ETC MGDBI-10-I-E

Industrial DC/DC CONVERTER
MGDI-10 Standard Input : 10W POWER
Industrial
Grade
2:1 Standard Input
Single & Bi Outputs
Metallic case - 1.500 VDC Isolation
• Low profile : 0,33 “ ( 8.5mm)
• Nominal power of 10 W without derating
• Wide temperature range : -40°C/+95°C case
• High efficiency up to 83 %
• Soft start
• Galvanic isolation 1.500 VDC
• Integrated LC EMI filter
• Permanent short circuit protection
• No optocoupler for high reliability
1-General
The MGDI-10 series is a full family of DC/DC
power modules designed for use in distributed
power architecture and are particularly suitable
for mobile or ground fixed applications in
transportation, industry and télécommunication
areas. These modules use a high frequency fixed
switching technic at 480 KHz providing excellent
reliability, low noise characteristics, high power
density and a low profile package. Standard
models are available with nominal input voltages as 5, 12, or 24 volts in range of 4,5-5,5 or
18-36 volts. The series include single and bi
output voltage choices of 3,3, 5, 12, 15, +/-5,
+/-12 or +/-15 volts.
No external heatsink is required for the MGDI10 series to supply 10W output power over the
case temperature range of -40°C up to 95°C.
The MGDI-10 series is designed in conformity
with safety standards EN60950 and UL1950.
All the modules are designed with LC network
filters to minimize reflected input current ripple
and output voltage ripple according to EN55022
and FCC Part 15J standard.
The modules include a soft-start, an input
undervoltage lock-out, a permanent short circuit protection and an output overvoltage protection to ensure efficient module protections.
The soft-start allows current limitation and
eliminates inrush current during start-up. The
short circuit protection completely protects the
modules against short-circuits of any duration
by a shut-down and restores to normal when
the overload is removed.
The design has been carried out with surface
mount components and is manufactured in a
fully automated process to guarantee high
quality. Each module is tested and burned in
with a GAIA Converter automated test
equipment.
2-Product Selection
Single output model
: MGDSI-10-
Bi output model
: MGDBI-10-
Input Voltage Range
Output
Permanent
B : 3.3 VDC
C : 5 VDC or +/-5VDC
E : 12 VDC or +/-12VDC
F : 15 VDC or +/-15VDC
C : 4,5-5,5 VDC
I : 18-36 VDC
REDEFINING THE SOURCE OF POWER
© Gaia Converter FC97-006.03/06 Revision M
For locations, phone, fax, E-Mail see back cover
5
Industrial
Grade
MGDI-10 Standard Input Series
2- Product Selection (continued)
Input range
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
18-36
18-36
18-36
18-36
18-36
18-36
18-36
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
Output
Current
Reference
Options
3,3 VDC
5 VDC
12 VDC
15 VDC
+/- 5 VDC
+/- 12 VDC
+/- 15 VDC
2A
2A
0,80 A
0,65 A
+/- 1 A
+/- 0,40 A
+/- 0,33 A
MGDSI-10-C-B
MGDSI-10-C-C
MGDSI-10-C-E
MGDSI-10-C-F
MGDBI-10-C-C
MGDBI-10-C-E
MGDBI-10-C-F
/
/
/
/
/
/
/
3,3 VDC
5 VDC
12 VDC
15 VDC
+/- 5 VDC
+/- 12 VDC
+/- 15 VDC
2A
2A
0.80 A
0.65 A
+/- 1 A
+/- 0.40 A
+/- 0.33 A
MGDSI-10-I-B
MGDSI-10-I-C
MGDSI-10-I-E
MGDSI-10-I-F
MGDBI-10-I-C
MGDBI-10-I-E
MGDBI-10-I-F
/
/
/
/
/
/
/
Converter Selection Chart
5
M G D S I - 10 - I - C
Number of Outputs :
S : single output
B : bi output
Input voltage range :
C : 4.5-5.5 VDC
I : 18-36VDC
Output voltage :
See table page 1
© Gaia Converter FC97-006.03/06 Revision M
2
For locations, phone, fax, E-Mail see back cover
MGDI-10 Standard Input Series
Industrial
Grade
3- Electrical Specifications
Data are valid at +25°C, unless otherwise specified.
