR interrupts
(see ISR bits 2 and 3) status will reflect the following:
A. The receive data available interrupts are issued to the host when the FIFO has reached the programmed
trigger level. It will be cleared when the FIFO drops below the programmed trigger level.
B. FIFO level will be reflected in the ISR register when the FIFO trigger level is reached. Both the ISR register
status bit and the interrupt will be cleared when the FIFO drops below the trigger level.
C. The receive data ready bit (LSR BIT-0) is set as soon as a character is transferred from the shift register to
the receive FIFO. It is reset when the FIFO is empty.
4.3.2
IER versus Receive/Transmit FIFO Polled Mode Operation
When FCR BIT-0 equals a logic 1 for FIFO enable; resetting IER bits 0-3 enables the XR16M2751 in the FIFO
polled mode of operation. Since the receiver and transmitter have separate bits in the LSR either or both can
be used in the polled mode by selecting respective transmit or receive control bit(s).
A. LSR BIT-0 indicates there is data in RHR or RX FIFO.
B. LSR BIT-1 indicates an overrun error has occurred and that data in the FIFO may not be valid.
C. LSR BIT 2-4 provides the type of receive data errors encountered for the data byte in RHR, if any.
D. LSR BIT-5 indicates THR is empty.
E. LSR BIT-6 indicates when both the transmit FIFO and TSR are empty.
F. LSR BIT-7 indicates a data error in at least one character in the RX FIFO.
IER[0]: RHR Interrupt Enable
The receive data ready interrupt will be issued when RHR has a data character in the non-FIFO mode or when
the receive FIFO has reached the programmed trigger level in the FIFO mode.
• Logic 0 = Disable the receive data ready interrupt (default).
• Logic 1 = Enable the receiver data ready interrupt.
IER[1]: THR Interrupt Enable
This bit enables the Transmit Ready interrupt which is issued whenever the THR becomes empty in the nonFIFO mode or when data in the FIFO falls below the programmed trigger level in the FIFO mode. If the THR is
empty when this bit is enabled, an interrupt will be generated.
• Logic 0 = Disable Transmit Ready interrupt (default).
• Logic 1 = Enable Transmit Ready interrupt.
IER[2]: Receive Line Status Interrupt Enable
If any of the LSR register bits 1, 2, 3 or 4 is a logic 1, it will generate an interrupt to inform the host controller
about the error status of the current data byte in FIFO. LSR bit-1 generates an interrupt immediately when the
character has been received. LSR bits 2-4 generate an interrupt when the character with errors is read out of
the FIFO (default). Instead, LSR bits 2-4 can be programmed to generate an interrupt immediately, by setting
EMSR bit-6 to a logic 1.
• Logic 0 = Disable the receiver line status interrupt (default).
• Logic 1 = Enable the receiver line status interrupt.
IER[3]: Modem Status Interrupt Enable
• Logic 0 = Disable the modem status register interrupt (default).
• Logic 1 = Enable the modem status register interrupt.
IER[4]: Sleep Mode Enable (requires EFR bit-4 = 1)
• Logic 0 = Disable Sleep Mode (default).
• Logic 1 = Enable Sleep Mode. See Sleep Mode section for further details.
25
XR16M2751
PRELIMINARY
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
IER[5]: Xoff Interrupt Enable (requires EFR bit-4=1)
• Logic 0 = Disable the software flow control, receive Xoff interrupt (default).
• Logic 1 = Enable the software flow control, receive Xoff interrupt. See Software Flow Control section for
details.
IER[6]: RTS# Output Interrupt Enable (requires EFR bit-4=1)
• Logic 0 = Disable the RTS# interrupt (default).
• Logic 1 = Enable the RTS# interrupt. The UART issues an interrupt when the RTS# pin makes a transition
from low to high.
IER[7]: CTS# Input Interrupt Enable (requires EFR bit-4=1)
• Logic 0 = Disable the CTS# interrupt (default).
• Logic 1 = Enable the CTS# interrupt. The UART issues an interrupt when CTS# pin makes a transition from
low to high.
4.4
Interrupt Status Register (ISR) - Read-Only
The UART provides multiple levels of prioritized interrupts to minimize external software interaction. The
Interrupt Status Register (ISR) provides the user with six interrupt status bits. Performing a read cycle on the
ISR will give the user the current highest pending interrupt level to be serviced, others are queued up to be
serviced next. No other interrupts are acknowledged until the pending interrupt is serviced. The Interrupt
Source Table, Table 10, shows the data values (bit 0-5) for the interrupt priority levels and the interrupt sources
associated with each of these interrupt levels.
4.4.1
Interrupt Generation:
• LSR is by any of the LSR bits 1, 2, 3 and 4.
• RXRDY is by RX trigger level.
• RXRDY Time-out is by a 4-char plus 12 bits delay timer.
• TXRDY is by TX trigger level or TX FIFO empty (or transmitter empty in auto RS-485 control).
• MSR is by any of the MSR bits 0, 1, 2 and 3.
• Receive Xoff/Special character is by detection of a Xoff or Special character.
• CTS# is when its transmitter toggles the input pin (from LOW to HIGH) during auto CTS flow control.
• RTS# is when its receiver toggles the output pin (from LOW to HIGH) during auto RTS flow control.
• Wake-up Indicator is when the UART comes out of sleep mode.
4.4.2
Interrupt Clearing:
• LSR interrupt is cleared by a read to the LSR register.
• RXRDY interrupt is cleared by reading data until FIFO falls below the trigger level.
• RXRDY Time-out interrupt is cleared by reading RHR.
• TXRDY interrupt is cleared by a read to the ISR register or writing to THR.
• MSR interrupt is cleared by a read to the MSR register.
• Xoff interrupt is cleared by a read to ISR or when Xon character(s) is received.
• Special character interrupt is cleared by a read to ISR or after the next character is received.
• RTS# and CTS# flow control interrupts are cleared by a read to the MSR register.
• Wake-up Indicator is cleared by a read to the ISR register.
26
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
]
TABLE 10: INTERRUPT SOURCE AND PRIORITY LEVEL
PRIORITY
ISR REGISTER STATUS BITS
SOURCE OF INTERRUPT
LEVEL
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
1
0
0
0
1
1
0
LSR (Receiver Line Status Register)
2
0
0
1
1
0
0
RXRDY (Receive Data Time-out)
3
0
0
0
1
0
0
RXRDY (Received Data Ready)
4
0
0
0
0
1
0
TXRDY (Transmit Ready)
5
0
0
0
0
0
0
MSR (Modem Status Register)
6
0
1
0
0
0
0
RXRDY (Received Xoff or Special character)
7
1
0
0
0
0
0
CTS#, RTS# change of state
-
0
0
0
0
0
1
None (default) or Wake-up Indicator
ISR[0]: Interrupt Status
• Logic 0 = An interrupt is pending and the ISR contents may be used as a pointer to the appropriate interrupt
service routine.
• Logic 1 = No interrupt pending (default condition) or the device has come out of sleep mode.
ISR[3:1]: Interrupt Status
These bits indicate the source for a pending interrupt at interrupt priority levels (See Interrupt Source
Table 10).
