ETC AAV002-11

11409 Valley View Road
Eden Prairie, MN 55344
Phone: (952) 829-9217
Fax: (952) 996-1600
Preliminary Data Sheet
NVE AAV001-11, AAV002-11
Spin Valve GMR Bridge Sensor
•
•
•
•
•
•
For Angle Detection and Magnetic Encoder Applications
Sine and Cosine Outputs Available
Utilizes Spin Valve GMR Material
Precise Detection of Magnetic Field
Ultra – Small PLLP Package
Cannot Be Damaged By Large Magnetic Fields
Description – The AAV001-11 and AAV002-11 are arrays of four GMR resistors, rotated at 90
degree intervals in the package. The AAV001-11 features independent resistors that can be wired
together to form two half bridges, or used as independent resistors. The AAV002-11 has the bridge
connections made internally to the package. For either part, the output can be configured to represent
the sine and cosine function of the magnetic field being applied to the sensor. Each resistor is 1.2KOhms
nominal resistance, and output of each half bridge is ratiometric with the power supply voltage. The part
features NVE’s PLLP6 housing, which is a 3.0mm X 3.0mm X 0.9mm thick surface mount package.
Operation – The end user must apply a magnetic field planar with the IC package.
As this magnetic
field varies, the resistance values of the individual resistors change and output is provided by the half
bridges. An example output signal is shown in the diagram below:
Sine and Cosine Output from AAV Sensors
Voltage Output (5V Supply)
2.58
2.56
2.54
2.52
Sine
2.5
Cosine
2.48
2.46
2.44
2.42
0
90
180
270
360
Degrees of Rotation
Rhopoint Components Ltd
Hurst Green, Oxted, Surrey. RH8 9AX
Telephone:- +44 (0)870 608 1188 Fax:- +44 (0)870 241 2255
Web Site:- www.rhopointcomponents.com
Functional Block Diagram and Pinout:
Cosine Output
AAV001-11
R3
R2
R3 (Cosine)
Sine Output
R2 (Sine)
VCC
GND
R1 (Sine)
R4 (Cosine)
R1
R4
AAV002-11
VCC
R3 (Cosine)
Sine Output
Sin
R2 (Sine)
Cos
R1 (Cosine)
Cosine Output
R4 (Sine)
GND
Rhopoint Components Ltd
Hurst Green, Oxted, Surrey. RH8 9AX
Telephone:- +44 (0)870 608 1188 Fax:- +44 (0)870 241 2255
Web Site:- www.rhopointcomponents.com
Specifications:
Parameter
Nominal Resistance of Each Resistor
Maximum Resistance Decrease with Field
Rotation
Required Strength of Applied Magnetic Field
Accuracy Error of Angular Measurement
Supply Voltage
Offset Voltage
Temperature Range of Operation
Storage Temperature
Temperature Coefficient of Resistance
3
TCOV
Test
Condition
25C
Operating at
25C
Operating
Operating
Operating
Operating at
25C
Operating
Operating
Operating
Min
Typ
Max
Units
900
4.5%
1200
5.2%
1500
6.0%
Ohms
-10
200
2
12
10
Oersted
Degrees
Volts
mV/V
-40
-40
150
170
°C
°C
%/°C
%/°C
30
+0.3
-0.4
Notes:
1. Large Magnetic Fields WILL NOT cause damage to NVE GMR Sensors
2. 1 Oe (Oersted) = 1 Gauss in air = 0.1 mT
3. TCOV is the percent change in output signal over temperature, with a constant voltage source powering the part
PLLP6 Package Dimensions (mm [inches]):
Rhopoint Components Ltd
Hurst Green, Oxted, Surrey. RH8 9AX
Telephone:- +44 (0)870 608 1188 Fax:- +44 (0)870 241 2255
Web Site:- www.rhopointcomponents.com
2