ETC B12A12005L310100U253

Thermal motor protector
Temperature limiter
Thermal cut-out
B
12
Applications
- Motors
- Transformers
- Coils
- Electronics, sensors
Benefits
- Non-sensitive to current
- High current rating up to 30A
- Manifold executions
CANTHERM
Technical data
control type
ratings
version
rated current at 250 V 50/60 Hz ( power factor 0.95 / 0.6 )
B12A / E
B12B / G
normally closed
normally open
6.3 A / 4.0 A
10.0 A / 6.0 A
13.0 A / 2.1 A
5.0 A / 1.6 A
10,000
5,000
1,000
5,000
switching cycles
max. current at 250 V 50/60 Hz ( power factor 0.95 )
30.0 A
switching cycles under max. current
100
temperature rating Ta ( steps in 5 K )
70 °C ... 160 °C
tolerances
Standard: ± 5 K
feature of automatic action
1.B.M, 2.B, 1.C, 3.C
contact resistance ( incl. wire of 100 mm )
< 50 m
hysteresis
30 K ± 15 K
dielectric strength ( standard insulation )
2 kV
shock- / vibration testing ( similar to EN 50155 )
400 m/s2 sine half wave / 100 m/s2 5 Hz ... 2.000 Hz sine
resistances to impregnation
tight against ordinary resins and lacquers
degrees of protection provided by enclosures ( EN 60529 )
IP00
suitable for use in protection category
I, II
VDE / ENEC
approvals
EN 60730-1 / -2-2 / -2-3 1) /-2-9
UL
UL 2111 / UL 873 2)
C22.2 No. 77 / C22.2 No. 24 2)
CSA
1)
2)
1.B, 3.C
different power rating
on demand
Standard wire (length 100 ± 10 mm, stripped 6 ± 1 mm)
lead
code
temperature
max.
operating
voltage max.
L310
150 °C
stranded
white
L340
1.80 mm
AWG20 / 0.48 mm2
2.15 mm
AWG18 / 0.96 mm2
1.26 mm
AWG20 / 0.62 mm2
1.50 mm
AWG18 / 0.96 mm2
UL
style
3398
600 V
L350
solid
yellow
cross section
diameter
300 V
L320
200 °C
diameter
insulation
3557
L410
150 °C
300 V
1.65 mm
AWG20 / 0.81 mm
3398
L440
200 °C
300 V
1.71 mm
AWG20 / 0.81 mm
1332
Standard insulation
control
type
nc
no
code
illustration
drawing
dimensions ( mm )
technical
specification
approvals
VDE, UL
VDE, UL
B12
A
B
U253
shrink cap
potted
Attention:
Ta max. 155 °C
B12
A
B
U186
cap of PPS
potted
Specific variations
control
type
nc
no
B12
A
B
B12
A
B
B12
A
B12
A
B12
B12
E
E
technical
specification
approvals
not insulated
potted
VDE, UL,
CSA
U112
coated
VDE, UL
B
U294
housing of PPS
potted
VDE, UL
B
A800
not insulated
potted
VDE, UL
G402
aluminium housing
thread M4x6
potted
Attention:
Ta max. 150 °C
VDE, UL
G714
brass housing
thread M4x5
potted
Attention:
Ta max. 150 °C
VDE, UL
G
G
code
illustration
drawing
dimensions ( mm )
heating [K]
Heating by current
current [A]
The diagram is measured with a thermal control without any insulation in an oil bath.
Attention:
The heating depends on the thermal conduction of the control to the equipment or part which should be
protected.
Ordering and marking example
Ordering example
B12
A
120
Marking
05 L310 100 U253
B12A
type (B12 nc)
12005 response temperature (120°C), tolerance (± 5K)
shrinkcap insulation
length 100 mm
lead wire white, AWG20
tolerance
temperature
normally closed
026D
date of manufacture (Feb.2006), country (D=Germany)
type
Deviations from standard controls on request.
Representation office:
CANTHERM
8415 Mountain Sights Avenue • Montreal (Quebec), H4P 2B8, Canada
Tel: (514) 739-3274 • 1-800-561-7207 • Fax: (514) 739-290
E-mail : [email protected] • Website: www.cantherm.com
09.2006 Subject to change without notice