ISR[4]: Xoff/Xon or Special Character Interrupt Status
This bit is enabled when EFR bit-4 is set to a logic 1. ISR bit-4 indicates that the receiver detected a data match
of the Xoff character(s). If this is an Xoff/Xon interrupt, it can be cleared by a read to the ISR. If it is a special
character interrupt, it can be cleared by reading ISR or it will automatically clear after the next character is
received.
ISR[5]: RTS#/CTS# Interrupt Status
This bit is enabled when EFR bit-4 is set to a logic 1. ISR bit-5 indicates that the CTS# or RTS# has been deasserted.
ISR[7:6]: FIFO Enable Status
These bits are set to a logic 0 when the FIFOs are disabled. They are set to a logic 1 when the FIFOs are
enabled.
4.5
FIFO Control Register (FCR) - Write-Only
This register is used to enable the FIFOs, clear the FIFOs, set the transmit/receive FIFO trigger levels, and
select the DMA mode. The DMA, and FIFO modes are defined as follows:
FCR[0]: TX and RX FIFO Enable
• Logic 0 = Disable the transmit and receive FIFO (default).
• Logic 1 = Enable the transmit and receive FIFOs. This bit must be set to logic 1 when other FCR bits are
written or they will not be programmed.
FCR[1]: RX FIFO Reset
This bit is only active when FCR bit-0 is a ‘1’.
• Logic 0 = No receive FIFO reset (default)
• Logic 1 = Reset the receive FIFO pointers and FIFO level counter logic (the receive shift register is not
cleared or altered). This bit will return to a logic 0 after resetting the FIFO.
27
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
FCR[2]: TX FIFO Reset
This bit is only active when FCR bit-0 is a ‘1’.
• Logic 0 = No transmit FIFO reset (default).
• Logic 1 = Reset the transmit FIFO pointers and FIFO level counter logic (the transmit shift register is not
cleared or altered). This bit will return to a logic 0 after resetting the FIFO.
FCR[3]: DMA Mode Select
Controls the behavior of the TXRDY# and RXRDY# pins. See DMA operation section for details.
• Logic 0 = Normal Operation (default).
• Logic 1 = DMA Mode.
FCR[5:4]: Transmit FIFO Trigger Select
(logic 0 = default, TX trigger level = 1)
These 2 bits set the trigger level for the transmit FIFO. The UART will issue a transmit interrupt when the
number of characters in the FIFO falls below the selected trigger level, or when it gets empty in case that the
FIFO did not get filled over the trigger level on last re-load. Table 11 below shows the selections. EFR bit-4
must be set to ‘1’ before these bits can be accessed. Note that the receiver and the transmitter cannot use
different trigger tables. Whichever selection is made last applies to both the RX and TX side.
FCR[7:6]: Receive FIFO Trigger Select
(logic 0 = default, RX trigger level =1)
The FCTR Bits 5-4 are associated with these 2 bits. These 2 bits are used to set the trigger level for the receive
FIFO. The UART will issue a receive interrupt when the number of the characters in the FIFO crosses the
trigger level. Table 11 shows the complete selections. Note that the receiver and the transmitter cannot use
different trigger tables. Whichever selection is made last applies to both the RX and TX side.
TABLE 11: TRANSMIT AND RECEIVE FIFO TRIGGER TABLE AND LEVEL SELECTION
TRIGGER
TABLE
FCTR
BIT-5
FCTR
BIT-4
Table-A
0
0
FCR
BIT-7
0
0
1
1
Table-B
0
FCR
BIT-6
FCR
BIT-5
FCR
BIT-4
0
0
0
1
0
1
1
TRANSMIT
TRIGGER
LEVEL
1 (default)
1 (default)
4
8
14
0
0
1
1
0
0
1
1
RECEIVE
TRIGGER LEVEL
0
1
0
1
0
1
0
1
16
8
24
30
8
16
24
28
28
COMPATIBILITY
16C550, 16C2550,
16C2552, 16C554,
16C580
16C650A
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
TABLE 11: TRANSMIT AND RECEIVE FIFO TRIGGER TABLE AND LEVEL SELECTION
TRIGGER
TABLE
FCTR
BIT-5
FCTR
BIT-4
Table-C
1
0
Table-D
4.6
1
1
FCR
BIT-7
FCR
BIT-6
0
0
1
1
0
1
0
1
X
X
FCR
BIT-5
FCR
BIT-4
0
0
1
1
0
1
0
1
RECEIVE
TRIGGER LEVEL
TRANSMIT
TRIGGER
LEVEL
8
16
32
56
COMPATIBILITY
16C654
8
16
56
60
X
X
Programmable Programmable 16L2752, 16C2850,
16C2852, 16C850,
via TRG
via TRG
16C854, 16C864
register.
register.
FCTR[7] = 0.
FCTR[7] = 1.
Line Control Register (LCR) - Read/Write
The Line Control Register is used to specify the asynchronous data communication format. The word or
character length, the number of stop bits, and the parity are selected by writing the appropriate bits in this
register.
LCR[1:0]: TX and RX Word Length Select
These two bits specify the word length to be transmitted or received.
BIT-1
BIT-0
WORD LENGTH
0
0
5 (default)
0
1
6
1
0
7
1
1
8
LCR[2]: TX and RX Stop-bit Length Select
The length of stop bit is specified by this bit in conjunction with the programmed word length.
LENGTH
STOP BIT LENGTH
(BIT TIME(S))
0
5,6,7,8
1 (default)
1
5
1-1/2
1
6,7,8
2
BIT-2
WORD
29
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
LCR[3]: TX and RX Parity Select
Parity or no parity can be selected via this bit. The parity bit is a simple way used in communications for data
integrity check. See Table 12 for parity selection summary below.
• Logic 0 = No parity.
• Logic 1 = A parity bit is generated during the transmission while the receiver checks for parity error of the
data character received.
LCR[4]: TX and RX Parity Select
If the parity bit is enabled with LCR bit-3 set to a logic 1, LCR bit-4 selects the even or odd parity format.
• Logic 0 = ODD Parity is generated by forcing an odd number of logic 1’s in the transmitted character. The
receiver must be programmed to check the same format (default).
• Logic 1 = EVEN Parity is generated by forcing an even number of logic 1’s in the transmitted character. The
receiver must be programmed to check the same format.
LCR[5]: TX and RX Parity Select
If the parity bit is enabled, LCR BIT-5 selects the forced parity format.
• LCR BIT-5 = logic 0, parity is not forced (default).
• LCR BIT-5 = logic 1 and LCR BIT-4 = logic 0, parity bit is forced to a logical 1 for the transmit and receive
data.
• LCR BIT-5 = logic 1 and LCR BIT-4 = logic 1, parity bit is forced to a logical 0 for the transmit and receive
data.
TABLE 12: PARITY SELECTION
LCR BIT-5 LCR BIT-4 LCR BIT-3
PARITY SELECTION
X
X
0
No parity
0
0
1
Odd parity
0
1
1
Even parity
1
0
1
Force parity to mark, “1”
1
1
1
Forced parity to space, “0”
LCR[6]: Transmit Break Enable
When enabled, the Break control bit causes a break condition to be transmitted (the TX output is forced to a
“space", LOW state). This condition remains, until disabled by setting LCR bit-6 to a logic 0.
