INTERPOINT HR301-2805

FEATURES
DC/DC CONVERTERS
28 VOLT INPUT
• –40° to +85°C operation
• 18 to 36 VDC input
(19 to 36 VDC input HR301-2805)
• Fully Isolated
• Optocoupler feedback
• Fixed frequency, 240 to 300 kHz typical
• Topology – Push-Pull Forward
• 50 V for up to 50 ms transient protection
• Inhibit function
• Indefinite short circuit protection
• Remote sense on HR301-2805 model
• Up to 86% efficiency
HR300 SERIES
30 WATT
MODELS
VDC OUTPUT
SINGLE
5
12
15
DUAL
±12
±15
Size (max.): 2.720 x 1.350 x 0.505 inches (69.09 x 34.29 x 12.83 mm)
See Section B8, case J5, for dimensions.
Weight:
60 grams max.
Screening: Standard only. See Section C2 for screening description.
DESCRIPTION
HR300 Series™ DC/DC converters combine the small size and high
reliability of hybrid-based components, the high efficiency of
switching regulators, and the isolation, regulation, and low noise
characteristics of linear regulators.
SMALL SIZE AND RELIABILITY
HR300 DC/DC converters use thick-film hybrid manufacturing techniques for smaller size, lighter weight and higher reliability than
converters produced with other circuit techniques. With a footprint of
less than 3.7 square inches and a 0.5 inch height, the HR300
converters reach power densities up to 22 watts per cubic inch.
The HR300 parts use the same manufacturing procedures and
quality controls that Interpoint applies to converters built for aerospace and military applications. The converters are hermetically
sealed in metal packages that are guaranteed a maximum leak rate
of less than 10-3 atm-cc/sec.
HIGH PERFORMANCE
HR300 converters use a constant frequency pulse-width modulated
switching regulator design operating in the forward mode with a
clock switching frequency of 240 to 300 kHz. Isolation is achieved
through the use of a transformer in the forward power circuit and an
optocoupler in the feedback control loop. The full load output power
of 30 watts is available over the entire 18 to 36 VDC input range (19
to 36 HR301-2805). On dual output models, up to 90% of full power
is available from either output up to a combined total of 30 watts.
The HR300’s high efficiency is maintained over the entire input
voltage range and from approximately 25% of full load to full load
(see typical efficiency curves).
Short circuit protection is provided through foldback current limiting.
When the output current reaches approximately 125% of the full
rated load, the output voltage begins to reduce to protect the
converter. The converter can sustain a true short circuit condition
indefinitely. The HR300’s flanged case facilitates removal of heat
and provides for mechanically secure mounting. If full power operation or indefinite short circuit protection is a system requirement, the
HR300 converter should be mounted with an efficient heat sink in
contact with the mounting flange.
Internal filters in all HR300 converters provide low noise on both
the input and outputs. On HR301 models, two-section
L-C filters limit output ripple voltage and reflected input ripple
current. On HR302 models, single-section L-C filters perform the
same function.
For maximum output regulation, the HR301-2805 is provided with
external output voltage remote sense pins. Connecting the remote
sense pins to the load provides a four-terminal voltage mode which
eliminates the adverse effects of line resistance voltage drops.
Remote sense pins may be left unconnected, but see cautions in
this data sheet. For normal operation, remote sense pins should be
connected to the respective output pins.
INHIBIT FUNCTION
An inhibit is provided to allow a logic input to shut down the
converter. An open circuit on the inhibit pin (pin 2 or 8) allows normal
operation. A connection between the inhibit pin and the input
common (pin 10) disables the internal oscillator, shutting down the
output. The inhibit pin has an open circuit voltage of 11 to 16 V on
single output models, 8 to 12 V on HR302-2812 and 10 to 14 V on
HR302-2815. In the inhibit mode, approximately 1 mA must be sunk
from the inhibit pin. An active low open collector is required to activate the inhibit function.
