ETC JQX-115F

JQX-115F-I
MINIATURE HIGH POWER RELAY
Features
* High Inrush TV-5 80A /125VAC
File No.:116934
* Low height 15.7 mm
* 5KV dielectric coil to contacts
* Creepage distance 10mm
* Sealed IP67& Flux proof types available
File No.:CQC02001001951
* VDE0860
CONTACT DATA
COIL
Contact Arrangement
1A
Initial Contact Resistance Max.
0.4W
Coil power
50m (at 1A/ 6VDC)
Contact Material
AgSnO2
Max. switching voltage
440VAC/ 125VDC
Max. switching current
16A
General Purpose Power Relays JQX-115F-I
Max. switching power
4000VA
16A 250VAC
COIL DATA
Nominal
Voltage
VDC
Pick-up
Voltage
VDC
Max.
Coil
Drop-out allowable
Resistance
Voltage
Voltage
VDC VDC(at 20 ) (20 )
5
3.50
0.5
6
4.20
0.6
(2.5 x 104 ops)
9
6.30
0.9
Mechanical life
2 x 106 OPS
12
8.40
1.2
Electrical life
1 x 105 OPS
18
12.6
24
Contact Rating
(3 x 10
4
TV-5, 80A
Inrush Rating
@ 125VAC
62
10%
90
10%
203
10%
18
360
10%
1.8
27
810
10%
16.8
2.4
36
1440
10%
48
33.6
4.8
72
5760
15%
60
42.0
6.0
90
7500
15%
110
77.0
11.0
165
25200
15%
7.5
360 ops/hour)
9.0
13.5
*Note: The AgSnO2 material is with indium
CHARACTERISTICS
Initial Insulation Resistance
1000M 500 VDC
Dielectric Between coil and Contacts
5000VAC 1min.
Strength
1000VAC 1min.
Between open contacts
Surge voltage between coil and contacts
10KV (1.2X50µs)
Operate time (at nomi. Volt.)
Max. 15ms
Release time (at nomi. Volt.)
Max. 8ms
Temperature rise (at nomi. Volt.)
Max. 55
SAFETY APPROVAL RATINGS
JQX-115F-I (High Inrush)
Shock Resistance
Functional
100 m/s2
Destructive
1000 m/s2
Vibration Resistance
Humidity
Ratings
1H(S)3A(G)(F)
16A/ 250VAC @85°C
10 to 150Hz, 20g
35% to 85%
Ambient temperature
-40
to +85
Termination
PCB
Unit weight
13.5g
Construction
Sealed IP67
& Flux proof
HONGFA RELAY
ISO9001*ISO/TS16949 *ISO14001 CERTIFIED
90
Specifications
VDE
VERSION: EN02-20040601
ORDERING INFORMATION
JQX-115F-I /
012
1H
S
3
A
Type
Coil voltage
5, 6, 9,12, 18, 24, 48, 60, 110VDC
Contact arrangement
1H: 1 Form A
Structure
S: Sealed IP67
Version
3: 5.0mm
Contact Material
Nil: Flux proof
A: AgSnO2 (with indium)
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Outline Dimensions
General Purpose Power Relays JQX-115F-I
PCB layout
5mm 1 Form A
Wiring Diagram
5.04
20.16
5mm 1 Form A
CHARACTERISTICS CURVE
COIL OPERATING RANGE (DC)
LIFE CURVE
3.6
1000
Coil Voltage(U/UN)
Operations (X10000 OPS)
3.4
100
10
3.0
2.6
2.2
1.8
16 A
1.4
1.0
0.6
1
0
2
4
6
8
10
12
14
Contact Current (A)
16
18
20
0
+20
+40
+60
+80
Ambient Temperature(
+100
)
91