• Logic 0 = No TX break condition (default).
• Logic 1 = Forces the transmitter output (TX) to a “space”, LOW, for alerting the remote receiver of a line
break condition.
LCR[7]: Baud Rate Divisors Enable
Baud rate generator divisor (DLL, DLM and DLD) enable.
• Logic 0 = Data registers are selected (default).
• Logic 1 = Divisor latch registers are selected.
4.7
Modem Control Register (MCR) or General Purpose Outputs Control - Read/Write
The MCR register is used for controlling the serial/modem interface signals or general purpose inputs/outputs.
30
PRELIMINARY
P1.0.0
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
MCR[0]: DTR# Output
The DTR# pin is a modem control output. If the modem interface is not used, this output may be used as a
general purpose output.
• Logic 0 = Force DTR# output HIGH (default).
• Logic 1 = Force DTR# output LOW.
MCR[1]: RTS# Output
The RTS# pin is a modem control output and may be used for automatic hardware flow control by enabled by
EFR bit-6. The RTS# pin can also be used for Auto RS485 Half-Duplex direction control enabled by FCTR bit3. If the modem interface is not used, this output may be used as a general purpose output.
• Logic 0 = Force RTS# HIGH (default).
• Logic 1 = Force RTS# LOW.
MCR[2]: Reserved
OP1# is not available as an output pin on the M2751. But it is available for use during Internal Loopback Mode.
In the Loopback Mode, this bit is used to write the state of the modem RI# interface signal.
MCR[3]: OP2# Output / INT Output Enable
This bit enables or disables the operation of INT, interrupt output. If INT output is not used, OP2# can be used
as a general purpose output. Also, if 16/68# pin selects Motorola bus interface mode, this bit must be set to
logic 0.
• Logic 0 = INT (A-B) outputs disabled (three state mode) and OP2# output set HIGH(default).
• Logic 1 = INT (A-B) outputs enabled (active mode) and OP2# output set LOW.
MCR[4]: Internal Loopback Enable
• Logic 0 = Disable loopback mode (default).
• Logic 1 = Enable local loopback mode, see loopback section and Figure 12.
MCR[5]: Xon-Any Enable
• Logic 0 = Disable Xon-Any function (default).
• Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation.
The RX character will be loaded into the RX FIFO, unless the RX character is an Xon or Xoff character and
the M2751 is programmed to use the Xon/Xoff flow control.
MCR[6]: Infrared Encoder/Decoder Enable
• Logic 0 = Enable the standard modem receive and transmit input/output interface (default).
• Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the
infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface
requirement. While in this mode, the infrared TX output will be idling LOW. SEE”INFRARED MODE” ON
PAGE 19.
MCR[7]: Clock Prescaler Select
• Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable
Baud Rate Generator without further modification, i.e., divide by one (default).
• Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and
feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth.
31
XR16M2751
PRELIMINARY
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
4.8
P1.0.0
Line Status Register (LSR) - Read Only
This register provides the status of data transfers between the UART and the host.
LSR[0]: Receive Data Ready Indicator
• Logic 0 = No data in receive holding register or FIFO (default).
• Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
LSR[1]: Receiver Overrun Error Flag
• Logic 0 = No overrun error (default).
• Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register
is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into
the FIFO, therefore the data in the FIFO is not corrupted by the error.
LSR[2]: Receive Data Parity Error Tag
• Logic 0 = No parity error (default).
• Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
LSR[3]: Receive Data Framing Error Tag
• Logic 0 = No framing error (default).
• Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
LSR[4]: Receive Break Error Tag
• Logic 0 = No break condition (default).
• Logic 1 = The receiver received a break signal (RX was LOW for at least one character frame time). In the
FIFO mode, only one break character is loaded into the FIFO.
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte
is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0
concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set
when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte.
LSR[6]: THR and TSR Empty Flag
This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or
TSR contains a data character. In the FIFO mode this bit is set to a logic 1 whenever the transmit FIFO and
transmit shift register are both empty.
LSR[7]: Receive FIFO Data Error Flag
• Logic 0 = No FIFO error (default).
• Logic 1 = A global indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error
or break indication is in the FIFO data. This bit clears when there is no more error(s) in any of the bytes in the
RX FIFO.
4.9
Modem Status Register (MSR) - Read Only
This register provides the current state of the modem interface input signals. Lower four bits of this register are
used to indicate the changed information. These bits are set to a logic 1 whenever a signal from the modem
changes state. These bits may be used for general purpose inputs when they are not used with modem
signals.
32
PRELIMINARY
P1.0.0
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
MSR[0]: Delta CTS# Input Flag
• Logic 0 = No change on CTS# input (default).
• Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
MSR[1]: Delta DSR# Input Flag
• Logic 0 = No change on DSR# input (default).
• Logic 1 = The DSR# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
MSR[2]: Delta RI# Input Flag
• Logic 0 = No change on RI# input (default).
• Logic 1 = The RI# input has changed from a LOW to HIGH, ending of the ringing signal. A modem status
interrupt will be generated if MSR interrupt is enabled (IER bit-3).
MSR[3]: Delta CD# Input Flag
• Logic 0 = No change on CD# input (default).
• Logic 1 = Indicates that the CD# input has changed state since the last time it was monitored. A modem
status interrupt will be generated if MSR interrupt is enabled (IER bit-3).
MSR[4]: CTS Input Status
CTS# pin may function as automatic hardware flow control signal input if it is enabled and selected by Auto
CTS (EFR bit-7). Auto CTS flow control allows starting and stopping of local data transmissions based on the
modem CTS# signal. A HIGH on the CTS# pin will stop UART transmitter as soon as the current character has
finished transmission, and a LOW will resume data transmission. Normally MSR bit-4 bit is the complement of
the CTS# input. However in the loopback mode, this bit is equivalent to the RTS# bit in the MCR register. The
CTS# input may be used as a general purpose input when the modem interface is not used.
MSR[5]: DSR Input Status
Normally this bit is the complement of the DSR# input. In the loopback mode, this bit is equivalent to the DTR#
bit in the MCR register. The DSR# input may be used as a general purpose input when the modem interface is
not used.
MSR[6]: RI Input Status
Normally this bit is the complement of the RI# input. In the loopback mode this bit is equivalent to bit-2 in the
MCR register. The RI# input may be used as a general purpose input when the modem interface is not used.
MSR[7]: CD Input Status
Normally this bit is the complement of the CD# input. In the loopback mode this bit is equivalent to bit-3 in the
MCR register. The CD# input may be used as a general purpose input when the modem interface is not used.
4.10
Scratch Pad Register (SPR) - Read/Write
This is a 8-bit general purpose register for the user to store temporary data. The content of this register is
preserved during sleep mode but becomes 0xFF (default) after a reset or a power off-on cycle.
4.11
Enhanced Mode Select Register (EMSR)
This register replaces SPR (during a Write) and is accessible only when FCTR[6] = 1.
33
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
EMSR[1:0]: Receive/Transmit FIFO Level Count (Write-Only)
When Scratchpad Swap (FCTR[6]) is asserted, EMSR bits 1-0 controls what mode the FIFO Level Counter is
operating in.
