FCI RL257

RL251 . . . 257 Series
Data Sheet
2.5 Amp MINIATURE
PLASTIC SILICON RECTIFIERS
Description
Mechanical Dimensions
JEDEC
D0-15
.230
.300
1.00 Min.
.104
.140
.031 typ.
Features
n LOW COST
n DIFFUSED JUNCTION
n LOW LEAKAGE
n MEETS UL SPECIFICATION 94V-0
Electrical Characteristics @ 25oC.
RL251 . . . RL257 Series
Maximum Ratings
RL251
RL252
RL253
RL254
Units
RL255
RL256
RL257
Peak Repetitive Reverse Voltage...VRRM
50
100
200
400
600
800
1000
Volts
RMS Reverse Voltage...VR(rms)
35
70
140
280
420
560
700
Volts
DC Blocking Voltage...VDC
50
100
200
400
600
800
1000
Volts
Average Forward Rectified Current...IF(av)
TA = 55°C (Note 3)
............................................. 2.5 ...............................................
Amps
Non-Repetitive Peak Forward Surge Current...IFSM
@ Rated Current & Temp
............................................. 200 ...............................................
Amps
Forward Voltage @ 3.0A...VF
............................................. 1.0 ...............................................
Volts
DC Reverse Current...IR
@ 25°C
@ Rated DC Blocking Voltage @ 75°C
............................................. 1.0 ...............................................
............................................. 100 ...............................................
µAmps
µAmps
Typical Junction Capacitance...CJ (Note 1)
< ....................
Typical Thermal Resistance...RθJC (Note 2)
............................................. 28 ...............................................
°C / W
Operating & Storage Temperature Range...TJ, TSTRG
......................................... -65 to 175 ..........................................
°C
Page 9-10
50
................... > < ............. 25 ............ >
pF
2.5 Amp MINIATURE
PLASTIC SILICON RECTIFIERS
Instantaneous Forward Characteristics
Distribution
Amps
pF
Typical Junction Capacitance
RL251 . . . 257 Series
Data Sheet
TJ = 25°°C
Reverse Voltage (Volts)
Forward Voltage (Volts)
TJ = 175°° C
PW = 8.3ms
Forward Current Derating Curve
Amps
Amps
Peak Forward Surge Current
Ratings at
25 Deg. C ambient
temperature
unless otherwise
specified.
Number of Cycles @ 60 Hz
NOTES: 1. Measured @ 1 MHZ and applied reverse voltage of 4.0V.
2. Thermal Resistance Junction to Ambient, Jedec Method.
3. When Mounted to heat sink, from body.
TA = Ambient Temperature (°°C)
Single Phase Half
Wave, 60 HZ
Resistive or
Inductive Load.
For Capacitive
Load, Derate
Current by 20%.
Page 9-11