Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink • AC Solid State Contactor, 1- and 2 poles • Zero switching for heating and motor applications • Instant-on switching • Rated operational current 30 A, 50 A and 63 A • Rated operational voltage 230 VAC, 400/480 VAC • Transient overvoltage protection built-in • LED-indication • IP 20 protection • DIN-rail mountable Product Description The SOLITRON Solid State Contactor is designed for industrial heating and motor control applications. The Solid State Contactor is capable of switching 1-, 2-, and 3-phase applications with loads up to 63 A AC1 load and up to 24 A AC3 load. The Solid State Contactor is designed for DINrail mounting with integrated heatsink and overvoltage protection. The heatsink is moved to the front for optimal convection cooling in the panel. Cable ducting system will not stop the airflow. The contactor elements are soldered directly on to the direct copper bonded substrate (DCB-technology). AC or DC controlled versions are available. Built-in LED status indication for applied control voltage. Ordering Key RN 1 A 23 A 50 Solid State Relay Number of poles Switching type A: Zero switching B: Instant on switching Rated operational voltage Control voltage Rated operational current Type Selection, 1 Pole Rated operational voltage Control voltage Rated operational current AC51: 30 A AC51: 50 A AC53a: 6 A AC53a: 12 A AC51: 63 A AC53a: 24 A 230 VAC 5-32 VDC 5-32 VDC 24-230 ± 15% VAC/DC RN 1A23D30 RN 1B23D30 RN 1A23A30 RN 1A23D50 RN 1B23D50 RN 1A23A50 RN 1A23D63 RN 1B23D63 RN 1A23A63 400/480 VAC 5-32 VDC 5-32 VDC 24-230 ± 15% VAC/DC RN 1A48D30 RN 1B48D30 RN 1A48A30 RN 1A48D50 RN 1B48D50 RN 1A48A50 RN 1A48D63 RN 1B48D63 RN 1A48A63 Type Selection, 2 Pole Rated operational voltage Control voltage Rated operational current AC51: 30 A Total AC51: 50 A Total AC53a: 6 A AC53a: 12 A 230 VAC 5-32 VDC 5-32 VDC 24-265 VAC/DC RN 2A23D30 RN 2B23D30 RN 2A23A30 RN 2A23D50 RN 2B23D50 RN 2A23A50 400/480 VAC 5-32 VDC 5-32 VDC 24-265 VAC/DC RN 2A48D30 RN 2B48D30 RN 2A48A30 RN 2A48D50 RN 2B48D50 RN 2A48A50 2-88 Specifications are subject to change without notice (08.05.2002) RN 1 A 23 A 50 General Specifications RN..23... RN..48... Operational voltage range Non-rep. peak voltage Varistor voltage Operational frequency range Power factor at rated voltage Approvals CE-marking 24 to 265 VAC 800 Vp 275 VAC 45 to 65 Hz ≥ 0.5 UL, cUL, CSA Yes 42 to 530 VAC 1200 Vp 510 VAC 45 to 65 Hz ≥ 0.5 UL, cUL, CSA Yes Norms fulfilled Low-voltage controlgear semiconductor contactors Generic Immunity Standard. Industrial Environment HD 419.2S1 EN 50082-2 Input Specifications Rated control voltage range RN1 RN2 Pick-up voltage Drop-out voltage Reverse voltage max. Input current RN1 RN2 Response time Pick-up time max. (50 Hz) RN1A RN.B Drop-out time max. (50 Hz) RN.A RN.B Input-ON indication (LED, green) RN....D RN....A.. 5 to 32 VDC 2 x 5 to 32 VDC 4 VDC 3 VDC 32 VDC 24 to 265 VAC/DC 2 x 24 to 265 VAC/DC 14 VAC/DC 6 VAC/DC - < 9 mA < 9 mA per pole < 12 mA < 12 mA per pole 10 ms < 1 ms 20 ms - 10 ms 10 ms Yes 20 ms Yes Output Specifications Rated operational current RN1A.. AC51 @Ta=30°C “ @Ta=40°C “ @Ta=50°C “ @Ta=60°C AC53a @Ta=40°C RN2A.. AC51 @Ta=30°C “ @Ta=40°C “ @Ta=50°C “ @Ta=60°C AC53a @Ta=40°C Zero crossing detection Min. operational current Rep. overload current t=1 s (Tj init.