TABLE 13: SCRATCHPAD SWAP SELECTION
FCTR[6] EMSR[1]
EMSR[0] Scratchpad is
0
X
X
Scratchpad
1
X
0
RX FIFO Level Counter Mode
1
0
1
TX FIFO Level Counter Mode
1
1
1
Alternate RX/TX FIFO Counter Mode
During Alternate RX/TX FIFO Level Counter Mode, the first value read after EMSR bits 1-0 have been
asserted will always be the RX FIFO Level Counter. The second value read will correspond with the TX FIFO
Level Counter. The next value will be the RX FIFO Level Counter again, then the TX FIFO Level Counter and
so on and so forth.
EMSR[2]: Reserved
EMSR[3]: Automatic RS485 Half-Duplex Control Output Inversion
• Logic 0 = RTS# output is LOW during TX and HIGH during RX (default, compatible with 16C2850).
• Logic 1 = RTS# output is HIGH during TX and LOW during RX.
EMSR[5:4]: Extended RTS Hysteresis
TABLE 14: AUTO RTS HYSTERESIS
EMSR
BIT-5
EMSR
BIT-4
FCTR
BIT-1
FCTR
BIT-0
RTS#
HYSTERESIS
(CHARACTERS)
0
0
0
0
0
0
0
0
0
0
1
1
0
1
0
1
0
±4
±6
±8
0
0
0
0
1
1
1
1
0
0
1
1
0
1
0
1
±8
±16
±24
±32
1
1
1
1
0
0
0
0
0
0
1
1
0
1
0
1
±40
±44
±48
±52
1
1
1
1
1
1
1
1
0
0
1
1
0
1
0
1
±12
±20
±28
±36
34
PRELIMINARY
P1.0.0
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
EMSR[6]: LSR Interrupt Mode
• Logic 0 = LSR Interrupt Delayed (for 16C2550 compatibility, default). LSR bits 2, 3, and 4 will generate an
interrupt when the character with the error is in the RHR.
• Logic 1 = LSR Interrupt Immediate. LSR bits 2, 3, and 4 will generate an interrupt as soon as the character is
received into the FIFO.
EMSR[7]: 16X Sampling Rate Mode
Logic 0 = 8X Sampling Rate.
Logic 1 = 16X Sampling Rate (default).
4.12
FIFO Level Register (FLVL) - Read-Only
The FIFO Level Register replaces the Scratchpad Register (during a Read) when FCTR[6] = 1. Note that this is
not identical to the FIFO Data Count Register which can be accessed when LCR = 0xBF.
FLVL[7:0]: FIFO Level Register
This register provides the FIFO counter level for the RX FIFO or the TX FIFO or both depending on EMSR[1:0].
See Table 13 for details.
4.13
Baud Rate Generator Registers (DLL, DLM and DLD) - Read/Write
These registers make-up the value of the baud rate divisor. The concatenation of the contents of DLM and
DLL is a 16-bit value is then added to DLD/16 to achieve the fractional baud rate divisor. DLD must be enabled
via EFR bit-4 before it can be accessed. SEE”PROGRAMMABLE BAUD RATE GENERATOR WITH
FRACTIONAL DIVISOR” ON PAGE 11.
4.14
Device Identification Register (DVID) - Read Only
This register contains the device ID (0x0A for XR16M2751). Prior to reading this register, DLL and DLM should
be set to 0x00 (DLD = 0xXX).
4.15
Device Revision Register (DREV) - Read Only
This register contains the device revision information. For example, 0x01 means revision A. Prior to reading
this register, DLL and DLM should be set to 0x00 (DLD = 0xXX).
4.16
Trigger Level Register (TRG) - Write-Only
User Programmable Transmit/Receive Trigger Level Register. If both the TX and RX trigger levels are used,
the TX trigger levels must be set before the RX trigger levels.
TRG[7:0]: Trigger Level Register
These bits are used to program desired trigger levels when trigger Table-D is selected. FCTR bit-7 selects
between programming the RX Trigger Level (a logic 0) and the TX Trigger Level (a logic 1).
4.17
RX/TX FIFO Level Count Register (FC) - Read-Only
This register is accessible when LCR = 0xBF. Note that this register is not identical to the FIFO Level Count
Register which is located in the general register set when FCTR bit-6 = 1 (Scratchpad Register Swap). It is
suggested to read the FIFO Level Count Register at the Scratchpad Register location when FCTR bit-6 = 1.
See Table 13.
FC[7:0]: RX/TX FIFO Level Count
Receive/Transmit FIFO Level Count. Number of characters in Receiver FIFO (FCTR[7] = 0) or Transmitter
FIFO (FCTR[7] = 1) can be read via this register. Reading this register is not recommended when transmitting
or receiving data.
4.18
Feature Control Register (FCTR) - Read/Write
This register controls the XR16M2751 new functions that are not available in ST16C2450 or ST16C2550.
FCTR[1:0]: RTS Hysteresis
User selectable RTS# hysteresis levels for hardware flow control application. After reset, these bits are set to
“0” to select the next trigger level for hardware flow control. See Table 14 for more details.
35
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
FCTR[2]: IrDa RX Inversion
• Logic 0 = Select RX input as encoded IrDa data (Idle state will be LOW).
• Logic 1 = Select RX input as inverted encoded IrDa data (Idle state will be HIGH).
FCTR[3]: Auto RS-485 Direction Control
• Logic 0 = Standard ST16C550 mode. Transmitter generates an interrupt when transmit holding register
becomes empty and transmit shift register is shifting data out.
• Logic 1 = Enable Auto RS485 Direction Control function. The direction control signal, RTS# pin, changes its
output logic state from LOW to HIGH one bit time after the last stop bit of the last character is shifted out.
Also, the Transmit interrupt generation is delayed until the transmitter shift register becomes empty. The
RTS# output pin will automatically return to a LOW when a data byte is loaded into the TX FIFO. However,
RTS# behavior can be inverted by setting EMSR[3] = 1.
FCTR[5:4]: Transmit/Receive Trigger Table Select
See Table 11 for more details.
TABLE 15: TRIGGER TABLE SELECT
FCTR
BIT-5
FCTR
BIT-4
0
0
Table-A (TX/RX)
0
1
Table-B (TX/RX)
1
0
Table-C (TX/RX)
1
1
Table-D (TX/RX)
TABLE
FCTR[6]: Scratchpad Swap
• Logic 0 = Scratch Pad register is selected as general read and write register. ST16C550 compatible mode.
• Logic 1 = FIFO Level Count register (Read-Only), Enhanced Mode Select Register (Write-Only). Number of
characters in transmit or receive FIFO can be read via scratch pad register when this bit is set. Enhanced
Mode Select Register is selected when it is written into.
FCTR[7]: Programmable Trigger Register Select
If using both programmable TX and RX trigger levels, TX trigger levels must be set before RX trigger levels.
• Logic 0 = Registers TRG and FC selected for RX.
• Logic 1 = Registers TRG and FC selected for TX.
