INTERPOINT MHP27015D/ES

FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
–55° to +100°C operation
160 to 400 VDC input
Fully isolated
Magnetic feedback
Fixed frequency, 600 kHz typical
Topology –
Two Switch, Single Ended Forward
450 V / 50 ms transient protection
Inhibit input side and output side
Sync in and out
Indefinite short circuit protection
Remote sense on single models
Up to 85% efficiency
Parallelable: up to 5 converters
DC/DC CONVERTERS
270 VOLT INPUT
MHP270 SERIES
65 WATT
MODELS
VDC OUTPUT
SINGLE
5
12
15
28
DUAL
±5
±12
±15
Size (max.): 3.005 x 1.505 x 0.400 inches (76.33 x 38.23 x 10.16 mm)
See “Case U Maximum Dimensions” and “Case U.”
Weight:
86 grams maximum
Screening: MHP270 Standard or MHP270 ES.
See “QA Screening: MHP270” for more information
DESCRIPTION
The MHP270 Series™ DC/DC converters provide up to 65 watts of
output power over the full –55°C to 100°C temperature range.
MHP270 models operate from a MIL-STD-704 nominal 270 volt DC
power bus – from 160 to 400 VDC continuous operation with surges
to 450 volts – and provide isolated outputs at 5, 12, 15, and 28 VDC.
Parallel operation for all loading conditions is supported without any
requirement for external components.
MHP converters meet a wide variety of military/aerospace performance and environmental specifications. Their continuous operation
input voltage (160 to 400) meets the normal operating limits of MILSTD-704. The unit shuts down above approximately 425 volts, but
it is rated to withstand a surge of up to 450 volts for 50 msec. The
units are built as fully hermetic thick film hybrids in Interpoint’s MILSTD-1772 certified facilities.
MHP270 DC/DC converters are constant frequency, pulse width
modulated switching power supplies which use a quasi-square
wave, two-switch single-ended forward converter design. Tight load
regulation is achieved through a wide-bandwidth magnetic feedback
circuit.
The MHP270 Series offer a complete list of standard features which
include:
Up to five single output MHP converters may be used in parallel to
power a single load by simply connecting the share pins of all units.
Units in this configuration have a 85% current sharing accuracy over
all loading conditions.
Continuous short circuit protection – current limit set at approximately 125%.
MHP Series of converters feature a flexible synchronization scheme
in which units may be synchronized to an external clock or to one
another by using sync in and sync out pins provided on each unit.
MHP converters have a nominal switching frequency of 600 kHz, but
may be synchronized at any frequency from 525 to 675 kHz.
Undervoltage lock-out – shuts down when the input line voltage falls
below approximately 120 VDC to provide smooth initialization.
Soft-start – controlled start-up at turn-on, release from inhibit, and
recovery from load fault conditions.
Remote sense – to provide automatic compensation for voltage
drops on output lines on single output models.
