Power Transformer 41FJ020 2.24 2.74 1.25 2.28 6.69 .390 2-.260 x .190 1 5 4 2 3 3.25 3.65 Dimensions: In. Specifications: • Primary voltage: 115VAC 60Hz • Primary exciting current: 100mA (max.) • Secondary voltage (no load): 20.6CT VAC±0.8V% • Secondary voltage (full load): 18.0CT VAC±0.8V% • Rated secondary current: 2.0 Amperes (AC) 60Hz • Voltage regulation: less than 15% (VNL-VFL)/(VFL)x100 • Temperature rise (@ room temp. 25˚C): less than 95˚C • Breakdown voltage (HiPOT): 2000VAC 50Hz, 1minute • Coil to coil insulation: 100MΩ (min.) 500VDC • Strain relief: 10 lbs. • Channel frame material & thickness: iron 0.4" • Crossover insulation: .002" polyester tape • Primary winding: SWG28 • Secondary winding: SWG22+28 • Core size: EI-66 • Core material: hilite core H-23 .02" • Inner insulation: 3 layers of .002" polyester tape • Outer wrap insulation: 3 layers of 0.05mm polyester tape w/1 pc. of fiber board (yellow) • Bobbin: nylon, normal type .87" x 1.8" • Impregnation: varnish • Lead wire: Pri. AWG22, Sec. AWG18 or AWG22 XICON PASSIVE COMPONENTS • (800) 628-0544 XC-600072 Date Revised: 11/2/05 Specifications are subject to change without notice. No liability or warranty implied by this information. Environmental compliance based on producer documentation.