4.19
Enhanced Feature Register (EFR)
Enhanced features are enabled or disabled using this register. Bit 0-3 provide single or dual consecutive
character software flow control selection (see Table 16). When the Xon1 and Xon2 and Xoff1 and Xoff2 modes
are selected, the double 8-bit words are concatenated into two sequential characters. Caution: note that
whenever changing the TX or RX flow control bits, always reset all bits back to logic 0 (disable) before
programming a new setting.
EFR[3:0]: Software Flow Control Select
Single character and dual sequential characters software flow control is supported. Combinations of software
flow control can be selected by programming these bits.
36
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
TABLE 16: SOFTWARE FLOW CONTROL FUNCTIONS
EFR BIT-3
CONT-3
EFR BIT-2
CONT-2
EFR BIT-1
CONT-1
EFR BIT-0
CONT-0
0
0
0
0
No TX and RX flow control (default and reset)
0
0
X
X
No transmit flow control
1
0
X
X
Transmit Xon1, Xoff1
0
1
X
X
Transmit Xon2, Xoff2
1
1
X
X
Transmit Xon1 and Xon2, Xoff1 and Xoff2
X
X
0
0
No receive flow control
X
X
1
0
Receiver compares Xon1, Xoff1
X
X
0
1
Receiver compares Xon2, Xoff2
1
0
1
1
Transmit Xon1, Xoff1
Receiver compares Xon1 or Xon2, Xoff1 or Xoff2
0
1
1
1
Transmit Xon2, Xoff2
Receiver compares Xon1 or Xon2, Xoff1 or Xoff2
1
1
1
1
Transmit Xon1 and Xon2, Xoff1 and Xoff2,
Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
0
0
1
1
No transmit flow control,
Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
TRANSMIT AND RECEIVE SOFTWARE FLOW CONTROL
EFR[4]: Enhanced Function Bits Enable
Enhanced function control bit. This bit enables IER bits 4-7, ISR bits 4-5, FCR bits 4-5, MCR bits 5-7, and DLD
to be modified. After modifying any enhanced bits, EFR bit-4 can be set to a logic 0 to latch the new values.
This feature prevents legacy software from altering or overwriting the enhanced functions once set. Normally, it
is recommended to leave it enabled, logic 1.
• Logic 0 = modification disable/latch enhanced features. IER bits 4-7, ISR bits 4-5, FCR bits 4-5, MCR bits 57, and DLD are saved to retain the user settings. After a reset, the IER bits 4-7, ISR bits 4-5, FCR bits 4-5,
MCR bits 5-7, and DLD are set to a logic 0 to be compatible with ST16C550 mode (default).
• Logic 1 = Enables the above-mentioned register bits to be modified by the user.
EFR[5]: Special Character Detect Enable
• Logic 0 = Special Character Detect Disabled (default).
• Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with
data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set
to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If
flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= ‘10’) then flow control and special character work
normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= ‘01’) then flow control works
normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character
interrupt, if enabled via IER bit-5.
37
XR16M2751
PRELIMINARY
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
EFR[6]: Auto RTS Flow Control Enable
RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is
selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and
RTS de-asserts HIGH at the next upper trigger level or hysteresis level. RTS# will return LOW when FIFO data
falls below the next lower trigger level. The RTS# output must be asserted (LOW) before the auto RTS can
take effect. RTS# pin will function as a general purpose output when hardware flow control is disabled.
• Logic 0 = Automatic RTS flow control is disabled (default).
• Logic 1 = Enable Automatic RTS flow control.
EFR[7]: Auto CTS Flow Control Enable
Automatic CTS Flow Control.
• Logic 0 = Automatic CTS flow control is disabled (default).
• Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts HIGH.
Data transmission resumes when CTS# returns LOW.
4.19.1
Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write
These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2.
For more details, see Table 7.
38
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
TABLE 17: UART RESET CONDITIONS FOR CHANNEL A AND B
REGISTERS
RESET STATE
DLM, DLL
DLM = 0x00 and DLL = 0x01. Only resets to these values during a power up.
They do not reset when the Reset Pin is asserted.
DLD
Bits 7-0 = 0x00
RHR
Bits 7-0 = 0xXX
THR
Bits 7-0 = 0xXX
IER
Bits 7-0 = 0x00
FCR
Bits 7-0 = 0x00
ISR
Bits 7-0 = 0x01
LCR
Bits 7-0 = 0x00
MCR
Bits 7-0 = 0x00
LSR
Bits 7-0 = 0x60
MSR
Bits 3-0 = Logic 0
Bits 7-4 = Logic levels of the inputs inverted
SPR
Bits 7-0 = 0xFF
EMSR
Bits 7-0 = 0x80
FLVL
Bits 7-0 = 0x00
EFR
Bits 7-0 = 0x00
XON1
Bits 7-0 = 0x00
XON2
Bits 7-0 = 0x00
XOFF1
Bits 7-0 = 0x00
XOFF2
Bits 7-0 = 0x00
FC
Bits 7-0 = 0x00
I/O SIGNALS
RESET STATE
TX
HIGH
OP2#
HIGH
RTS#
HIGH
DTR#
HIGH
RXRDY#
HIGH
TXRDY#
LOW
INT
(IRQ#)
Three-State Condition (16 mode)
HIGH (68 mode)
39
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
ABSOLUTE MAXIMUM RATINGS
Power Supply Range
7 Volts
Voltage at Any Pin
GND-0.3V to 7V
Operating Temperature
-40o to +85oC
Storage Temperature
-65o to +150oC
Package Dissipation
500 mW
TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: ± 15%)
Thermal Resistance (48-TQFP)
theta-ja =59oC/W, theta-jc = 16oC/W
ELECTRICAL CHARACTERISTICS
DC ELECTRICAL CHARACTERISTICS
TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC IS 1.62V TO 3.6V
SYMBOL
PARAMETER
LIMITS
1.8V
MIN
MAX
LIMITS
2.5V
MIN
MAX
LIMITS
3.3V
MIN
MAX
UNITS
CONDITIONS
VILCK
Clock Input Low Level
-0.3
0.3
-0.3
0.4
-0.3
0.6
V
VIHCK
Clock Input High Level
1.4
VCC
2.0
VCC
2.4
VCC
V
VIL
Input Low Voltage
-0.3
0.2
-0.3
0.5
-0.3
0.7
V
VIH
Input High Voltage
1.4
VCC
1.8
VCC
2.0
VCC
V
VOL
Output Low Voltage
0.4
V
V
V
IOL = 4 mA
V
V
V
IOH = -1 mA
0.4
0.4
VOH
Output High Voltage
2.0
1.8
1.4
IIL
Input Low Leakage Current
±10
±10
±10
uA
IIH
Input High Leakage Current
±10
±10
±10
uA
CIN
Input Pin Capacitance
5
5
5
pF
ICC
Power Supply Current
0.5
1.5
2.5
mA
5
15
30
uA
ISLEEP
Sleep Current
IOL = 2 mA
IOL = 1.5 mA
IOH = -400 uA
IOH = -200 uA
See Test 1
Test 1: The following inputs must remain steady at VCC or GND state to minimize sleep current: A0-A2, D0-D7,
IOR#, IOW# (R/W#), CSA# (CS#), CSB# (A3) and all modem inputs. Also, RXA and RXB inputs must idle
HIGH while asleep. Floating inputs may result in sleep currents in the mA range.