1
DC/DC CONVERTERS
MHP270 SERIES
65 WATT
ABSOLUTE MAXIMUM RATINGS
Input Voltage
• 160 to 400 VDC
Output Power
• 50 to 65 watts depending on model
Lead Soldering Temperature (10 sec)
• 300°C
Storage Temperature Range (Case)
• –65°C to +150°C
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
• 160 to 400 VDC continuous
• 450 VDC for 50 msec transient
Case Operating Temperature (Tc)
• –55 to +100°C full power
SYNC AND INHIBIT (INH1, INH2)
TYPICAL CHARACTERISTICS
Sync In (525 to 675 kHz)
• Duty cycle 40% min, 60% max
• Logic low 0.8 V max
• Logic high 4.5 V min
• If not used, connect to input common
• Referenced to input common
Sync Out - Referenced to input common
Inhibit (INH1, INH2) TTL Open Collector
• Logic low (output disabled)
INH1 referenced to input common
Logic low 0.8 V max
INH2 referenced to output common
Logic low 0.5 V max
• Logic high (output enabled)
Open collector
Output Voltage Temperature Coefficient
• 100 ppm/°C typical
Isolation
• 100 megohm minimum at 500 V
Conversion Frequency
• Free run mode 600 kHz typical
525 kHz. min., 675 kHz max
• External sync range: 525 to 675 kHz
Inhibit Pin Voltage (unit enabled)
• INH1 =12 V typ., INH2 = 5 V typ
Low Line Drop Out - Vout drops 50 mv
• Input voltage 155 VDC max
Undervoltage Lockout
• Input voltage 110 VDC min
Current Limit
• 125% of full load typical
PINS NOT IN USE
Inhibit (INH1, INH2)
Sync Out
Sync In
Share
Sense Lines
No connection
No connection
Connect to input common
Connect to output common
Must be connected to
appropriate outputs
Electrical Characteristics: 25°C Tc, 270 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODELS
MHP27005S
MIN
4.95
TYP MAX
5.00 5.05
MHP27012S
MHP27015S
MHP27028S
MIN TYP MAX
11.88 12.00 12.12
MIN TYP MAX
14.85 15.00 15.15
MIN TYP MAX
27.22 28.00 28.28
PARAMETER
OUTPUT VOLTAGE
CONDITION
UNITS
VDC
OUTPUT CURRENT
VIN = 160 TO 400 VDC
0
—
10
0
—
5
0
—
4.33
0
—
2.32
A
OUTPUT POWER
VIN = 160 TO 400 VDC
0
—
50
0
—
60
0
—
65
0
—
65
W
VOLTAGE
LINE REGULATION
10 kHz - 2 MHz
VIN = 160 TO 400 VDC
—
—
—
—
50
50
—
—
—
—
50
120
—
—
—
—
75
150
—
—
—
—
280
280
mV p-p
mV
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
CONTINUOUS
TRANSIENT1 50 ms
—
160
—
—
270
—
50
400
450
—
160
—
—
270
—
120
400
450
—
160
—
—
270
—
150
400
450
—
160
—
—
270
—
280
400
450
mV
VDC
V
OUTPUT RIPPLE
INPUT CURRENT
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT2
STEP LOAD RESP.
NO LOAD
—
—
20
—
—
20
—
—
20
—
—
20
mA
INHIBITED - INH1
INHIBITED - INH2
—
—
—
—
8
15
—
—
—
—
10
15
—
—
—
—
7
15
—
—
—
—
10
15
mA
10 kHz - 10 MHz
—
76
—
—
50
—
—
81
—
—
50
—
—
80
—
—
45
—
—
80
—
—
50
—
mA p-p
%
POWER DISSIPATION
SHORT CIRCUIT
—
—
19
—
—
19
—
—
19
—
—
23
W
VOUT
—
—
1.5
—
—
1.5
—
—
1.0
—
—
1.0
VDC
—
—
—
—
300
300
—
—
—
—
700
500
—
—
—
—
700
300
—
—
—
—
1800
1000
mV pk
µs
50% – 100% – 50%
TRANSIENT
RECOVERY3
Notes
1. Unit will shut down above approximately 425V but will be undamaged
and will restart when voltage drops into normal range.