Parameter
Input
Nominal input voltage
Permanent input
voltage range (Ui)
Undervoltage lock-out
(UVLO)
Start up time
Reflected ripple current
Input current in short
circuit mode (Average)
No load input current
Conditions
Limit or
typical
Units
Full temperature range
Nominal
Full temperature range
turn-on/turn-off threshold
Single Output MGDSI- 10
10 - C
10 - I
VDC
5
24
Min. - Max.
VDC
4,5- 5,5
18- 36
Minimum
Maximum
VDC
VDC
4
4,5
16
17,5
Maximum
ms
30
30
Maximum
mApp
50
30
Maximum
mA
50
30
Maximum
mA
50
30
Nominal
Nominal
Nominal
Nominal
VDC
VDC
VDC
VDC
3,3
5
12
15
3,3
5
12
15
Maximum
%
+/- 2
+/- 2
Maximum
W
10
10
Full temperature range
Ui min. to max.
Maximum
Maximum
Maximum
Maximum
A
A
A
A
2
2
0,80
0,65
2
2
0,80
0,65
Ui nominal
Full load
BW = 20MHz
Maximum
Maximum
Maximum
mVpp
mVpp
mVpp
50
100
150
50
100
150
Maximum
%
+/- 1
+/- 1
Maximum
%
+/- 2,5
+/- 2,5
Typical
%
77
83
Maximum
Maximum
µF
µF
1.000
330
1.000
330
Ui nominal
Nominal output
Full load : resistive
Ui nominal, full load at switching freq. BW =
20MHz
Decoupling capacitor 10µF
Ui nominal
Short-circuit
Ui nominal
No load
Output
Output voltage *
Set Point accuracy
Output power
Output current
3,3V output
5V output
12V output
15V output
Ripple output voltage **
3,3V and 5V output
12V output
15V output
Line regulation
Load regulation ***
Efficiency
Maximum admissible
Capacity load
3,3V and 5V output
12V and 15V output
Full temperature range
Ui min. to max.
75% load
Ambient temperature : +25°c
Ui nominal, 75% load
Full temperature range
Ui min. to max.
Ui min. to max.
Full load
Ui nominal
25% to full load
Ui nominal
Full load
Ui nominal
Full load
Per output
5
Note * : For proper operation the MGDI-10 module requires to install a 22µF chemical or tantalum capacitance accross output terminals.
Note ** : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered.
This noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the
pin Gout of the converter. This capacitor should be layed-out as close as possible from the converter.
Note *** : For load regulation characteristics from 0% to full load, please contact factory.
© Gaia Converter FC97-006.03/06 Revision M
3
For locations, phone, fax, E-Mail see back cover
MGDI-10 Standard Input Series
Industrial
Grade
3- Electrical Specifications (continued)
Data are valid at +25°C, unless otherwise specified.
Parameter
Input
Nominal input voltage
Permanent input
voltage range (Ui)
Undervoltage lock-out
(UVLO)
Start up time
Reflected ripple current
Input current in short
circuit mode (Average)
No load input current
Conditions
Limit or
typical
Units
Full temperature range
Nominal
Full temperature range
turn-on/turn-off threshold
Bi Output MGDBI- 10
10 - C
10 - I
VDC
5
24
Min. - Max.
VDC
4,5- 5,5
18- 36
Minimum
Maximum
VDC
VDC
4
4,5
16
17,5
Maximum
ms
30
30
Maximum
mApp
50
30
Maximum
mA
50
30
Maximum
mA
50
30
Nominal
Nominal
Nominal
VDC
VDC
VDC
+/- 5
+/- 12
+/- 15
+/- 5
+/- 12
+/- 15
Maximum
%
+/- 2
+/- 2
Maximum
W
+/- 5
+/- 5
Full temperature range
Ui min. to max.
