QFN12L (3 x 3 mm)
Features
• Low Insertion Loss : 0.8 dB @ 2.5 GHz
•
•
•
•
1.0 dB @ 4.9 to 6.0 GHz
High Isolation: 43 dB @ 2.5 GHz
36 dB @ 4.9 to 6.0 GHz
Low DC Power Consumption
Miniature QFN12L (3x3 mm) Plastic Package
PHEMT process
Description
The HWS411 is a GaAs PHEMT MMIC DPDT
switch operating at DC-6 GHz in a low cost
miniature QFN12L (3 x 3 mm) plastic package. The
HWS411 features low insertion loss and high
isolation up to 6 GHz with very low DC power
consumption. This switch can be used in IEEE
802.11a/b/g WLAN systems for combination of
transmit/receive and antenna diversity functions.
Electrical Specifications at 25°C with 0, +3V Control Voltages
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
1.3
dB
dB
dB
0.1-6.0 GHz
2.4-2.5 GHz
4.9-6.0 GHz
1.0
0.8
1.0
Isolation
(on/off or off/on)
0.1-6.0 GHz
2.4-2.5 GHz
4.9-6.0 GHz
36
43
36
dB
dB
dB
Isolation
(off/off)
2.4-2.5 GHz
4.9-6.0 GHz
10
17
dB
dB
Return Loss
0.1-6.0 GHz
2.4-2.5 GHz
4.9-6.0 GHz
15
20
18
dB
dB
dB
Input Power for One dB
Compression
2.0-6.0 GHz
30
dBm
Second Harmonic
Pin=20 dBm
-75
dBc
Third Harmonic
Pin=20 dBm
-75
dBc
20 dBm Per Tone @ 5.85 GHz
45
dBm
Switching Time
50
ns
Control Current
5
Insertion Loss
Input Third Order Intermodulation
Intercept Point
26
100
uA
Note: All measurements made in a 50 ohm system with 0/+3.0V control voltages, unless otherwise specified.
Hexawave Inc.
2 Prosperity Road II, Science Park, Hsinchu, Taiwan. TEL 886-3-578-5100 FAX 886-3-577-0512
http://www.hw.com.tw
All specifications are subject to change without notice.
V3
HWS411
October 2004
Typical Performance Data with 8pF
Capacitors @ +25°C
Absolute Maximum Ratings
Parameter
Insertion Loss vs Frequency
-0.4
-0.6
-0.8
Absolute Maximum
RF Input Power
+32 dBm @ +3V
Control Voltage
+6V
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
Pin Out (Top View)
B
-1.2
2.0
2.5
3.0
3.5 4.0 4.5 5.0
Frequency(GHz)
5.5
B
-1.0
6.0
12
11
10
1
9
-20
2
8
-30
3
7
Isolation vs Frequency
4
5
6
B
-40
-50
B
Insertion Loss(dB)
-0.2
Isolation(dB)
V3
-60
-70
-80
2.0
2.5
3.0
3.5 4.0 4.5 5.0
Frequency(GHz)
5.5
6.0
Return Loss vs Frequency
0
Logic Table for Switch On-Path
-10
Return Loss(dB)
Note:
1. DC blocking capacitors CB=8pF are required on all
RF ports.
2. Exposed pad in the bottom must be connected to
ground by via holes.
3. TX and RX ports can be used interchangeably.
VC1
VC2
ANT1-RX ANT1-TX ANT2-TX ANT2-RX
-20
1
0
On
Off
On
Off
-30
0
1
Off
On
Off
On
1
1
Off
Off
Off
Off
0
0
Off
Off
Off
Off
-40
-50
2.0
2.5
3.0
Hexawave Inc.
3.5 4.0 4.5 5.0
Frequency(GHz)
5.5
6.0
‘1’ = +3V to +5V
‘0’ = 0V to +0.2V
2 Prosperity Road II, Science Park, Hsinchu, Taiwan. TEL 886-3-578-5100 FAX 886-3-577-0512
http://www.hw.com.tw