ETC CX1599

CX1599
Hydrogen-Filled Ceramic Thyratron
The data to be read in conjunction with the Hydrogen
Thyratron Preamble.
ABRIDGED DATA
Hydrogen-filled tetrode thyratron with ceramic envelope,
featuring extremely low jitter, low anode delay time drift and
high rate of rise of current. A hydrogen reservoir operating
from a separate, variable heater supply is incorporated.
CX1599 is a fast, precise switch originally designed for use in
pulse generators to drive Kerr cells, Pockel cells or spark
chambers. Anode voltage must be command charged and
applied for less than 10 ms. The tube geometry allows it to be
mounted in a coaxial housing in order to minimise the total
circuit inductance.
Peak forward anode voltage (see note 1) . 12.5
kV max
Peak anode current . . . . . . .
1000
A max
Anode heating factor . . . . . . 12.5 x 107 VApps max
Peak output power . . . . . . . . .
6.25 MW max
Rate of rise of anode current
(see notes 2 and 3) . . . . . . . . 100
kA/ms
Typical jitter (see note 3) . . . . . . .
0.2
ns
Typical p.r.f. . . . . . . . . . . . 10
Hz
GENERAL
Electrical
Cathode (connected internally
to one end of heater) . . . . . . . .
. . . . .
oxide coated
+ 0.0
6.8
Vdc
7 0.3
9.5
A
. . . . .
. . . . .
. . . . .
4.0
1.5
5.0
Cathode heater voltage (see note 3) . . .
Cathode heater current . .
Reservoir heater voltage
(see note 4) . . . . .
Reservoir heater current . .
Tube heating time (minimum)
V nom
A
minutes
Mechanical
Seated height . . . .
Clearance required below
mounting flange . . .
Overall diameter
(mounting flange) . .
Net weight . . . . .
Mounting position (see note
Tube connections . . .
.
79.38 mm (3.125 inches) max
. . 31.75 mm (1.250 inches) min
.
57.15 mm (2.250 inches) nom
. . . 284 g (10 ounces) approx
5) . . . . . . . . . any
. . . . . . . . see outline
Cooling . . . . . . . .
natural, forced-air or liquid
Where natural cooling is insufficient to maintain the envelope
temperatures below the specified rated values, cooling by
forced-air, or by oil or coolant immersion may be used.
The temperature of the anode terminal and the base, measured
at the points indicated on the outline drawing, must not exceed
the values specified below.
Anode terminal . . . . . . . . . . 250
8C max
Base . . . . . . . . . . . . . 220
8C max
e2v technologies limited, Waterhouse Lane, Chelmsford, Essex CM1 2QU England Telephone: +44 (0)1245 493493 Facsimile: +44 (0)1245 492492
e-mail: [email protected] Internet: www.e2vtechnologies.com
Holding Company: e2v holdings limited
e2v technologies inc. 4 Westchester Plaza, PO Box 1482, Elmsford, NY10523-1482 USA Telephone: (914) 592-6050 Facsimile: (914) 592-5148
e-mail: [email protected]
# e2v technologies limited 2004
A1A-CX1599 Issue 4, June 2004
282G/2298
FAST RISE TIME PULSE GENERATOR SERVICE
MAXIMUM AND MINIMUM RATINGS (Absolute values)
Min
Typical
Max
Anode
Peak forward anode voltage (see note 1)
Peak inverse anode voltage (see note 6)
Peak anode current . . . . . . .
Pulse duration . . . . . . . . .
Rate of rise of anode current (see notes 2
Anode heating factor . . . . . . .
. . .
. . .
. . .
. . .
and 7)
. . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
–
–
–
–
–
–
–
–
–
–
–
–
500
–
5.0
0.3
–
–
12.5
12
1000
0.5
100
12.5 x 107
kV
kV
A
ms
kA/ms
VApps
750
5.0
–
–
7200
1000
V
ms
ns
ms
V
O
Grid 2
Unloaded grid 2 drive pulse voltage (see note
Grid 2 pulse duration . . . . . . . .
Rise time of grid 2 pulse (see note 2) . .
Grid 2 pulse delay . . . . . . . . .
Loaded grid 2 bias voltage (see note 9) . .
Forward impedance of grid 2 drive circuit .