Maximum
Maximum
Maximum
A
A
A
+/- 1
+/- 0,40
+/- 0,33
+/- 1
+/- 0,40
+/- 0,33
Ui nominal
Full load
BW = 20MHz
Maximum
Maximum
Maximum
mVpp
mVpp
mVpp
50
100
150
50
100
150
Maximum
%
+/- 1
+/- 1
Maximum
%
+/- 2,5
+/- 2,5
Maximum
%
+/- 0,5
+/- 0,5
Typical
%
77
83
Maximum
Maximum
µF
µF
470
100
470
100
Ui nominal
Nominal output
Full load : resistive
Ui nominal, full load at switching freq. BW =
20MHz
Decoupling capacitor 10µF
Ui nominal
Short-circuit
Ui nominal
No load
Output
Output voltage *
Set Point accuracy
Output power
Output current
+/- 5V output
+/- 12V output
+/- 15V output
Ripple output voltage **
5V output
12V output
15V output
Line regulation
Load regulation ***
Cross load output
regulation
Efficiency
Maximum admissible
Capacity load
3,3V and 5V output
12V and 15V output
Full temperature range
Ui min. to max.
75% load
Ambient temperature : +25°c
Ui nominal, 75% load
Full temperature range
Ui min. to max.
Ui min. to max.
Full load
Ui nominal
25% to full load
Ui nominal
+ Vout nominal load
- Vout from 25% to full load
Ui nominal
Full load
Ui nominal
Full load
Per output
5
Note * : For proper operation the MGDI-10 module requires to install a 22µF chemical or tantalum capacitance accross output terminals.
Note ** : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered.
This noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the
pin Gout of the converter. This capacitance should be layed-out as close as possible from the converter.
Note *** : For load regulation characteristics from 0% to full load, please contact factory.
© Gaia Converter FC97-006.03/06 Revision M
4
For locations, phone, fax, E-Mail see back cover
Industrial
Grade
MGDI-10 Standard Input Series
4- Switching Frequency
Parameter
Conditions
Limit or typical
Specifications
Switching frequency
Full temperature range
Ui min. to max.
No load to full load
Nominal, fixed
480 KHz
Parameter
Conditions
Limit or typical
Specifications
Electric strength test voltage
Input to output
Minimum
1.500 VDC / 1 min
Electric strength test voltage between
outputs (for dual and triple outputs)
Output to output
Minimum
No isolation
Isolation resistance
500 VDC
Minimum
100 MOhm
5- Isolation
6- Protection Functions
Characteristics
Protection Device
Recovery
Limit or typical
Specifications
Input undervoltage lock-out (UVLO)
Turn-on, turn-off circuit
with no hysteresis
Automatic
recovery
Threshold
See section 3
Output short circuit protection (SCP)
Hiccup circuitry with
auto-recovery
Automatic
recovery
Permanent
See section 11
/
Maximum
Maximum
Maximum
Maximum
For 3.3v : 4v
For 5v : 6v
For 12v : 14v
For 15v : 17v
Output overvoltage protection (OVP)
Zener clamp
5
7- Reliability Data
Characteristics
Conditions
Temperature
Specifications
Ground fixed (Gf)
Case at 40°C
Case at 70°C
950.000 Hrs
380.000 Hrs
Ground mobile (Gm)
Case at 40°C
Case at 70°C
240.000 Hrs
105.000 Hrs
Mean Time Between Failure (MTBF)
According to MIL-HDBK-217F
Mean Time Between Failure (MTBF)
According to IEC-62380-TR
© Gaia Converter FC97-006.03/06 Revision M
Telecom switchers
/
Consult factory
5
For locations, phone, fax, E-Mail see back cover
Industrial
Grade
MGDI-10 Standard Input Series
8- Electromagnetic Interference
Electromagnetic interference requirements according to EN55022 class A and class B can be easily achieved as
indicated in the following table :
Electromagnetic Interference according to EN55022
Configuration
Conducted noise
emission
With common mode capacitor
C c = 10nF and input capacitor C
Models
With common mode capacitor
C C = 10nF and external filter
4,5-5,5V input models
Class A, C i =10µF/ 35 V tantalum
Class B
18-36V input models
Class A, C i =4.7µF / 50 V tantalum
Class B
Configuration
Radiated noise
emission
i
With common mode capacitor C c = 10 nF
Models
All models
Class B
8-1 Module Compliance with EN55022 class A Standard
Electromagnetic interference requirements according
to EN55022 class A can be easily achieved by adding
an external input capacitance (CI Value explained in
previous table) and a common mode noise capacitance
Cc (10 nF/rated voltage depending on isolation
requirement) connected between Gin and Gout. This
common mode noise capacitance Cc should be layedout as close as possible from the DC/DC converter.
