FILTRAN 7100

HDSL
Transformer
7100
• Designed for use with Level One’s ICs SK70721/725
and Zarlink’s MH88435 and MH88612
• Excellent THD performance
• Designed to meet the supplementary insulation requirements
of UL 1950, IEC950 and EN60950 for working voltages up to 250Vrms
• Extended temperature range: -40°C to +85°C
MECHANICAL AND SCHEMATIC (All dimensions in inches)
SUGGESTED PAD LAYOUT
SCHEMATIC
1 : 1.8
1 : 1.8
UNLESS OTHERWISE SPECIFIED, ALL TOLERANCES ARE ±0.010
7100
1:1.8
ISSUE: A
Turns
Ratio
(±2%)
08/08/02
ELECTRICAL SPECIFICATION @ 25˚C
Inductance
(mH ± 10%)
Leakage Inductance
(µH MAX)
Line Side
(10-7)(w/ 6-9 shorted)
(10-7)(w/ 6-9, 1-4 , 2-5 shorted)
3.00
30
Longitudinal Balance
(dB MIN @ 135Ω)
DC Resistance
(Ω MAX)
Return Loss
(dB MIN)
5 – 196 kHz
40 – 200 kHz
50
16.5
Line Side
Chip Side
(10-6)=(9-7)
(1-5)(w/ 2-4 shorted)
1.5
2.3
Isolation
Voltage
(Vrms)
• THD Typical @ 135Ω: -75dB @ 5kHz, 6V p-p
229 Colonnade Road, Ottawa, Ontario, Canada K2E 7K3
Tel: (613) 226-1626 Fax: (613) 226-7124 www.filtran.com
An ISO 9001 Registered Company
2000