Features
QFN12L (3 x 3 mm)
• Low Insertion Loss : 0.75 dB @ 2.50 GHz
1.25 dB @ 5.85 GHz
• Isolation: 25.5 dB @ 2.50 GHz
14.5 dB @ 5.85 GHz
• Low DC Power Consumption
• Miniature QFN12L (3x3 mm) Plastic Lead (Pb)
Free Package, RoHS Compliant
• PHEMT process
Description
The HWS453 is a GaAs PHEMT MMIC DPDT
switch operating at DC-6 GHz in a low cost
miniature QFN12L (3 x 3 mm) plastic lead (Pb) free
package. The HWS453 features low insertion loss
and high isolation with very low DC power
consumption. This switch can be used in IEEE
802.11a/b/g WLAN systems for combination of
transmit/receive and antenna diversity functions.
Electrical Specifications at 25°C with 0, +3V Control Voltages
Parameter
Insertion Loss
Isolation
(on-off or off-on)
Typ.
Max.
Unit
0.10-6.00 GHz
2.40-2.50 GHz
5.15-5.85 GHz
1.25
0.75
1.25
1.00
dB
dB
dB
0.10-6.00 GHz
2.40-2.50 GHz
5.15-5.85 GHz
14.0
Input Power for One dB
Compression
Input Third Order Intermodulation
Intercept Point
Min.
20.0
dB
dB
25.5
14.5
15
dB
20
dB
15
dB
2.00-6.00 GHz
34
dBm
20 dBm Per Tone @ 2.50 GHz
22 dBm Per Tone @ 5.85 GHz
52
dBm
52
dBm
0.10-6.00 GHz
2.40-2.50 GHz
5.15-5.85 GHz
Return Loss
Control Current
Test Conditions
5
dB
200
uA
Note: All measurements made in a 50 ohm system with 0/+3.0V control voltages, unless otherwise specified.
Hexawave Inc.
2 Prosperity Road II, Science Park, Hsinchu, Taiwan. TEL 886-3-578-5100 FAX 886-3-577-0512
http://www.hw.com.tw
All specifications are subject to change without notice.
V2
HWS453
GaAs DC-6 GHz DPDT Switch
September 2006
Parameter
Insertion Loss vs Frequency
Absolute Maximum
RF Input Power
+34 dBm @ +3V
Control Voltage
+6V
Operating Temperature
-40°C to +85°C
-0.8
Storage Temperature
-65°C to +150°C
-1.0
Pin Out (Top View)
-1.2
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
GND
-1.4
12
Frequency(GHz)
Isolation vs Frequency
-5
CB
TX
RX
-0.6
CB
Insertion Loss(dB)
-0.4
2.0
V2
Absolute Maximum Ratings
Typical Performance Data with 8pF
Capacitors @ +25°C
11
10
GND 1
9
GND
GND 2
8
GND
3
7
VC1
VC2
4
ANT2
-25
6
CB
CB
-20
5
GND
-15
ANT1
Isolation(dB)
-10
-30
-35
2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
Frequency(GHz)
Return Loss vs Frequency
-5
Note:
1. DC blocking capacitors CB=8pF are required on all
RF ports.
2. Exposed pad in the bottom must be connected to
ground by via holes.
3. TX and RX ports can be used interchangeably.
Logic Table for Switch On-Path
Return Loss(dB)
-10
-15
VC1
-20
1
0
On
Off
On
Off
-25
0
1
Off
On
Off
On
-30
1
1
Off
Off
Off
Off
-35
0
0
Off
Off
Off
Off
2.0
2.5
3.0
3.5
4.0
4.5
Frequency(GHz)
Hexawave Inc.
5.0
5.5
VC2 ANT1-RX ANT1-TX ANT2-TX ANT2-RX
6.0
‘1’ = +3V to +5V
‘0’ = 0V to +0.2V
2 Prosperity Road II, Science Park, Hsinchu, Taiwan. TEL 886-3-578-5100 FAX 886-3-577-0512
http://www.hw.com.tw
All specifications are subject to change without notice.