+ Input
Vi
Input capacitance C i
Vo
MGDI - Series
5
Go
Gi
- Input
Common mode noise capacitance C c = 10nF
8-2 Module Compliance with EN 55022 Class B Standard
Electromagnetic interference requirements according to
EN55022 class B can be easily achieved by adding an
external input filter consisting of 4 capacitances, a
common mode choke, and a differential
L1
L2
mode inductance, together with a common mode noise
capacitance (10 nF/rated voltage depending on isolation requirement) connected between Gin and Gout.
Please consult EN55022 Class B EMI Filter design dote
for further details.
C3
Vi
+ Input
C1
C2
- Input
Vo
MGDI - Series
Gi
Go
C4
Common mode noise capacitance C c = 10nF
© Gaia Converter FC97-006.03/06 Revision M
6
For locations, phone, fax, E-Mail see back cover
MGDI-10 Standard Input Series
Industrial
Grade
9- Thermal Characteristics
Characteristics
Conditions
Limit or typical
Performances
Operating ambient temperature
range at full load
Ambient temperature *
Minimum
Maximum
- 40°C
+ 71°C
Operating case temperature
range at full load
Case temperature
Minimum
Maximum
- 40°C
+95°C
Storage temperature range
Non functionning
Minimum
Maximum
- 40°C
+ 105°C
Thermal resistance
Rth case to ambient in free air
natural convection
Typical
12°C /W
Note * : The upper temperature range depends on configuration, the user must assure a max. case temperature of + 95°C.
The MGDI-10 series operating case temperature must not exceed 95°C. The maximum ambient temperature admissible for
the DC/DC converter corresponding to the maximum operating case temperature of 95°C depends on the ambient airflow,
the mounting/orientation, the cooling features and the power dissipated.
To calculate a maximum admissible ambient temperature the following method can be used. Knowing the maximum case
temparature Tcase = 95°C of the module, the power used Pout and the efficiency η :
• determine the power dissipated by the module Pdiss that should be evacuated :
η - 1)
Pdiss = Pout(1/η
• determine the maximum ambient temperature :
Ta = 95°C - Rth x Pdiss
where Rth is the thermal resistance from the case to ambient.
The previous thermal calculation shows two areas of operation :
• a normal operation area in a free natural ambient convection (grey area in this following graph),
• an area with cooling features (air flow or heatsink) ensuring a maximum case temperature below the maximum
operating case temperature of 95°C (white area in the following graph).
5
Power (W)
100%
Additionnal cooling operation area
75%
Natural convection operation area
50%
25%
10
20
30
40
50
60
70
80
90
100
Temperature (˚C)
Full load ambient temperature without derating : 71˚C
Maximum case temperature : 95˚C
Maximum storage temperature : 105˚C
© Gaia Converter FC97-006.03/06 Revision M
7
For locations, phone, fax, E-Mail see back cover
MGDI-10 Standard Input Series
Industrial
Grade
10- Environmental Qualifications
The modules have been subjected to the following environmental qualifications.