B4-39
HR300 SERIES
30 WATT
DC/DC CONVERTERS
INHIBIT
TYPICAL CHARACTERISTICS
Inhibit TTL Open Collector
• Logic low (output disabled)
Inhibit pin current 1 mA typical
• Referenced to input common
• Logic high (output enabled)
Open collector
Output Voltage Temperature Coefficient
• 100 ppm/°C typical
Input to Output Capacitance
• 80 pF typical single output models
• 70 pF typical HR302-2812
• 60 pF typical HR302-2815
Current Limit
• 125% of full load, typical
Isolation
• 100 megohm minimum at 500 V
Conversion Frequency
• 240 to 300 kHz
Inhibit Pin Voltage (unit enabled)
• 11 to 16 V single output models
• 8 to 12 V HR302-2812
• 10 to 14 V HR302-2815
ABSOLUTE MAXIMUM RATINGS
Input Voltage
• 18 to 36 VDC (19 to 36 VDC HR301-2805)
Output Power
• 30 watts
Lead Soldering Temperature (10 sec per lead)
• 300°C
Storage Temperature Range (Case)
• –55°C to +125°C
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
• 18 to 36 VDC continuous
19 to 36 VDC HR301-2805
• 50 V for 50 msec transient
Case Operating Temperature (Tc)
• –40°C to +85°C full power
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
SINGLE OUTPUT MODELS
PARAMETER
HR301-2805
HR301-2812
HR301-2815
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
UNITS
OUTPUT VOLTAGE
4.95
5.0
5.05
11.88
12
12.12
14.85
15
15.15
VDC
OUTPUT CURRENT
—
—
6.0
—
—
2.5
—
—
2.0
A
—
—
30.0
—
—
30.0
—
—
30.0
W
OUTPUT POWER
CONDITIONS
–40°C TO +85°C
BW ≤ 2 MHz
—
30
60
—
30
70
—
30
75
mV p-p
LINE REGULATION1
MIN. TO MAX. VIN
—
7
25
—
10
40
—
10
40
mV
LOAD REGULATION2
NO LOAD TO FULL
—
5
25
—
10
40
—
10
40
INPUT VOLTAGE
NO LOAD TO FULL
19
28
36
18
28
36
18
28
36
–40°C TO +85°C
TRANSIENT 50 ms
—
—
50
—
—
50
—
—
50
NO LOAD
—
15
20
—
20
35
—
20
35
FULL LOAD
—
—
1370
—
—
1400
—
—
1400
INHIBITED
—
—
15
—
—
22
—
—
22
OUTPUT RIPPLE
INPUT CURRENT
mV
VDC
mA
INPUT RIPPLE
CURRENT
BW ≤ 2 MHz
—
5
15
—
10
25
—
10
25
79
82
—
80
84
—
82
86
—
%
DELAY2
—
15
—
—
30
—
—
40
—
ms
OVERSHOOT
—
500
—
—
1200
—
—
1500
—
mV
EFFICIENCY
START-UP
mA p-p
Notes
1. For HR301-2805, with the remote sense pins connected to the load and no resistance between the output pins and load.
2. A low output impedance power source is required on the input to realize this start-up time. If less than full surge current is available, start-up time
will be longer
CAUTION
Permanent damage to the HR301-2805 will result if pin 6 is shorted to ground. Damage may also result if pin 4 or pin 5 is disconnected from the load
during operation with the remote sense leads connected to the load. If remote sense pins are not connected to the load, the output voltage of the
HR301-2805 will rise to approximately 6.2 VDC measured across pins 4 and 5.
B4-40
HR300 SERIES
30 WATT
DC/DC CONVERTERS
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
TRIPLE OUTPUT MODELS
PARAMETER
HR302-2812
TYP
MAX
MIN
+VOUT
11.88
12.0
12.12
14.85
15.0
15.15
– VOUT
11.88
12.0
12.12
14.85
15.0
15.15
OUTPUT VOLTAGE
OUTPUT CURRENT1
MIN
HR302-2815
TYP
MAX
CONDITION
UNITS
VDC
—
—
2.5
—
—
2.0
A
OUTPUT POWER1
OUTPUT RIPPLE
VOLTAGE
–40°C to +85°C
—
—
30.0
—
—
30.0
W
BW ≤ 2 MHz
—
50
90
—
50
90
mV p-p
LINE REGULATION
VIN = 18 TO 36
—
10
30
—
10
40
mV
LOAD REGULATION
NO LOAD TO FULL
—
20
60
—
20
60
mV
+VOUT
—
2.5
3.5
—
2.2
3.2
– VOUT
—
2.5
3.5
—
2.2
3.2
CROSS REGULATION2
INPUT VOLTAGE
–40°C to +85°C
INPUT CURRENT
%
CONTINUOUS
18
28
36
18
28
36
TRANSIENT 50 ms
—
—
50
—
—
50
NO LOAD
FULL LOAD
INHIBITED
—
—
—
35
—
—
50
1350
24
—
—
—
45
—
—
60
1400
24
mA
mA p-p
VDC
INPUT RIPPLE
CURRENT
BW ≤ 2 MHz
—
15
60
—
15
60
80
84
—
81
85
—
%
DELAY3
—
60
—
—
60
—
ms
OVERSHOOT
—
1500
—
—
1500
—
mV
EFFICIENCY
START-UP
Notes
1. Up to 90% of full power is available from either output providing the total power does not exceed 30 watts.
2. The effect on the output voltage of either output (held at 3 watts) when the other output is varied from 3 to 27 watts.
3. A low output impedance power source is required on the input to realize this start-up time. If less than full surge
current is available, start-up time will be longer
PIN OUT
Pin
1
2
3
4
5
6
7
8
9
10
HR301-2805
Positive Input
Inhibit
Sense Return
Output Common
Positive Output
Positive Sense
Case Ground
No connection
No connection
Input Common
Squared corner and dot on
top of cover indicate pin one.
Single Output
Positive Input
Inhibit
No connection
Output Common
Positive Output
No connection
Case Ground
No connection
No connection
Input Common
Dual Output
Positive Input
No connection
Positive Output
Output Common
Negative Output
No connection
Case Ground
Inhibit
Input Common
Input Common
1
2
3
4
5
BOTTOM VIEW
HR300
See Section B8, case J5, for dimensions.
