ETC 41FJ020

Power Transformer
41FJ020
2.24
2.74
1.25
2.28
6.69
.390
2-.260 x .190
1
5
4
2
3
3.25
3.65
Dimensions: In.
Specifications:
• Primary voltage: 115VAC 60Hz
• Primary exciting current: 100mA (max.)
• Secondary voltage (no load): 20.6CT VAC±0.8V%
• Secondary voltage (full load): 18.0CT VAC±0.8V%
• Rated secondary current: 2.0 Amperes (AC) 60Hz
• Voltage regulation: less than 15% (VNL-VFL)/(VFL)x100
• Temperature rise (@ room temp. 25˚C): less than 95˚C
• Breakdown voltage (HiPOT): 2000VAC 50Hz, 1minute
• Coil to coil insulation: 100MΩ (min.) 500VDC
• Strain relief: 10 lbs.
• Channel frame material & thickness: iron 0.4"
• Crossover insulation: .002" polyester tape
• Primary winding: SWG28
• Secondary winding: SWG22+28
• Core size: EI-66
• Core material: hilite core H-23 .02"
• Inner insulation: 3 layers of .002" polyester tape
• Outer wrap insulation: 3 layers of 0.05mm polyester
tape w/1 pc. of fiber board (yellow)
• Bobbin: nylon, normal type .87" x 1.8"
• Impregnation: varnish
• Lead wire: Pri. AWG22, Sec. AWG18 or AWG22
XICON PASSIVE COMPONENTS • (800) 628-0544
XC-600072
Date Revised: 11/2/05
Specifications are subject to change without notice. No liability or warranty implied by this information. Environmental compliance based on producer documentation.