HAMAMATSU C10083CAH

MODULE
Mini-spectrometer TM series
C10082CA, C10082CAH, C10083CA, C10083CAH
High sensitivity type (integrated with back-thinned type CCD image sensor)
TM series mini-spectrometers are polychromators integrated with optical elements, an image sensor and a driver circuit. Light to be measured is
guided into the entrance port of TM series through an optical fiber and the spectrum measured with the built-in image sensor is output from the
USB port to a PC for data acquisition. They are high sensitivity mini-spectrometers employing a back-thinned type CCD image sensor. Their
sensitivity is about two orders of magnitudes higher than CMOS type making TM series even more ideal for low-light-level measurement.
C10082CAH and C10083CAH are high resolution type (spectral resolution: 1 nm Typ.).
Mini-spectrometer TM series comes supplied with free sample software that allows setting measurement conditions, acquiring and saving data,
and displaying graphs. Driver software and DLL are also supplied as accessory items to allow the users to configure their own measurement
software.
Features
Applications
l Integrated with back-thinned type CCD image sensor:
l Low-light-level measurement such as fluorescence measurement
Sensitivity is about two orders of magnitude higher than
l Semiconductor process control
CMOS type
l Evaluation of light source characteristics such as LED
l High resolution: 1 nm (C10082CAH, C10083CAH)
l High throughput due to transmission grating made of quartz
Comparison of CCD type and CMOS type
l Highly accurate optical characteristics
l Wide spectral response range
■ Output comparison (relative value)
l Easy to install into equipment
l Wavelength conversion factor *1 is recorded in internal memory
C10082CA
C10083CA
C10082CAH
C10082MD
■ O p tic a l c h a ra c te ris tic s
■ E le c tric a l c h a ra c te ris tic s
P a ra m e te r
A /D c o n v e rs io n
In te g ra tio n tim e
In te rfa c e
U S B b us po w er
c u rre n t c o n s u m p tio n
E x te rn a l p o w e r s u p p ly
1 *3
6
8 *4
1 *3, *4
U n it
nm
nm
0 .0 4
n m/° C
-3 0
(Typ. Ta=25 ˚C)
1
10
±0 .2
-3 3
C10083CAH
C10083MD
nm
dB
S p e c ific a tio n
16
1 0 to 1 0 0 0 0
U S B 1 .1
U n it
b it
ms
-
100
mA
5
V
100
RELATIVE SENSITIVITY *
P a ra m e te r
S p e c tra l re s p o n s e ra n g e
S p e c tra l re s o lu tio n M a x.
( S p e ctr al r e s p o n s e h alf wi dt h) * 2
W a v e le n g th re p ro d u c ib ility * 5
W a v e le n g th te m p e ra tu re
d ep ende nce
S p e c tra l s tra y lig h t * 2 , * 6
T M -U V /V IS -C C D
T M -V IS /N IR -C C D
C 1 0 0 8 2 C A C 10082 CA H C 1 0 0 8 3 C A C 10083 CA H
2 0 0 to 8 0 0
3 2 0 to 1 0 0 0
10-1
10-2
10-3
-4
10
10
-5
200
300
400
500
600
700
800
900
1000
WAVELENGTH (nm)
■ G e n e ra l ra tin g s / A b s o lu te m a xim u m ra tin g s
P a ra m e te r
S p e c ific a tio n
U n it
* A/D count when constant light level enters fiber. KACCB0168EA
D im e n s io n s
9 5 (W ) × 9 2 (D ) × 7 6 (H )
mm
B a c k -th in n e d ty p e C C D im a g e s e n s o r
Im a g e s e n s o r
■ Measurable optical power
(S 1 0 4 2 0 -11 0 6 )
N u m b e r o f p ixe ls
2048
p ix e ls
C10082CA (CCD TYPE)
S lit (H ) × (V ) * 7
7 0 × 8 0 0 1 0 × 10 0 0 7 0 × 8 0 0 1 0 × 10 0 0
µm
O p tic a l N A
0 .2 2
0 .11
0 .2 2
0 .11
C o n n e c to r fo r o p tic a l fib e r
S M A 905D
O p e ra tin g te m p e ra tu re * 8
+ 5 to + 4 0
°C
C10082MD (CMOS TYPE)
S to ra g e te m p e ra tu re
-2 0 to + 7 0
°C
*1 : A c o n v e rs io n fa c to r fo r c o n v e rtin g th e im a g e s e n s o r p ixe l n u m b e r in to a
w a v e le n g th is re c o rd e d in th e m o d u le . A c a lc u la tio n fa c to r fo r c o n v e rtin g th e
10-15
10-13
10-11
10-9
10-7
A /D c o n v e rte d c o u n t in to th e in p u t lig h t in te n s ity is n o t p ro v id e d .