8)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
250
. 0.1
. –
. 0.25
725
50
8)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
300
500
750
V
. 0.3
–
–
ms
. 1.0
–
–
kV/ms
. . . . . . . . . . . . . . . . . see note 10
. 2.0
–
50
A
Grid 1 – Pulsed
Unloaded grid 1 drive pulse voltage (see note
Grid 1 pulse duration . . . . . . . .
Rate of rise of grid 1 pulse (see note 2) . .
Loaded grid 1 bias voltage . . . . . .
Peak grid 1 drive current (see note 9) . .
Cathode
Heater voltage (see note 3) . . . . . . . . . . . . . . .
Heating time
. . . . . . . . . . . . . . . . . . .
–
5.0
6.8
–
–
–
V dc
min
4.0
5.0
–
–
7.5
–
Reservoir
Reservoir voltage (see note 4) . . . . . . . . . . . . . .
Heating time
. . . . . . . . . . . . . . . . . . .
V
min
Environmental
Ambient temperature . . . . . . . . . . . . . . . . 720
Altitude . . . . . . . . . . . . . . . . . . . . . –
–
–
–
–
+130
3
10 000
8C
km
feet
CHARACTERISTICS
Critical DC anode voltage for conduction
Anode delay time (see note 11) . . .
Anode delay time drift (see note 12) . .
Time jitter (see note 3) . . . . . .
Recovery time . . . . . . . . .
Heater current (at 6.8 V)
. . . . .
Reservoir current (at 6.8 V) . . . . .
CX1599, page 2
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Min
Typical
Max
. –
0.2
0.3
kV
. –
0.03
–
ms
. –
5.0
–
ns
. –
0.2
1.0
ns
. . . . . . . . . . . . . .
see graph, page 4
. 9.5
10
10.5
A
. 1.0
1.5
2.0
A
# e2v technologies
NOTES
HEALTH AND SAFETY HAZARDS
1. Anode voltage must be command charged and applied for
510 ms. The tube will not operate with DC anode voltage.
2. This rate of rise refers to that part of the leading edge of
the pulse between 10% and 90% of the pulse amplitude.
3. The jitter levels and rate of rise of current specified in this
data sheet for fast rise time generator service can only be
obtained under very carefully controlled conditions. e2v
technologies therefore reserves the right to approve all
equipments in which the tube is used. DC heater power
supplies are needed to achieve the best jitter figures. If
jitter is not critical then an AC transformer can be used.
4. A recommended reservoir voltage is stamped on
each tube. For the fastest switching speed, the
reservoir voltage should be increased to a maximum
value consistent with anode voltage hold-off in the
equipment.
The reservoir heater supply must be obtained either from
the cathode heater supply or if a separate supply is used it
must be decoupled to avoid damage to the reservoir.
5. The tube must be mounted by means of its mounting
flange.
6. The peak inverse voltage including spike must not exceed
1.0 kV for the first 25 ms after the anode pulse.
7. For single-shot or low p.r.f. applications this parameter can
exceed 100 kA/ms. The ultimate value which can be
attained depends also to a large extent upon the external
circuit.
8. Measured with respect to cathode. When grid 1 is pulse
driven, at least the first 0.25 ms of the top of the grid 1
pulse must precede the delayed grid 2 pulse.
9. The tube may be operated with a loaded grid 2 bias voltage
of 0 to 725 V provided that care is taken to ensure that the
peak grid 1 drive current is sufficiently low to prevent triode
firing (tube control by the grid 1 pulse).
10. DC negative bias voltages must not be applied to grid 1.
When grid 1 is pulse driven, the potential of grid 1 may
vary between 710 and +5 V with respect to cathode
potential during the period between the completion of
recovery and the commencement of the succeeding grid
pulse.
11. The time interval between the instant when the unloaded
grid 2 voltage passes cathode potential and the instant
when anode conduction takes place.
12. The drift in delay time over a period from 10 seconds to
10 minutes of high voltage operation.
e2v technologies hydrogen thyratrons are safe to handle and
operate, provided that the relevant precautions stated herein
are observed. e2v technologies does not accept responsibility
for damage or injury resulting from the use of electronic devices
it produces. Equipment manufacturers and users must ensure
that adequate precautions are taken. Appropriate warning
labels and notices must be provided on equipments
incorporating e2v technologies devices and in operating
manuals.
