GRAYHILL 70RCK4R

System 50
RACKS
4 Channel
FEATURES
• Use for Isolating and Coverting Signal Types to
Standard Logic Voltages
• Terminal Block Connection for Input and Output
• Available for Standard and G5 I/O Modules
• Panel and DIN Rail Mount Versions
• UL, CSA Certified
4 CHANNEL RACK: Standard
Part No. 70RCK4
Dimensions are shown in inches
(and millimeters).
All tolerances are ± 0.010 (0,25)
unless otherwise specified.
STANDOFF I.D. 0.15 ( 3,8),DIA.
(4 PLACES)
CLEARANCE FOR #6 SCREW
9 POSITION TERMINAL
STRIP FOR GROUND
AND LOGIC SIGNALS
MODULE SHOWN FOR
REFERENCE ONLY
9
8
7
6
5
4
3
2
1
AC INPUT
B AC OUTPUT
Y
STATUS LED
3.00
(76,2)
3.3K RESISTOR
9
8
7
6
5
4
3
2
1
DC OUTPUT
5 AMP FUSE
R
W DC INPUT
NOTE: MAXIMUM
TERMINAL SCREW
TORQUE NOT TO
EXCEED 5 IN-LBS.
0.25 (6,4)
0.25 (6,4)
TERMINAL STRIP FOR
FIELD WIRING
3.50
(88,9)
4.00 (101,6)
4.50 (114,3)
2.20 (55,9)
MAX.
0.75 (19,1)
System 50
4 CHANNEL RACK: G5
Part No. 70GRCK4
Dimensions are shown in inches
(and millimeters).
All tolerances are ± 0.010 (0,25)
unless otherwise specified.
3.25 (82,55)
.25
(6,35)
2.75 (69,85)
5
4
3
2
1
Panel Mount
6
DIN-RAIL CARRIER
7
9 POSITION
TERMINAL
STRIP FOR
CONTROL
LOGIC
8
4.00
(101,6)
2.75
(69,85)
4.70
(119,38)
Y AC INTPUT
W DC INTPUT
.75
(19,05)
.76 (19,30)
4.27
(108,46)
B AC OUTPUT
R DC OUTPUT
3.36
5,34)
SWAGED
STANDOFF
THRU HOLE
.15 (3,81) DIA.
(4 PLACES)
(CLEARANCE
FOR #6 SCREW)
9
9 POSITION
TERMINAL
STRIP FOR
FIELD WIRING
1
2
3
4
5
6
7
8
9
NOTE: MAXIMUM TERMINAL
SCREW TORQUE NOT TO
EXCEED 5 IN-LBS.
DIN-Rail
Mount
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
System 50
4
System 50
SCHEMATICS: Part No. 70RCK4
70RCK4 For Negative True Logic Only
1
2
3
4
5
6
7
8
70RCK4R For Negative or Positive True
Logic
9
1
FIELD WIRING
TERMINAL STRIP
N/C
0
1
2
3
4
5
6
7
8
9
FIELD WIRING
TERMINAL STRIP
FUSE
5A
1
2
3
4
5
2
N/C
FUSE
5A
1
2
3
4
5
3
MODULE
POSITION
0
1
2
3
MODULE
POSITION
3.3K
3.3K
TERMINAL STRIP
FOR LOGIC AND
GROUND SIGNALS
GND
LOGIC
GND
LOGIC
GND
LOGIC
GND
LOGIC
1
2
3
4
5
6
7
8
9
LOGIC
9
+VCC
8
LOGIC
7
+VCC
6
LOGIC
5
+VCC
4
LOGIC
3
+VCC
2
GND
1
+VCC
TERMINAL STRIP
FOR LOGIC AND
GROUND SIGNALS
SCHEMATICS: Part No. 70GRCK4
70GRCK4 and 70GRCK4-DIN For Negative True Logic Only
1
NC
NC
70GRCK4R and 70GRCK4R-DIN For Negative
or Postive True Logic
2
1
2
3
4
5
3
4
5
6
7
8
9
1
BARRIER STRIP
FOR FIELD WIRING
OF MODULE
INPUT/OUTPUT
0
1
2
3
2
3
4
5
6
7
8
9
BARRIER STRIP
FOR FIELD WIRING
OF MODULE
1
2
3
4
5
MODULE
LOCATION
PULL-UP
RESISTOR
3.3 KΩ
0
1
2
3
MODULE
LOCATION
PULL-UP
RESISTOR
3.3 KΩ
System 50
GND
LOGIC
3
4
5
6
7
8
9
LOGIC
LOGIC
4
4
4
4
4
4
2
+VCC
GND
70RCK4
70RCK4R
70GRCK4
70GRCK4R
70GRCK4-DIN
70GRCK4R-DIN
I/O
1
LOGIC
LOGIC
Part Number
9
+VCC
GND
ORDERING INFORMATION
8
LOGIC
7
+VCC
6
LOGIC
5
+VCC
4
CONTROL
BARRIER
STRIP
GROUND
3
LOGIC
2
GND
1
+VCC
CONTROL
BARRIER
STRIP
(modules ordered separately)
Description
UL
CSA
Style
Negative true logic
Positive or negative true logic*
Negative true logic
Positive or negative true logic*
Negative true logic–DIN rail mount
Positive or negative true logic*–
DIN rail mount
X
X
X
X
X
X
X
X
X
X
X
X
Standard
Standard
G5
G5
G5
G5
.
Available from your local Grayhill Distributor. For prices and discounts, contact a local
Sales Office, an authorized local Distributor, or
Grayhill.
*Note: Positive True Logic applies to output modules only.
System 50
5
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com