=25°C) Non-rep. surge current t=10 ms (Tj init.=25°C) Off-state leakage current, @ rated voltage and frequency (Tj.=125°C, max.) I2t for fusing t=1 to 10 ms Critical dV/dt off-state RN.....30 RN.....50 RN.....63 30 A 30 A 23 A 20 A 6A 30 A total 30 A total 23 A total 20 A total 6A Yes 200 mA 50 A 50 A 38 A 30 A 12 A 50 A total 50 A total 38 A total 30 A total 12 A Yes 200 mA 63 A 50 A 40 A 30 A 24 A Yes 200 mA sum sum sum sum sum sum sum sum 55 AACrms 125 AACrms 150 AACrms 250 Ap 600 Ap 1000 Ap < 1 mA 310 A2s 500 V/µs < 1 mA 1800 A2s 500 V/µs < 1 mA 5000 A2s 500 V/µs Specifications are subject to change without notice (08.05.2002) 2-89 RN 1 A 23 A 50 Thermal Specifications Operational temperature Storage temperature Junction temperature Rth junction to ambient (AC load) RN.....30 RN.....50 RN.....63 -20 to +70°C (-4 to +158°F) -40 to +100°C (-40 to +212°F) < 125°C (257°F) 2.8 K/W -20 to +70°C (-4 to +158°F) -40 to +100°C (-40 to +212°F) < 125°C (257°F) 1.7 K/W -20 to +70°C (-4 to +1580F) -40 to +100°C (-40 to +212°F) < 125°C (257°F) 1.5 K/W Housing Specifications Insulation Mounting Weight with RHN1 Weight with RHN2 Housing material Rated impulse withstand voltage Input to output 4000 Vimp Rated impulse withstand voltage Output to heatsink 4000 Vimp LED window material Base plate Potting compound Terminals Control terminals nominal Min. Mounting torque max. Power terminals nominal Min. Mounting torque max. Heatsink compound used DIN-rail 35 mm 470 g 780 g Glass reinforced noryl SE1GFN1 PC Lexan 141R Aluminium, nickel-plated Polyurethane, Casco Nobel Screw with captive wire clamp 4 mm2 or 2 x 2.5 mm2 AWG 12 or 2 x AWG 14 0.5 mm2, AWG 20 0.6 Nm 10 mm2 or 2 x 6 mm2 AWG 6 or 2 x AWG 10 1 mm2, AWG 16 2.0 Nm Dow Corning 340 Environment Specifications Humidity max. 95%, no condensation Dimensions Dimensions with RHN 1 (30 A) (H x W x D) 120 x 45 x 110 mm Dimensions with RHN 2 (50, 63 A) (H x W x D) 120 x 90 x 110 mm Wiring Diagrams 2-pole RN... 1-pole RN... L+/L A1 L+/L A1 Control input L-/L A2 L1 ---/ ~ T1 Control input ---/ ~ L-/L A2 T1 L+/L A3 L2 Control input L-/L A4 2-90 L1 ---/ ~ T2 Specifications are subject to change without notice (08.05.2002) RN 1 A 23 A 50 Terminal Layout Functional Diagrams 1-pole RN... 2-pole RN.. 1-pole RN.. L+/L A1 Control - - - / input L-/L L1 A1 L1 L2 A1 L1 ~ A2 A3 T1 2-pole RN... L1 L+/L A1 Control input 1 - - - / L-/L ~ A2 T1 L2 T1 A2 T1 T2 A2 A4 L+/L A3 Control input 2 - - - / L-/L ~ A4 Shown with RHN1 T2 Applications Single and double pole relay application Line-Neutral Line-Line L1 L2/N Double pole relay in 3-phase application Delta and star application (Economy Switch) L1 L2 L3 Specifications are subject to change without notice (08.05.2002) Two single pole relays in 3-phase application Delta and star. (Economy Switch) L1 L2 L3 2-91 RN 1 A 23 A 50 Applications (cont.) Single and double pole relay in 3-phase application Delta, Star, Star with neutral 3 single pole relays in 3-phase application Delta, Star, Star with neutral L1 L2 L3 N L1 L2 L3 N Dimensions 89 103 37 70 120 71,6 20 37 45 71,6 93 45 4 4 20 70 120 60 60 30 30 103 72 33,7 Note: all dimensions in mm RHN 1 2-92 Note: all dimensions in mm RHN 2 Specifications are subject to change without notice (08.05.2002)