40
PRELIMINARY
P1.0.0
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
For PowerSave, the UART internally isolates all of these inputs (except the modem inputs) therefore
eliminating any unnecessary external buffers to keep the inputs steady. SEE”POWERSAVE FEATURE” ON
PAGE 20.
AC ELECTRICAL CHARACTERISTICS
UNLESS OTHERWISE NOTED: TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC=1.62 3.63V, 70 PF LOAD WHERE APPLICABLE
SYMBOL
PARAMETER
LIMITS
1.8V ± 10%
MIN
MAX
LIMITS
2.5V ± 10%
MIN
MAX
LIMITS
3.3V ± 10%
MIN
MAX
UNIT
XTAL1
UART Crystal Oscillator
24
32
24
MHz
ECLK
External Clock
32
50
64
MHz
TECLK
External Clock Time Period
15
10
7
ns
TAS
Address Setup Time (16 mode)
0
0
0
ns
TAH
Address Hold Time (16 mode)
0
0
0
ns
TCS
Chip Select Width (16 mode)
65
50
40
ns
TRD
IOR# Strobe Width (16 mode)
65
50
40
ns
TDY
Read Cycle Delay (16 mode)
65
50
40
ns
TRDV
Data Access Time (16 mode)
60
45
35
ns
TDD
Data Disable Time (16 mode)
25
25
25
ns
TWR
IOW# Strobe Width (16 mode)
65
50
40
ns
TDY
Write Cycle Delay (16 mode)
65
50
40
ns
TDS
Data Setup Time (16 mode)
20
10
10
ns
TDH
Data Hold Time (16 mode)
5
5
5
ns
TADS
Address Setup (68 Mode)
0
0
0
ns
TADH
Address Hold (68 Mode)
0
0
0
ns
TRWS
R/W# Setup to CS# (68 Mode)
0
0
0
ns
TRDA
Read Data Access (68 mode)
60
45
35
ns
TRDH
Read Data Disable (68 mode)
25
25
25
ns
TWDS
Write Data Setup (68 mode)
20
10
10
ns
TWDH
Write Data Hold (68 Mode)
5
5
5
ns
TRWH
CS# De-asserted to R/W# De-asserted (68
Mode)
5
5
5
ns
TCSL
CS# Width (68 Mode)
65
50
40
ns
TCSD
CS# Cycle Delay (68 Mode)
65
50
40
ns
TWDO
Delay From IOW# To Output
50
50
50
ns
TMOD
Delay To Set Interrupt From MODEM Input
50
50
50
ns
41
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
AC ELECTRICAL CHARACTERISTICS
UNLESS OTHERWISE NOTED: TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC=1.62 3.63V, 70 PF LOAD WHERE APPLICABLE
SYMBOL
LIMITS
1.8V ± 10%
MIN
MAX
PARAMETER
LIMITS
2.5V ± 10%
MIN
MAX
LIMITS
3.3V ± 10%
MIN
MAX
UNIT
TRSI
Delay To Reset Interrupt From IOR#
50
50
50
ns
TSSI
Delay From Stop To Set Interrupt
1
1
1
Bclk
TRRI
Delay From IOR# To Reset Interrupt
45
45
45
ns
TSI
Delay From Stop To Interrupt
45
45
45
ns
TINT
Delay From Initial INT Reset To Transmit Start
24
Bclk
TWRI
Delay From IOW# To Reset Interrupt
45
45
45
ns
TSSR
Delay From Stop To Set RXRDY#
1
1
1
Bclk
TRR
Delay From IOR# To Reset RXRDY#
45
45
45
ns
TWT
Delay From IOW# To Set TXRDY#
45
45
45
ns
TSRT
Delay From Center of Start To Reset TXRDY#
8
8
8
Bclk
TRST
Reset Pulse Width
Bclk
Baud Clock
8
40
24
8
24
40
40
16X or 8X of data rate
FIGURE 13. CLOCK TIMING
TECLK
TECL
TECH
VIH
External
Clock
VIL
42
8
ns
Hz
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
FIGURE 14. MODEM INPUT/OUTPUT TIMING FOR CHANNELS A & B
IOW #
Active
T W DO
RTS#
DTR#
Change of state
Change of state
CD#
CTS#
DSR#
Change of state
Change of state
T MO D
T M OD
INT
Active
Active
Active
T RSI
IOR#
Active
Active
Active
T M OD
Change of state
RI#
FIGURE 15. 16 MODE (INTEL) DATA BUS READ TIMING
A0-A2
Valid Address
TAS
TCS
Valid Address
TAS
TAH
TAH
TCS
CSA#/
CSB#
TDY
TRD
TRD
IOR#
TDD
TRDV
D0-D7
Valid Data
TDD
TRDV
Valid Data
RDTm
43
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
FIGURE 16. 16 MODE (INTEL) DATA BUS WRITE TIMING
A0-A2
Valid Address
Valid Address
TAS
TAS
TAH
TCS
TAH
TCS
CSA#/
CSB#
TDY
TWR
TWR
IOW#
TDH
TDS
Valid Data
D0-D7
TDH
TDS
Valid Data
16Write
FIGURE 17. 68 MODE (MOTOROLA) DATA BUS READ TIMING
A0-A2
Valid Address
TADS
TCSL
Valid Address
TADH
CS#
TCSD
TRWS
TRWH
R/W#
TRDH
TRDA
D0-D7
Valid Data
Valid Data
68Read
44
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
FIGURE 18. 68 MODE (MOTOROLA) DATA BUS WRITE TIMING
A0-A2
Valid Address
TADS
TCSL
Valid Address
TADH
CS#
TCSD
TRWS
TRWH
R/W#
TWDS
D0-D7
T WDH
Valid Data
Valid Data
68Write
FIGURE 19. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B
RX
INT
RXRDY#
Start
Bit
D0:D7
Stop
Bit
D0:D7
D0:D7
TSSR
TSSR
TSSR
1 Byte
in RHR
1 Byte
in RHR
1 Byte
in RHR
TSSR
TSSR
Active
Data
Ready
Active
Data
Ready
TRR
TRR
TSSR
Active
Data
Ready
TRR
IOR#
(Reading data
out of RHR)
RXNFM
45
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
FIGURE 20. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B
TX
Start
Bit
IER[1]
enabled
Stop
Bit
D0:D7
D0:D7
ISR is read
D0:D7
ISR is read
ISR is read
INT*
TWRI
TWRI
TWRI
TSRT
TSRT
TSRT
TXRDY#
TWT
TWT
TWT
IOW#
(Loading data
into THR)
*INT is cleared when the ISR is read or when data is loaded into the THR.