Characteristics
Conditions
Severity
Test procedure
Climatic Qualifications
Life at high
temperature
Duration
Temperature
Status of unit
1.000 Hrs
95°C case
unit operating
IEC 68-2-2
Humidity steady
Damp heat
Temperature
Duration
Status of unit
93 % relative humidity
40°C
56 days
unit not operating
IEC 68-2-3
Test Ca
Temperature
cycling
Number of cycles
Temperature change
Transfert time
Steady state time
Status of unit
200
-40°C / +71°C
40 min.
20 min.
unit not operating
IEC 68-2-14
Test N
Temperature
shock
Number of shocks
Temperature change
Transfert time
Steady state time
Status of unit
50
-40°C / +105°C
10 sec.
20 min.
unit not operating
IEC 68-2-14
Test Na
Mechanical Qualifications
Vibration
(Sinusoidal)
Number of cycles
Frequency : amplitude
Frequency : acceleration
Amplitude /acceleration
Duration
Status of unit
10 cycles in each axis
10 to 60 Hz / 0.7 mm
60 to 2000 Hz / 10 g
0.7 mm/10 g
2h 30 min. per axis
unit not operating
Shock
(Half sinus)
Number of shocks
Peak acceleration
Duration
Shock form
Status of unit
3 shocks in each axis
100 g
6 ms
1/2 sinusoidal
unit not operating
IEC 68-2-27
Test Ea
Bump
(Half sinus)
Number of bumps
Peak acceleration
Duration
Status of unit
2000 bumps in each axis
25 g
6 ms
unit not operating
IEC 68-2-29
Test Eb
IEC 68-2-6
Test Fc
5
Electrical Immunity Qualifications
Electrical
discharge
susceptibility
Number of discharges
Air discharge level
Contact discharge level
Air discharge level
Contact discharge level
10 positive & 10 negative discharges
4 kV : sanction A
2 Kk : sanction A
8 Kk : sanction B
4 kV : sanction B
EN55082-2 with :
EN61000-4-2
IEC 801-2
Electrical field
susceptibility
Antenna position
Electromagnetic field
Wave form signal
Frequency range
at 1 m
10 V/m
AM 80%, 1 kHz
26 MHz to 1 GHz
EN55082-2 with :
EN61000-4-3
IEC801-3
Electrical fast
transient
susceptibility
Burst form
Wave form signal
Impedance
Level 1
Level 3
5/50 ns
5 kHz with 15 ms burst duration period 300 ms
50 Ohm
0,5 kV : sanction A
2 kV : sanction B
EN55082-2 with :
EN61000-4-4
IEC801-4
© Gaia Converter FC97-006.03/06 Revision M
8
For locations, phone, fax, E-Mail see back cover
Industrial
Grade
MGDI-10 Standard Input Series
11- Description of Protections
11-1 Input Undervoltage Lock-out (UVLO)
The input undervoltage lock-out protection device turnson and turns-off the output voltage when the input bus
voltage reaches the undervoltage lock-out threshold. There
is no hysteresis cycle at turn-on and turn-off.
On
Off
UVLO
Turn-on/Turn-off
11-2 Output Short Circuit Protection (SCP)
The short circuit protection device protects the module
against short circuit of any duration and restores the module to normal operation when the short circuit is removed.
It operates in «hiccup» mode by testing periodically if an
overload is applied (typically every 200ms recovery time).
The overload detection threshold is typically 200% of maximum current with a detection time lower than 5ms.
Vin
Vo (%)
100
detection time
x
time
recovery time
recovery time
11-3 Output Overvoltage Protection (OVP)
The output overvoltage protection device protects external
components against high voltage or possible overvoltages
which can be supplied by the module (i.e in case of internal
failure). It consists of a zener diode clamping the output
voltage; under worst case conditions this zener diode will
short-circuit.