10
9
8
7
6
FIGURE 1: PIN OUT
MODEL NUMBERING KEY
HR30
2 - 28
12
Base Model
Number of Outputs
(1 = single, 2 = dual)
Input Voltage
Output Voltage
B4-41
DC/DC CONVERTERS
HR300 SERIES
30 WATT
Typical Performance Curves: 25°C Tc
88
88
88
86
86 18 V
86
84
84
76
36 V
28 V
80
78
36 V
76
76
74
72
72
70
70
70
68
68
15
20
25
30
36 V
78
74
10
28 V
80
72
5
18 V
82
74
68
5
10
15
20
25
5
30
10
15
20
25
30
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
HR301-2805 Efficiency
FIGURE 2
HR301-2812 Efficiency
FIGURE 3
HR302-2812 Efficiency
FIGURE 4
88
18
18
18 V
86
84
28 V
Input Voltage (Volts)
Efficiency (%)
Efficiency (%)
80
78
82
82
80
78
76
74
36 V
17
HR301-2812
16
HR301-2815
15
72
Inupt Voltage (Volts)
Efficiency (%)
28 V
82
Efficiency (%)
19 V
84
17
HR302-2815
16
HR302-2812
15
70
68
5
10
15
20
30
14
5
10
15
20
25
30
14
5
10
15
20
25
30
Output Power (Watts)
Output Power (Watts)
HR302-2815 Efficiency
HR301-2812 and HR301-2815
Low Line Dropout
HR302-2812 and HR302-2815
Low Line Dropout
FIGURE 5
B4-42
25
Output Power (Watts)
FIGURE 6
24421-009-DTS Rev A
DQ# 2009
All technical information is believed to be accurate, but no responsibility is assumed
for errors or omissions. Interpoint reserves the right to make changes in products
or specifications without notice. HR300 Series is a trademark of Interpoint.
Copyright © 1991 - 1999 Interpoint. All rights reserved.
FIGURE 7
CASES
CASE J
Dot on top of case indicates pin one
CASE J
BOTTOM VIEW
See Figures 36 - 40
for pin configuration
1.350 max
(34.29)
2.720 max
(69.09)
Flange Thickness:
Cases J1 and J5
Case J2
Cases J3 and J4
0.060 (1.52)
0.073 (1.85) max
0.067 +0.005/-0.007 (1.70 +0.13/-0.8)
Materials
Header Case J1
Cold Rolled Steel/Nickel/Gold
Cases J2 - J5
Cold Rolled Steel/Nickel/Tin
Cover Case J1
Kovar/Nickel
Case J2 - J5
Cold Rolled Steel/Nickel/Tin
Pins
#52 alloy (all cases)
Case J1
MHV Series Triple – compression glass seal
MTR Series Triple – ceramic seal
Cases J2 - J5
compression glass seal
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.2) for two decimal places
unless otherwise specified
CAUTION
Heat from reflow or wave soldering may damage
the device. Solder pins individually with heat
application not exceeding 300°C for 10 seconds
per pin.
FIGURE 35: CASE J MAXIMUM DIMENSIONS
Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer
to the numerical dimensions for accuracy.
B8-22
CASES
CASE J
BOTTOM VIEW CASE J4
Flanged cases: Designator required in Case Option position of model number.
FMD28-461 EMI Filter (down-leaded): Screening – Standard or ES
Squared corner and dot on top
of case indicate pin one.
Solder Seal
1.173
(29.79
1
0.040 dia.
(1.02)
2
0.162 dia
(4.11)
0.673
(17.09)
4
3
1.770
(44.96)
5
0.173
(4.39)
1.370
(34.80)
Solder Tip-off
1.980
(50.29)
0.170
(4.32)
0.000
0.210
(5.33)
0.25 (6.4)
0.000
0.505 max
(12.83)
0.000
FIGURE 39: CASE J4
BOTTOM VIEW CASE J5
Flanged cases: Designator required in Case Option position of model number
for MHL Series and MTO Series only.
MHL Series, MTO Series, MTW Series: Screening – Standard or ES
HR300 Series: no screening options
Squared corner and dot on top
of case indicate pin one.
Solder Seal
1.173
(29.79
1
0.040 dia.
(1.02)
2
3
4
5
0.162 dia
(4.11)
0.673
(17.09)
9
8
7
6
1.770
(44.96)
10
0.173
(4.39)
1.370
(34.80)
Solder Tip-off
1.980
(50.29)
0.970
(24.64)
0.570
(14.48)
0.170
(4.32)
0.000
0.210
(5.33)
0.25 (6.4)
0.000
0.505 max
(12.83)
0.000
FIGURE 40: CASE J5
B8-25
QA SCREENING
HR PRODUCTS
HR PRODUCTS
TEST (HR products)
PRE-CAP INSPECTION
Method 2017
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A
Subgroups 1 and 4: +25°C case
HERMETICITY TESTING
Gross Leak, Dip (1 x 10-3)
FINAL VISUAL INSPECTION
Method 2009
STANDARD
yes
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MILPRF-38534.
Applies to the following products:
HR700 Series
HR300 Series
HR150 Series
HR120 Series
HR40 Series