TXNonFIFO
FIGURE 21. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA DISABLED] FOR CHANNELS A & B
Start
Bit
RX
S D0:D7
S D0:D7 T
Stop
Bit
D0:D7
S D0:D7 T
S D0:D7 T S D0:D7 T
S D0:D7 T
RX FIFO drops
below RX
Trigger Level
TSSI
INT
FIFO
Empties
TSSR
RX FIFO fills up to RX
Trigger Level or RX Data
Timeout
RXRDY#
First Byte is
Received in
RX FIFO
TRRI
TRR
IOR#
(Reading data out
of RX FIFO)
RXINTDMA#
46
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
FIGURE 22. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA ENABLED] FOR CHANNELS A & B
Start
Bit
RX
Stop
Bit
S D0:D7
S D0:D7 T
D0:D7
S D0:D7 T
S D0:D7 T S D0:D7 T
S D0:D7 T
RX FIFO drops
below RX
Trigger Level
TSSI
INT
RX FIFO fills up to RX
Trigger Level or RX Data
Timeout
FIFO
Empties
TSSR
RXRDY#
TRRI
TRR
IOR#
(Reading data out
of RX FIFO)
RXFIFODMA
FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE DISABLED] FOR CHANNELS A & B
TX FIFO
Empty
TX
Start
Bit
Stop
Bit
S D0:D7 T
(Unloading)
IER[1]
enabled
Last Data Byte
Transmitted
T S D0:D7 T S D0:D7 T
S D0:D7 T S D0:D7 T
TSI
ISR is read
S D0:D7 T
ISR is read
TSRT
INT*
TX FIFO fills up
to trigger level
TXRDY#
Data in
TX FIFO
TX FIFO
Empty
TWRI
TX FIFO drops
below trigger level
TWT
IOW#
(Loading data
into FIFO)
*INT is cleared when the ISR is read or when TX FIFO fills up to the trigger level.
47
TXDMA#
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
FIGURE 24. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE ENABLED] FOR CHANNELS A & B
Start
Bit
TX
Stop
Bit
Last Data Byte
Transmitted
S D0:D7 T S D0:D7 T
(Unloading)
IER[1]
enabled
D0:D7
S D0:D7 T
ISR Read
S D0:D7 T S D0:D7 T
S D0:D7 T
TSI
TSRT
ISR Read
INT*
TX FIFO fills up
to trigger level
TXRDY#
TX FIFO drops
below trigger level
TWRI
At least 1
empty location
in FIFO
TX FIFO
Full
TWT
IOW#
(Loading data
into FIFO)
*INT cleared when the ISR is read or when TX FIFO fills up to trigger level.
48
TXDMA
PRELIMINARY
P1.0.0
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
PACKAGE DIMENSIONS (48 PIN TQFP - 7 X 7 X 1 mm)
D
D1
36
25
37
24
D1
48
13
1
2
1
B
e
A2
C
A
α
Seating
Plane
A1
L
Note: The control dimension is the millimeter column
INCHES
MILLIMETERS
SYMBOL
MIN
MAX
MIN
MAX
A
0.039
0.047
1.00
1.20
A1
0.002
0.006
0.05
0.15
A2
0.037
0.041
0.95
1.05
B
0.007
0.011
0.17
0.27
C
0.004
0.008
0.09
0.20
D
0.346
0.362
8.80
9.20
D1
0.272
0.280
6.90
7.10
e
0.020 BSC
0.50 BSC
L
0.018
0.030
0.45
0.75
a
0°
7°
0°
7°
49
D
PRELIMINARY
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
REVISION HISTORY
DATE
REVISION
June 2007
P1.0.0
DESCRIPTION
Preliminary Datasheet.
NOTICE
EXAR Corporation reserves the right to make changes to the products contained in this publication in order to
improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any
circuits described herein, conveys no license under any patent or other right, and makes no representation that
the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration
purposes and may vary depending upon a user’s specific application. While the information in this publication
has been carefully checked; no responsibility, however, is assumed for inaccuracies.
EXAR Corporation does not recommend the use of any of its products in life support applications where the
failure or malfunction of the product can reasonably be expected to cause failure of the life support system or
to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless
EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has
been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately
protected under the circumstances.
Copyright 2007 EXAR Corporation
Datasheet June 2007.
Send your UART technical inquiry with technical details to hotline: [email protected].
Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited.
50
XR16M2751
REV. P1.0.0
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
TABLE OF CONTENTS
GENERAL DESCRIPTION................................................................................................ 1
APPLICATIONS .............................................................................................................................................. 1
FEATURES .................................................................................................................................................... 1
FIGURE 1. XR16M2751 BLOCK DIAGRAM ........................................................................................................................................ 1
FIGURE 2. PIN OUT ASSIGNMENT ..................................................................................................................................................... 2
ORDERING INFORMATION ............................................................................................................................... 2
PIN DESCRIPTIONS ........................................................................................................ 3
1.0 PRODUCT DESCRIPTION ...................................................................................................................... 7
2.0 FUNCTIONAL DESCRIPTIONS .............................................................................................................. 8
2.1 CPU INTERFACE ................................................................................................................................................ 8
FIGURE 3. XR16M2751 TYPICAL INTEL/MOTOROLA DATA BUS INTERCONNECTIONS .......................................................................... 8
2.2 DEVICE RESET ................................................................................................................................................... 8
2.3 DEVICE IDENTIFICATION AND REVISION ....................................................................................................... 9
2.4 CHANNEL A AND B SELECTION ...................................................................................................................... 9
TABLE 1: CHANNEL A AND B SELECT IN 16 MODE ............................................................................................................................ 9
TABLE 2: CHANNEL A AND B SELECT IN 68 MODE ............................................................................................................................ 9
2.5 CHANNEL A AND B INTERNAL REGISTERS ................................................................................................... 9
2.6 DMA MODE ......................................................................................................................................................... 9
TABLE 3: TXRDY# AND RXRDY# OUTPUTS IN FIFO AND DMA MODE ........................................................................................... 10
2.7 INTA AND INTB OUTPUTS............................................................................................................................... 10
TABLE 4: INTA AND INTB PINS OPERATION FOR TRANSMITTER ...................................................................................................... 10
TABLE 5: INTA AND INTB PIN OPERATION FOR RECEIVER ............................................................................................................. 10
2.8 CRYSTAL OSCILLATOR OR EXTERNAL CLOCK INPUT.............................................................................. 11
FIGURE 4. TYPICAL OSCILLATOR CONNECTIONS............................................................................................................................... 11
2.9 PROGRAMMABLE BAUD RATE GENERATOR WITH FRACTIONAL DIVISOR ........................................... 11
FIGURE 5. BAUD RATE GENERATOR ............................................................................................................................................... 12
TABLE 6: TYPICAL DATA RATES WITH A 24 MHZ CRYSTAL OR EXTERNAL CLOCK AT 16X SAMPLING ................................................... 13
2.10 TRANSMITTER................................................................................................................................................ 13
2.10.1 TRANSMIT HOLDING REGISTER (THR) - WRITE ONLY.........................................................................................
2.10.2 TRANSMITTER OPERATION IN NON-FIFO MODE ..................................................................................................
FIGURE 6. TRANSMITTER OPERATION IN NON-FIFO MODE ..............................................................................................................
2.10.3 TRANSMITTER OPERATION IN FIFO MODE ...........................................................................................................
FIGURE 7. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE .....................................................................................