The output voltage protection is not designed to withstand
externally applied output overvoltages to protect the module itself.
© Gaia Converter FC97-006.03/06 Revision M
5
9
For locations, phone, fax, E-Mail see back cover
MGDI-10 Standard Input Series
Industrial
Grade
12- Application Notes
12-1 Connection of Outputs in Series
Any of the bi output converters can be configured to produce
an output of 10V (+/-5 output models), 24V (+/-12V output models), or 30V (+/-15V output models) by connecting
the load across the output (+) and the output (-) with
either output grounded, and leaving the common pin
floating.
VI
+Vo
Go
GI
-Vo
VI
Vo
GI
Go
2 x Vo
12-2 Connection of Modules in Series
The output of single output units can be connected in
series without any precautions to provide higher output
voltage level.
Nevertheless, GAIA Converter recommends to protect each
individual output by a low power shottky diode rated with
the maximum current of the converter to avoid reverse
polarity at any output.
Reverse polarity may occur at start up if the output voltages do not rise at the same time.
2 x Vo
VI
Vo
GI
Go
5
12-3 Connection of Modules in Parallel
Several converters with equal output voltage can be
connected in parallel to increase power. Nevertheless some
cares have to be taken in particular as the output voltage
of each converter is slightly different, when paralleling,
the converter with the highest output voltage will source
the most current.
However the GAIA Converter modules are designed with a
“soft’’ output voltage versus current characteristic. This
causes the output voltage of each converter to automatically
adjust downward as its current increases so each converter
very approximately shares the total output current. It is
important that each converter has approximately the same
impedance between their output and the common load.
© Gaia Converter FC97-006.03/06 Revision M
VI
Vo
Vo
GI
Go
VI
Vo
GI
Go
10
For locations, phone, fax, E-Mail see back cover
MGDI-10 Standard Input Series
Industrial
Grade
13- Dimensions
Dimensions are given in mm (inches). Tolerance : +/- 0,2 mm (+/- 0.01 “) unless otherwise indicated.
Weight : 20 grams (0.7 Ozs) max.
40
26
(1.58")
(1.03")
7,60
8
(0.30")
(0.32")
5 min
(0.20")
26,20
10,16
(1.03")
(0.40")
20,32
35.56
(0.80")
(1,40")
Pin dimensions : O 0,73 mm (0.03 ”)
Metallic case black anodized coating
Matte tin plating finished pin
14- Product Marking
Upper face : Company logo, location of manufacturing.
Side face : Module reference, option, date code : year and week of manufacturing.
5
15- Connections
4
5
1
2
6
Pin
Bi Output
Single Output
1
+ Input (Vi)
+ Input (Vi)
2
No pin
No pin
3
- Input (Gi)
- Input (Gi)
4
Output + (+Vo)
Output (Vo)
5
Common (Go)
No pin
6
Output - (-Vo)
Common (Go)
3
Bottom view
© Gaia Converter FC97-006.03/06 Revision M
11
For locations, phone, fax, E-Mail see back cover
International Headquarters
Marketing and Sales department
GAÏA Converter - France
Address : B.P. 14 - MERIGNAC - FRANCE
Tel. : + (33)-5-57-92-12-80
Fax : + (33)-5-57-92-12-89
North American Headquarters
GAÏA Converter Canada, Inc
Address : 6611 Thimens
ST-LAURENT, QUEBEC - CANADA H4S 1W2
Tel. : (514)-333-3169
Fax : (514)-333-4519
Represented by :
Information given in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed for the consequence of its use nor for any infringement of patents or other rights of third parties which may result from its use.
These products are sold only according to GAIA Converter general conditions of sale, unless otherwise confirmed by writing. Specifications subject to change without notice.
Printed in France by GAIA Converter FC97-004.03/06 Revision M Graphisme : Philippe Clicq
For more detailed specifications and applications information, contact :