2. Indefinite short circuit protection not guaranteed above 100°C case.
2
3. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
MHP270 SERIES
65 WATT
DC/DC CONVERTERS
Electrical Characteristics: 25°C Tc, 270 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODELS1
PARAMETER
OUTPUT VOLTAGE
MHP27005D
MIN TYP MAX
4.95 5.00 5.05
4.95 5.00 5.05
CONDITIONS
+VOUT
–VOUT
MHP27012D
MIN TYP MAX
11.88 12.00 12.12
11.88 12.00 12.12
MHP27015D
MIN TYP MAX
14.85 15.00 15.15
14.85 15.00 15.15
UNITS
VDC
OUTPUT CURRENT2
VIN = 160 TO 400 VDC
0
±5
8.0
0
±2.5
4.0
0
±2.16
3.46
A
OUTPUT POWER2
VIN = 160 TO 400 VDC
0
—
50
0
—
60
0
—
65
W
—
50
100
—
50
125
—
50
125
mV p-p
—
—
100
—
—
120
—
—
150
mV
mV
OUTPUT RIPPLE
10 kHz - 2 MHz
VOLTAGE
± VOUT
LINE REGULATION
VIN = 160 TO 400 VDC
± VOUT
LOAD REGULATION3
NO LOAD TO FULL
—
—
100
—
—
120
—
—
150
CROSS REGULATION4
EFFECT ON –VOUT
—
—
1000
—
—
800
—
—
750
mV
CONTINUOUS
160
270
400
160
270
400
160
270
400
VDC
TRANSIENT5 50 ms
NO LOAD
INHIBITED - INH1
INHIBITED - INH2
0
—
—
—
—
—
—
—
450
20
10
15
0
—
—
—
—
—
—
—
450
20
10
15
0
—
—
—
—
—
—
—
450
20
8
15
V
mA
10 kHz - 10 MHz
BALANCED LOAD
POWER DISSIPATION
SHORT CIRCUIT
VOUT
—
74
—
—
45
—
—
81
—
—
45
—
—
82
—
—
45
—
mA p-p
%
—
—
—
—
8
±2.0
—
—
—
—
7.5
±1.0
—
—
—
—
19
±1.5
W
V
50 %–100% LOAD7
TRANSIENT
—
—
300
—
—
900
—
—
900
mV pk
RECOVERY8
—
—
500
—
—
500
—
—
500
µs
± VOUT
INPUT VOLTAGE
INPUT CURRENT
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT6
STEP LOAD
RESPONSE ± VOUT
Notes
1. Share operation not characterized for dual outputs.
2. Up to 80% of the total output power (current) is available from either output
providing the opposite output is carrying 20% of the power (current) in use.
3. Assumes balanced loads on the outputs.
4. Effect on the negative output from 50%/50% loads to 70%/30% or 70%/30%
loads.
mA
5. Unit will shut down above approximately 425V but will be undamaged
and will restart when voltage drops into normal range.
6. Indefinite short circuit protection not guaranteed above 125°C case.
7. Second output at 50%
8. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
SINGLE OUTPUT MODELS CONNECTION DIAGRAM - SENSE
270 V
Inhibit
+
–
1
Positive Input
2
Input Common
3
INH2
4
INH1
5
Sync In
6
Sync Out
Sync In
Share 12
N/C 11
Pos. Sense 10
9
Sense Return
Output Common
Positive Output
–
8
7
+
RL
REMOTE SENSE CONNECTION
FIGURE 1: SENSE CONNECTIONS
3
DC/DC CONVERTERS
MHP270 SERIES
65 WATT
SINGLE OUTPUT MODELS CONNECTION DIAGRAM - PARALLEL
+
270V
–
1
Positive Input
2
Input Common
3
INH2
4
INH1
5
Sync Out
6
Share 12
N/C 11
Pos. Sense 10
Sense Return 9
8
Output Common
7
Positive Output
MHP270 #1
Sync In
MODEL NUMBERING KEY
+
RL
–
1
Positive Input
2
Input Common
3
INH2
INH1
5
Sync Out
Output Common
Sync In
Positive Output
1 Positive Input
2 Input Common
MHP
270 05 S / ES
Base Model
Input Voltage
Output Voltage
Pos. Sense 10
Sense Return 9
MHP270 #2
4
6
Share 12
N/C 11
Number of Outputs
(S = single, D = dual)
8
Screening
(Standard screening has no designator
in this position.)
7
Share 12
N/C 11
3 INH2
4
MHP270
INH1
5
Sync Out
6
Sync In
#N
Pos. Sense 10
9
Sense Return
Output Common
Positive Output
8
7
FIGURE 2: PARALLEL CONNECTIONS
PIN OUT
Pin
1
2
3
4
5
6
7
8
9
10
11
12
Single Output
Positive Input
Input Common
Inhibit 2 (INH2)
Inhibit 1 (INH1)
Sync Out
Sync In
Positive Output
Output Common
Sense Return
Positive Sense
No connection
Share
Dual Output
Positive Input
Input Common
Inhibit 2 (INH2)
Inhibit 1 (INH1)
Sync Out
Sync In
Positive Output
Output Common
Negative Output
No connection
No connection
Share
Angled corner indicates pin one.