14
14
14
14
14
2.11 RECEIVER ....................................................................................................................................................... 15
2.11.1 RECEIVE HOLDING REGISTER (RHR) - READ-ONLY ............................................................................................ 15
FIGURE 8. RECEIVER OPERATION IN NON-FIFO MODE .................................................................................................................... 15
FIGURE 9. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE ......................................................................... 16
2.12 AUTO RTS (HARDWARE) FLOW CONTROL ................................................................................................ 16
2.13 AUTO RTS HYSTERESIS .............................................................................................................................. 16
2.14 AUTO CTS FLOW CONTROL........................................................................................................................ 17
FIGURE 10. AUTO RTS AND CTS FLOW CONTROL OPERATION ....................................................................................................... 17
2.15 AUTO XON/XOFF (SOFTWARE) FLOW CONTROL...................................................................................... 18
TABLE 7: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL ............................................................................................................... 18
2.16 SPECIAL CHARACTER DETECT.................................................................................................................. 18
2.17 AUTO RS485 HALF-DUPLEX CONTROL ..................................................................................................... 18
2.18 INFRARED MODE ........................................................................................................................................... 19
FIGURE 11. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING .......................................................................... 19
2.19 SLEEP MODE WITH WAKE-UP INDICATOR AND POWERSAVE FEATURE ............................................ 20
2.19.1 SLEEP MODE ............................................................................................................................................................. 20
2.19.2 POWERSAVE FEATURE............................................................................................................................................ 20
2.20 INTERNAL LOOPBACK................................................................................................................................. 21
FIGURE 12. INTERNAL LOOP BACK IN CHANNEL A AND B ................................................................................................................ 21
3.0 UART INTERNAL REGISTERS............................................................................................................. 22
TABLE 8: UART CHANNEL A AND B UART INTERNAL REGISTERS ...................................................................................... 22
TABLE 9: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1 ......................................... 23
4.0 INTERNAL REGISTER DESCRIPTIONS .............................................................................................. 24
4.1 RECEIVE HOLDING REGISTER (RHR) - READ- ONLY .................................................................................. 24
4.2 TRANSMIT HOLDING REGISTER (THR) - WRITE-ONLY ............................................................................... 24
4.3 INTERRUPT ENABLE REGISTER (IER) - READ/WRITE ................................................................................ 24
I
XR16M2751
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
REV. P1.0.0
4.3.1 IER VERSUS RECEIVE FIFO INTERRUPT MODE OPERATION ............................................................................... 25
4.3.2 IER VERSUS RECEIVE/TRANSMIT FIFO POLLED MODE OPERATION .................................................................. 25
4.4 INTERRUPT STATUS REGISTER (ISR) - READ-ONLY .................................................................................. 26
4.4.1 INTERRUPT GENERATION: ........................................................................................................................................ 26
4.4.2 INTERRUPT CLEARING: ............................................................................................................................................. 26
TABLE 10: INTERRUPT SOURCE AND PRIORITY LEVEL ..................................................................................................................... 27
4.5 FIFO CONTROL REGISTER (FCR) - WRITE-ONLY......................................................................................... 27
TABLE 11: TRANSMIT AND RECEIVE FIFO TRIGGER TABLE AND LEVEL SELECTION .......................................................................... 28
4.6 LINE CONTROL REGISTER (LCR) - READ/WRITE......................................................................................... 29
TABLE 12: PARITY SELECTION ........................................................................................................................................................ 30
4.7 MODEM CONTROL REGISTER (MCR) OR GENERAL PURPOSE OUTPUTS CONTROL - READ/WRITE..
4.8 LINE STATUS REGISTER (LSR) - READ ONLY..............................................................................................
4.9 MODEM STATUS REGISTER (MSR) - READ ONLY .......................................................................................
4.10 SCRATCH PAD REGISTER (SPR) - READ/WRITE .......................................................................................
4.11 ENHANCED MODE SELECT REGISTER (EMSR) .........................................................................................
30
32
32
33
33
TABLE 13: SCRATCHPAD SWAP SELECTION .................................................................................................................................... 34
TABLE 14: AUTO RTS HYSTERESIS ................................................................................................................................................ 34
4.12 FIFO LEVEL REGISTER (FLVL) - READ-ONLY.............................................................................................
4.13 BAUD RATE GENERATOR REGISTERS (DLL, DLM AND DLD) - READ/WRITE .......................................
4.14 DEVICE IDENTIFICATION REGISTER (DVID) - READ ONLY.......................................................................
4.15 DEVICE REVISION REGISTER (DREV) - READ ONLY .................................................................................
4.16 TRIGGER LEVEL REGISTER (TRG) - WRITE-ONLY ....................................................................................
4.17 RX/TX FIFO LEVEL COUNT REGISTER (FC) - READ-ONLY .......................................................................
4.18 FEATURE CONTROL REGISTER (FCTR) - READ/WRITE...........................................................................
35
35
35
35
35
35
35
TABLE 15: TRIGGER TABLE SELECT ................................................................................................................................................ 36
4.19 ENHANCED FEATURE REGISTER (EFR) ..................................................................................................... 36
TABLE 16: SOFTWARE FLOW CONTROL FUNCTIONS ........................................................................................................................ 37
4.19.1 SOFTWARE FLOW CONTROL REGISTERS (XOFF1, XOFF2, XON1, XON2) - READ/WRITE .............................. 38
TABLE 17: UART RESET CONDITIONS FOR CHANNEL A AND B ............................................................................................ 39
ABSOLUTE MAXIMUM RATINGS.................................................................................. 40
TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: ± 15%) 40
ELECTRICAL CHARACTERISTICS ............................................................................... 40
DC ELECTRICAL CHARACTERISTICS ............................................................................................................. 40
TA=0o to 70oC (-40o to +85oC for industrial grade package), Vcc is 1.62V to 3.6V ............................................. 40
AC ELECTRICAL CHARACTERISTICS ............................................................................................................. 41
Unless otherwise noted: TA=0o to 70oC (-40o to +85oC for industrial grade package), Vcc=1.62 - 3.63V, 70 pF load
where applicable....................................................................................................................................................... 41
FIGURE 13. CLOCK TIMING ............................................................................................................................................................. 42
FIGURE 14. MODEM INPUT/OUTPUT TIMING FOR CHANNELS A & B ................................................................................................. 43
FIGURE 15. 16 MODE (INTEL) DATA BUS READ TIMING ................................................................................................................... 43
FIGURE 16. 16 MODE (INTEL) DATA BUS WRITE TIMING.................................................................................................................. 44
FIGURE 17. 68 MODE (MOTOROLA) DATA BUS READ TIMING .......................................................................................................... 44
FIGURE 18. 68 MODE (MOTOROLA) DATA BUS WRITE TIMING ......................................................................................................... 45
FIGURE 19. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B ......................................................... 45
FIGURE 20. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B ....................................................... 46
FIGURE 21. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA DISABLED] FOR CHANNELS A & B........................................ 46
FIGURE 22. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA ENABLED] FOR CHANNELS A & B......................................... 47
FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE DISABLED] FOR CHANNELS A & B............................ 47
FIGURE 24. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE ENABLED] FOR CHANNELS A & B ............................ 48
PACKAGE DIMENSIONS (48 PIN TQFP - 7 X 7 X 1 mm)................................................................................... 49
REVISION HISTORY...................................................................................................................................... 50
TABLE OF CONTENTS...................................................................................................... I
II