FILTRAN TEW5614

CEPT
TEW5514 is designed and
approved to be used as a
receive transformer in CEPT
applications, 75 Ω coaxial line,
with the following devices:
Typical applications are:
–
STC
TEW5614
Input Transformer
TEL5219L
•
Primary rate ISDN network
nodes.
•
PBX or computer to CEPT
Digital Trunks.
•
TDM Multiplexers.
Longitudinal Bal.: Exceeds the
requirements of CCITT I.431.
Return Loss: Exceeds the
requirements of
CCITT G.703 and BS6328.
MECHANICAL
5
3
Top view
4
Line
TEL5219L
1
5
6
3
4
1
2
6
2
All dimensions
are in mm.
Recommended
foot print
ISSUE: A
94/11/115614.chp
ELECTRICAL SPECIFICATION
Line Impedance
TEW5614
(5 - 6)
Turns ratio
Inductance (mH)
75 Ω
(1 -2) : (3 - 4) : (5 - 6)
1:1:1
(5 - 6)
> 0.75
Longitud. Bal.
I.431
Return Loss
G.703
Dielectric Strength (Vrms)
1500
Filtran Limited
229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3,
Tel : (613) 226 -1626 Fax : (613) 226 -7124
2-48