LIGHT POWER * (W)
*2 : D e p e n d s o n th e s lit o p e n in g . Va lu e s w e re m e a s u re d w ith th e s lit lis te d in th e
* Light power incident on mini-spectrometer through slit
ta b le “■ G e n e ra l ra tin g s / A b s o lu te m a xim u m ra tin g s ”.
(λ=500 nm, integration time: 10 ms to 10000 ms)
KACCB0146EA
*3 : Ty p ic a l
*4 : λ = 3 2 0 to 9 0 0 nm
*5 : M e a s u re d u n d e r c o n s ta n t lig h t in p u t c o n d itio n s
*6 : W h e n m o n o c h rom a tic lig h t o f th e follo w in g w a v e le n g th s is in p u t, s p e c tra l s tra y lig h t is d e fin e d a s the ra tio o f th e c o u n t m e a su re d a t th e in p u t
w a ve le n g th , to th e c o u n t m ea s u re d in a re g io n o f th e in p u t w a ve le n g th ±4 0 n m .
C 1 0 0 8 2 C A /C 1 0 0 8 2 C A H : 5 0 0 n m , C 1 0 0 8 3 C A /C 1 0 0 8 3 C A H : 6 5 0 n m
*7 : E n tra n c e s lit a p e rtu re s iz e
*8 : N o c o n d e n s a tio n
1
C10082CA, C10082CAH, C10083CA, C10083CAH
Mini-spectrometer TM series
Light spectrally separated by a grating is focused according to light wavelength on predetermined image sensor positions, and high-order light is also input onto positions at integer-multiples of wavelengths. In these mini-spectrometers an
optical filter is attached to the image sensor to cut off high-order light, but this also causes a drop in the image sensor
output at the following wavelengths.
C10082CA/10082CAH: Near 340 nm and 500 nm, C10083CA/C10083CAH: Near 500 nm and 700 nm
Types not using a high-order light cut-off filter are also available. Please specify by adding “-01” to the type number when
ordering. (Example: C10082CA-01)
■ Spectral resolution vs. wavelength
SPECTRAL RESOLUTION (nm)
8.0
C10083CA (Slit width 70 µm, Optical NA 0.22)
C10082CA (Slit width 70 µm, Optical NA 0.22)
C10083CAH (Slit width 10 µm, Optical NA 0.11)
C10082CAH (Slit width 10 µm, Optical NA 0.11)
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
200
300
400
500
600
700
800
900
1000
WAVELENGTH (nm)
KACCB0159EA
■ Optical component layout
■ Connection example (transmission light measurement)
TM series mini-spectrometers use a transmission holographic
grating made of quartz and precision optical components
arranged on a rugged optical base, making it possible to
deliver high throughput and highly accurate optical characteristics.
Light to be measured is guided into the entrance port of TG
series through an optical fiber and the spectrum measured
with the built-in image sensor is output through the USB port
to a PC for data acquisition. There are no moving parts inside
the unit so stable measurements are obtained at all times. An
optical fiber that guides light input from external sources allows a flexible measurement setup.
ENTRANCE SLIT
COLLIMATING LENS
TRANSMISSION GRATING
AC ADAPTER
(Accessories)
FOCUSING MIRROR
IMAGE SENSOR
KACCC0287EA
HIGH POWER UV-VIS FIBER LIGHT SOURCE
(Deuterium lamp and Halogen lamp)
L10290
PC
USB CABLE
MINI-SPECTROMETER
FIBER
QUARTZ CELL
(For holding liquid sample)
KACCC0317EA
2
Mini-spectrometer TM series
C10082CA, C10082CAH, C10083CA, C10083CAH
■ Dedicated software package (supplied with unit)
Installing the dedicated software package (containing sample software, device driver, DLL)*9 into your PC allows running the
following basic tasks:
· Measurement data acquisition and save
· Measurement condition setup
· Module information acquisition
(wavelength conversion factor, polychromator type, etc.)