# e2v technologies
High Voltage
Equipment must be designed so that personnel cannot come
into contact with high voltage circuits. All high voltage circuits
and terminals must be enclosed and fail-safe interlock switches
must be fitted to disconnect the primary power supply and
discharge all high voltage capacitors and other stored charges
before allowing access. Interlock switches must not be
bypassed to allow operation with access doors open.
X-Ray Radiation
All high voltage devices produce X-rays during operation and
may require shielding. The X-ray radiation from hydrogen
thyratrons is usually reduced to a safe level by enclosing the
equipment or shielding the thyratron with at least 1.6 mm
( 1/16 inch) thick steel panels.
Users and equipment manufacturers must check the radiation
level under their maximum operating conditions.
CX1599, page 3
MAXIMUM RECOVERY CHARACTERISTICS
40
2396B
PEAK ANODE CURRENT
300 A
RE-APPLIED ANODE VOLTAGE 1 kV
35
GRID 2 VOLTAGE 0 V
30
712.5
25
725
20
750
7100
MAXIMUM RECOVERY TIME (ms)
15
10
5
0
100
500
GRID 2 RECOVERY IMPEDANCE (O)
1000
5000
10 000
50 000
SCHEMATIC DIAGRAM
ANODE
VOLTAGE
8242
10 ms
MAX
ANODE
G2
CATHODE
HEATER
SUPPLY
RESERVOIR
HEATER
SUPPLY
G1
R2
R1
GRID 2 DELAYED
WITH RESPECT TO GRID 1
GRID 2 VOLTAGE
750 V, 0.5 ms
0
NEGATIVE BIAS VOLTAGE
GRID 1 CURRENT
30 A, 1 ms
C1
0.3 ms
GRID 1/GRID 2 DELAY
C2
(VARIABLE)
RECOMMENDED GRID, CATHODE AND RESERVOIR HEATER CONNECTIONS
R1
=
Grid 1 series resistor. 12 W vitreous enamelled wirewound is recommended, of a total impedance to set the grid 1
drive pulse circuit.
R2
=
Grid 2 series resistor. 12 W vitreous enamelled wirewound is recommended, of an impedance to match the grid 2
drive pulse circuit.
C1, C2 7
reservoir protection capacitors with a voltage rating 5500 V;
C1 =
1000 pF low inductance (e.g. ceramic),
C2 =
1 mF (e.g. polycarbonate or polypropylene).
Components R1, R2, C1 and C2 should be mounted as close to the tube as possible.
CX1599, page 4
# e2v technologies
OUTLINE
(All dimensions without limits are nominal)
1C
2395C
ANODE CONNECTION FITTED
WITH 8-32 UNC SCREW
SEE NOTE 4
E
A
GRID 1 CONNECTION
2 HOLES 1M
GRID 2 CONNECTION
2 HOLES 1L
P
F
G
MOUNTING FLANGE
SEE NOTE 1
1D
SEE NOTE 3
J
SEE NOTE 2
SEE NOTE 5
8 HOLES 1N
EQUISPACED ON H PCD
RESERVOIR HEATER LEAD (RED)
K LONG, TAG TO SUIT 1Q
1B
CATHODE HEATER LEAD (YELLOW)
K LONG, TAG TO SUIT 1Q
Ref
Millimetres
Inches
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
76.2 max
57.15
44.45 + 0.79
36.5
5.59 + 0.38
24.9
17.78
51.59 + 0.25
31.75 min
152.4
3.05
3.05
4.19
2.54
4.19
3.000 max
2.250
1.750 + 0.031
1.437
0.220 + 0.015
0.980
0.700
2.031 + 0.010
1.250 min
6.000
0.120
0.120
0.165
0.100
0.165
Inch dimensions have been derived from millimetres.
Outline Notes
1. The mounting flange is the connection for the
cathode, cathode heater return and reservoir
heater return.
2. A minimum clearance of 31.75 mm (1.250 inches)
must be allowed below the flange.
3. The recommended mounting hole is 38.1 mm
(1.500 inches) diameter.
4. The anode temperature is measured at the base
of the anode stem.
5. The base temperature is measured at this point.
Whilst e2v technologies has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use
thereof and also reserves the right to change the specification of goods without notice. e2v technologies accepts no liability beyond that set out in its standard
conditions of sale in respect of infringement of third party patents arising from the use of tubes or other devices in accordance with information contained herein.
# e2v technologies
Printed in England
CX1599, page 5