140 MHz Filter 18 MHz Bandwidth Part Number SF0140BA03073S Micro Networks, 324 Clark Street, Worcester, MA 01606, USA tel: 508-852-5400, fax:508-852-8456, www.micronetworks.com TYPICAL PERFORMANCE Horizontal: 6 MHz/div Vertical (from top): Magnitude 10,1 dB/div Phase Deviation 10 deg/div Group Delay Variation 100 ns/div SPECIFICATION Parameter Center Frequency (Fc) 1 Insertion Loss 1 dB Bandwidth 3 dB Bandwidth 30 dB Bandwidth 40 dB Bandwidth Passband Ripple Phase Deviation from Linear2 Group Delay Variation2 Absolute Delay Substrate Temperature Coefficient of Frequency (Tc)3 Ambient Temperature System Source and Load Impedance Notes: Min 139.6 17.25 18 Typ 140 10 18.2 19.2 22.2 34 0.7 5 85 0.82 LiNbO3 -90 25 50 Max 140.4 12 23 48 1 10 120 Units MHz dB MHz MHz MHz MHz dB deg ns µs ppm/°C °C Ω 1. Average of lower & upper 3 dB frequencies. 2. Evaluated over 80% of the 3 dB bandwidth. 3. Typical change of filter frequency response with temperature is ∆f/fref = (T-Tref)*Tc ppm. Rev X3 17-Nov-03 Page 1 of 2 140 MHz Filter 18 MHz Bandwidth Part Number SF0140BA03073S Micro Networks, 324 Clark Street, Worcester, MA 01606, USA tel: 508-852-5400, fax:508-852-8456, www.micronetworks.com PACKAGE OUTLINE Units: mm Pin Configuration: Input: 11 Input Return: 12 Output: 5 Output Return: 6 Ground: 1,2,3,4,7,8,9,10 MATCHING CIRCUIT Component values in 50 Ω: (Minimum Q = 40) Ls1 = 120 nH Cp1 = 22 pF 11 5 12 6 Ls2 = 120 nH Cp2 = 10 pF Notes • Optimum component values may change depending on board layout. The values shown here are intended as a guide only. ISO 9001 Registered Micro Networks 324 Clark Street Worcester, MA 01606. tel: 508-852-5400 fax: 508-852-8456 www.micronetworks.com Rev X3 17-Nov-03 Page 2 of 2