Proximity Sensors Inductive Thermoplastic Polyester Housing Type EIA 4025, 40 x 40 x 120 mm • Rotable-head, 5 positions • Mounting dimensions in accordance with DIN 43694 • Glass-reinforced thermoplastic polyester housing • Sensing distance: 25 mm • LED-indication for power and output ON • Fully protected • DC types 4-wire NO & NC, 10-55 VDC • AC/DC types 2-wire NO & NC, 20-250 VAC/DC Product Description Ordering Key Inductive proximity switch in standard limit switch housing. Rugged glass-reinforced polyester housing. Sensing face adjustable in up to 5 positions. 2-wire AC/DC for maximum efficiency. Type Housing type Rated operating dist.(mm) Output type Housing material Rated operating dist. (Sn) Ordering no. Transistor NPN Make & break switching Ordering no. Transistor PNP Make & break switching Ordering no. Power MOSFET Make & break switching 25 mm 1) EIA 4025 NPAP EIA 4025 PPAP EIA 4025 UPAP EIA 4025 PPA P Type Selection 1) 2) 2) For non-flush mounting Delivered: NO (make switching) Specifications Transistor NPN/PNP Power MOSFET output AC types Rated operational voltage (Ue) (UB) Ripple Rated operational current (Ie) Continuous 11.3 to 50 VDC 10 to 55 VDC (rippled included) ≤ 15% 24 to 230 VAC/VDC (VAC: 45 to 65 Hz) 20 to 250 VAC/VDC (VAC: 45 to 65 Hz) - ≤ 200 mA Short-time No-load supply current (Io) Minimum load current OFF-state current (Ir) (leakage) ≤ 25 mA 50 µA Voltage drop (Ud) 0.8 to 3.5 V Protection Power ON delay Frequency of operating cycles (f) Indication for supply ON (LED 2) Indication for output ON (LED 1) Rated operating dist. (Sn) Repeat accuracy (R) Reverse polarity, short-circuit ≤ 100 ms ≤ 100 Hz LED, green LED, yellow 25 mm ≤ 5% 5 - 250 mA @ 25°C 5 - 180 mA @ 70°C ≤ 2 A, t ≤ 20 ms (Max. 1 pulse per s) 5 mA ≤ 1.7 mA @ 120 VAC ≤ 2.5 mA @ 220 VAC Static: ≤ 10.5 V Dynamic: ≤ 7.5 V Transient voltages, short-circuit ≥ 200 ms ≤ 100 Hz LED, yellow 25 mm ≤ 5% Specifications are subject to change without notice (20.08.01) 1 EIA 4025, 40 x 40 x 120 mm Specifications (cont.) Hysteresis (H) (Differential travel) Effective operating dist. (Sr) Usable operating dist. (Su) Ambient temperature Operating Storage Degree of protection Shock resistance Vibration resistance Housing material Terminal block Cable gland Weight CE-marking Transistor NPN/PNP Power MOSFET output AC types 3 to 20% of sensing distance 0.9 x Sn ≤ Sr ≤ 1.1 x Sn 0.9 x Sr ≤ Su ≤ 1.1 x Sr 3 to 20% of sensing distance 0.9 x Sn ≤ Sr ≤ 1.1 x Sn 0.9 x Sr ≤ Su ≤ 1.1 x Sr -25° to +70°C (-13° to +158°F) -30° to +80°C (-22° to +176°F) IP 67 (Nema 1, 3, 4, 6, 13) 30 G/ 11 ms 10 to 50 Hz/1 mm/5 min. PBTP 4 terminals for 2 x 2.5 mm2 wires, self-lifting M20 x 1.5 200 g Yes -25° to +70°C (-13° to +158°F) -30° to +80°C (-22° to +176°F) IP 67 (Nema 1, 3, 4, 6, 13) 30 G/ 11 ms 10 to 50 Hz/1 mm/5 min. PBTP 2 terminals for 2 x 2.5 mm2 wires, self-lifting M20 x 1.5 200 g Yes Wiring Diagrams Dimensions 40 5.3 1 4 7.3 30 2 40 Sensing surface 3 EIA 4025 NPAP 7.3 46 LED1 LED2 60 6.5 120 1 4 2 3 EIA 4025 PPAP Internal programmable EIA 4025 UPAP 2 Specifications are subject to change without notice (20.08.01) EIA 4025, 40 x 40 x 120 mm Installation Hints Table 1 Installation examples Sensing surface on head ("top"); other orientations of the sensing surface mean deviations from nominal sensing distance. Figure 1 a (mm) ≥ 40 Sn (mm) ≤ 20 Figure 2 a (mm) ≥ 40 Sn (mm) ≤ 25 Figure 3 Flush mounting not permitted a a a Table 2 Adjacent mounting To avoid cross-interference when mounting the sensors next to each other, the given separations (a) should be maintained. Figure 4 a (mm) ≥ 120 a a Specifications are subject to change without notice (20.08.01) 3