AGILENT DRT1-2321

Digital Radio Transmitter Modules
for 21.2 to 23.6␣ GHz
Technical Data
DRT1-23XX
Features
Description
• Integrated Microwave/
Millimeter-Wave Modules
This digital radio transmitter
module is designed for medium
data rate point to point communication systems operating at
23␣ GHz. This module offers
excellent phase noise performance and can be easily phase
locked to a frequency reference.
The transmitter module provides
+20 dBm of output power, ideal
for use in radios using 2 and 4
level FSK modulation. The module
features an ultra low noise silicon
bipolar VCO operating in the S/C
band. A portion of the oscillator
output is coupled off and is
applied to a frequency divider
network.
• Low Phase Noise
• Silicon Bipolar VCO
• Full Band Tuning
• GaAs MMIC Output Stage
• Sample Output for Phase
Locking
• Excellent Tuning Linearity
• 30 dB Attenuator
• Waveguide/SMA RF Output
• Detected Output
Block Diagrams
Transmitter Module Without Attenuator
Modulation Input
Tuning
Voltage
BPF
LO
Signal
Sample
Output
X4
MMIC
AMP
BPF
X2
MMIC
AMP
RF Out 21.2
to 23.6 GHz
+4
Mute
Detector
Transmitter Module With Attenuator
Modulation Input
Tuning
Voltage
MMIC
BPF
LO
X4
MMIC
AMP
BPF
X2
AMP
Attenuator
RF Out 21.2
to 23.6 GHz
MMIC
Signal
Sample
Output
+4
Mute
5965-5090E
Detector
8-12
Attenuator
Control
AMP
The low frequency output (less
than 1 GHz) from the frequency
divider can be easily used to
phase lock the source. The main
oscillator output is applied to a
frequency multiplier network to
produce the desired output
frequency in the 23 GHz range.
The output of this network is
filtered then amplified by a GaAs
MMIC device to produce the
required output power. A detected
sample of the output signal is
provided to facilitate built in test
of key radio components.
Applications
This digital radio module supplies
the transmitter function in radios
operating in the 21.2 to 23.6␣ GHz
band. The source provides close
to 100 mW output power over the
temperature range of -30°C to
+70°C. Included within the
transmitter module is a muting
function to reduce output power
by 50 dB for “hot standby” applications. An internal voltage
controlled attenuator function is
optional allowing for 30 dB
dynamic range adjustment.
DRT1-23XX Absolute Maximum Ratings (TA = -30 to +70ºC)
Parameters
DC Circuit Power +10
+5.0
-5.0
Power Control
Tuning Voltage
Units
Volts
Volts
Volts
Volts
Volts
Ratings
11
+5.5
-4.5
5
17
Notes:
1. Operation in excess of any one of
these parameters may result in
permanent damage.
2. A thermal interface medium must
be used between the bottom of the
package and its mating surface to
ensure optimum heat transfer.
Electrical Characteristics
Part Number
Parameters
RF Tuning Range
Operating Temperature Range
Storage Temperature Range
RF Power Output
Sample Out Frequency
Sample Out Power
Detected Out
Harmonics and Sub-Harmonics
from 2.65 to 55 GHz from carrier [1]
Spurious Output
from 2.65 - 55 GHz [1]
@ fo ± 1.0 GHz
@ fo ± sample out frequency
Phase Noise @ 100 KHz
Tuning Voltage
Input Capacitance, Nom
Main Tuning Sensitivity
Main Tuning Sensitivity Variation
Modulation Bandwidth
Modulation Sensitivity
Modulation Sensitivity Variation
over any 300 MHz
DC Circuit Power +10 Volts
+5 Volts
-5 Volts
Frequency Pushing on +10V Line
based on ± 0.2V variation
Return Loss @ Full Power Output [2]
Mute Control
Mute Control Range
RF Connector
Attenuator Range
Attenuator Control Voltage
RF Output Dynamic Range
Humidity
Non Condensing
Condensing
Case Size
Units
GHz
°C
°C
dBm
MHz
dBm
V
dBc
dBc
dBc
dBc
dBc
V
pf
MHz/V
MHz
MHz/V
DRT1-2321 or DRT1-2322
Min.
Typ.
Max.
21.2
-30
-45
19
663
-10
0.4
20
738
0
2
-30
-85
1
27
260
1.5:1
20
7
-30
-50
-40
-82
16
21.2
-30
-45
19
663
-10
0.4
mA
mA
mA
MHz/V
dB
dBc
V
40
7
175
975
50
50
5
30 Min.
85
95
3.50 x 1.25 x 0.40
%
%
inches
Tested only to 50 GHz
Module is unconditionally stable with this load VSWR of 2.0:1
8-13
335
2.0:1
25
40
175
600
50
50
10
-50
5
30
0
-30
-50
-40
-82
16
1.15:1
WR 42 or Coax
dB
V
738
0
2
-30
27
260
1.5:1
20
10
-50
0
20
-85
335
2.0:1
25
23.6
70
85
1
1.15:1
Notes:
1.
2.
23.6
70
85
DRT1-2311 or DRT1-2312
Min.
Typ.
Max.
0
5
WR 42 or Coax
NA
NA
NA
85
95
3.50 x 1.25 x 0.40
DRT1-23XX Typical Performance
25
24
300
MODULATION
SENSITIVITY
21
19
Spec Min
T = +25°C
T = –30°C
T = +70°C
17
15
21
22
23
250
23
200
TUNING VOLTAGE
22
150
21
2
24
4
6
8
10
12
14
MAIN TUNING (MHz/V)
FREQUENCY (GHz)
P OUT (dBm)
23
100
16
TUNING VOLTAGE (V)
FREQUENCY (GHz)
Figure 1. Power Out vs. Frequency.
Figure 2. Tuning Voltage vs. Frequency
and Modulation Sensitivity.
0
-40
dBc (Hz)
ATTENUATION (dB)
-60
-10
-20
-30
-80
-100
-120
-40
0
1
2
3
4
5
ATTENUATOR VOLTAGE
Figure 3. Dynamic Range Adjust.
Powering Up Instructions
The -5 volts must be applied to the
receiver module before applying
the +5 volts. Likewise when
shutting down the receiver
module the +5␣ volts must be
removed before the -5 volts is
-140
1
10
100
1000
KHz Offset from Carrier
Figure 4. Phase Noise at 23 GHz vs.
KHz Offset from Carrier.
turned off. The +10␣ volts can be
turned on in any sequence. Failure
to follow this procedure could
cause permanent damage to the
module.
Mounting Instructions
Case must be mounted firmly,
with screws, to an adequate
metallic structure that has sufficient thermal properties to
maintain the module case at a
temperature not to exceed 70°C.
Product Options
Specify part number followed by option. For example:
DR T 1 – 23 X X
Model Number Prefix = Digital Radio
1 = SMA Connector
2 = WR-42 Waveguide Connector
T = Transmitter Module
1 = No Attenuator
2 = Attenuator Option
Internal Use
23 = 21.2 to 23.6 GHz Frequency Band
8-14
Case Dimensions
H
DRTI-23XX
S/N XXXX
+5V PA
–5V
DET
ATTEN
GND
GND
MOD
TUNE
+5V DIV
GND
DIV OUT
+10V
1.25
12x .20
3.50
.40 REF
1.89
.65
10x .100
.40 MAX
12x .22
12x Ø .025
SEE DETAIL A
.125
6x Ø .120 THRU
.670
.170
.250
.420
.500
2.430
.335
.375
.120
2.70
DETAIL A
8-15
.700
.445
.500
.445
.500