· Graphic display
· Arithmetic operation
Pixel number to wavelength conversion
Dark subtraction
Comparison calculation with reference data
(transmittance, reflectance)
Gaussian approximation
(peak position and count, FWHM)
Note: Two or more mini-spectrometers can be
connected and used with one PC
simultaneously.
*9: Compatible OS: Microsoft Windows
Professional Edition 2000
(SP3 or later) and XP (SP1a or later)
Device driver and DLL for controlling hardware are also provided.
You can develop your own measurement programs by using a software development environment that includes Microsoft Visual
C++ and Visual Basic.*10 The DLL provides functions such as USB port open/close, measurement condition setup, measurement
data and module information acquisition.
*10: Operation of the device driver and DLL has been verified only with Microsoft Visual C++® and Visual Basic®.
Microsoft Visual C++ and Microsoft Visual Basic are either registerd trademarks or trademarks of Microsoft Corporation in the
United States and other countries.
■ Measurement example (C10083CA)
■ Dimensional outline (unit: mm)
Fluorescence measurement of quinine solution (1000 ppm)
95
2500
1500
1000
500
76
AD COUNT
92
2000
0
300
400
500
600
700
800
900
1000
WAVELENGTH (nm)
KACCB0145EA
KACCA0188EC
3
Mini-spectrometer TM series
C10082CA, C10082CAH, C10083CA, C10083CAH
■ Accessories
· USB cable
· Dedicated software (sample software, device driver, DLL)
· AC adapter (for power supply)
■ Options (sold separately)
Optical fibers for light input
Type. No
A9762-01
n
Product name
Core diameter (µm)
Fiber for UV/visible range
(resistance to UV)
Specification
N.A.=0.22, length 1.5 m,
connectorized SMA905D at both ends
600
Mini-spectrometer line-up
Type No.
Type
C10082CAH
TM-UV/VIS-CCD
High resolution
C10082MD
C10083CA
TM series
C10082CA
TM-UV/VIS-CCD
High sensitivity
Spectral response range (nm)
200
400
C9404CA
C9404MC
C9405CA
1200
1400
1600
1800
2000
2200
6
TM-VIS/NIR-CCD
High sensitivity
320 to 1000
(λ=320 to 900 nm)
CMOS linear
image sensor
TG-UV-CCD
High sensitivity
3
Back-thinned type
CCD image sensor
1*
Back-thinned type
CCD image sensor
3
CMOS linear
image sensor
High resolution
200 to 400
TG-UV-MOS
Wide dynamic range
Back-thinned type
5
(λ=550 to 900 nm) CCD image sensor
TG-SWNIR-CCD
High sensitivity
C9406GC
Non-cooled type
5
(λ=550 to 1100 nm)
TG series
TG-NIR
NMOS linear
image sensor
7
900 to 1700
TG-cooled NIR-I
7
Low noise (cooled type)
TG-cooled NIR-II
RC-VIS-MOS
340 to 780
Spectrometer module
InGaAs linear
image sensor
8
1100 to 2200
Low noise (cooled type)
RC
series
CMOS linear
image sensor
8
TG-SWNIR-MOS
Wide dynamic range
C9407MA
Back-thinned type
CCD image sensor
TM-VIS/NIR-MOS
Wide dynamic range
C9405MC
C9914GB
Image sensor
8
(λ=320 to 900 nm) Back-thinned type
CCD image sensor
1*
500 to 1100
C9913GC
Spectral resolution
Max.
(nm)
1*
TM-UV/VIS-MOS
Wide dynamic range
TG-UV-CCD
TG series
C9404CAH
1000
200 to 800
High resolution
C10083MD
800
6
TM-VIS/NIR-CCD
C10083CAH
600
9
CMOS linear
image sensor
Spectral resolution
Max.
(nm)
Image sensor
9
CMOS linear
image sensor
* Typ.
OEM model
C9409MA
Type
RC
series
Type No.
RC-VIS-MOS
Spectrometer head
Spectral response range (nm)
200
400
600
340 to 780
800
1000
1200
1400
1600
1800
2000
2200
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions.
Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2007 Hamamatsu Photonics K.K.
HAMAMATSU PHOTONICS K.K., Solid State Division
1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184, www.hamamatsu.com
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P.O.Box 6910, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 08152-3750, Fax: (49) 08152-2658
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777
North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171 41 Solna, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01
Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741
Cat. No. KACC1126E02
4
Oct. 2007 DN