12
1
11
2
3
4
5
6
TOP VIEW
MHP
(Pin side, marked side)
See “Case U Maximum Dimensions”
and “Case U”
FIGURE 3: PIN OUT
4
MHP270 Rev D This revision supercedes all previous releases.
All technical information is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to make changes in
products or specifications without notice. MHP270 Series is a trademark of
Interpoint. Copyright © 1994 - 2005 Interpoint Corporation. All rights reserved.
10
9
8
7
CASES
CASE U MAXIMUM DIMENSIONS
TOP VIEW (PIN SIDE)
Angled corner indicates pin one
1.505 max (38.23)
See Case U for pin configuration
3.005 (76.33) max.
Note: Pins are shown for Case U1.
Materials
Header Cold Rolled Steel/Nickel/Gold
Cover Kovar/Nickel
Pins
#52 alloy/Gold
compression glass seal
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.2) for two decimal places
unless otherwise specified
CAUTION
Heat from reflow or wave soldering may damage the device.
Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin
Case U maximum dimensions, Rev B, September 27 2005
Please refer to the numerical dimensions for accuracy. All information is believed to be accurate,
but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make
changes in products or specifications without notice.
Copyright © 1999-2005 Interpoint Corp. All rights reserved.
5
CASES
TOP VIEW CASE U
MOR Series, MFL Series, MHP Series, MFLHP Series,
FMTR Series. SMFL Series, SMFLHP Series, SMHP Series,
FME EMI Filter, FMD270 EMI Filter, SFCS EMI Filter,
SFME EMI Filter, HUM70 Module, and LCM Module
Seam Seal
Angled corner
indicates pin one.
0.23 (5.8) Lead Length
0.128 dia
(3.25).
1.505 (38.23) max.
0.040 dia
(1.02)
1.380 (35.05)
1.250 (31.75)
1
12
1.050 (26.67)
2
11
0.850 (21.59)
3
10
0.650 (16.51)
4
9
0.450 (11.43)
5
8
0.250 (6.35)
6
7
Seal hole: 0.100 ±0.002 (2.54 ±0.05)
0.220 (5.59
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.3) for two decimal places
unless otherwise specified
CAUTION
Heat from reflow or wave soldering may damage the device.
Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin
Case U, Rev B, September 27, 2005
Please refer to the numerical dimensions for accuracy. All information is believed to be accurate,
but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make
changes in products or specifications without notice.
Copyright © 1999-2005 Interpoint Corp. All rights reserved.
6
0.050 (1.27)
0.000
0.400 (10.16) max.
2.880 (73.15)
3.005 (76.33) max.
2.750 (69.85)
0.000
0.120 (3.05)
0.250 (6.35)
0.120 (3.05)
0.000
QA SCREENING: MHP270 (STANDARD & ES)
MHP270 SCREENING (STANDARD & ES)
TEST
MHP270
STANDARD
MHP270
/ES
Pre-cap Inspection
Method 2017, 2032
yes
yes
Temperature Cycle (10 times)
Method 1010, Cond. B, -55°C to 125°C, ambient
no
yes
Constant Acceleration
Method 2001, 500 g
no
yes
Burn-In
96 hours at 100°C case, typical
no
yes
Final Electrical Test MIL-PRF-38534, Group A
Subgroups 1 and 4: +25°C case
yes
yes
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10-3)
no
no
yes
yes
yes
no
Final Visual Inspection
Method 2009
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
MHP270 Screening Standard & ES
page 1 of 1
QA Screening MHP270 Standard & ES Rev B September 2005.
This revision supercedes all previous releases. All technical information is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to
make changes in products or specifications without notice.
Copyright © 2005 Interpoint Corporation. All rights reserved.
7