KINGBRIGHT WP1060ED

1.8mm SOLID STATE LAMP
WP1060ED
Features
ORANGE
Description
1.8mm DIAMETER SMALL SIZE LED LAMP.
The Orange source color devices are made with
ULTRA BRIGHTNESS IS AVAILABLE.
Gallium Arsenide Phosphide on Gallium Phosphide
RELIABLE AND RUGGED.
Orange Light Emitting Diode.
VERSATILE MOUNTING ON P.C. BOARD OR PANEL.
AVAILABLE IN DIFFUSED LENS.
RoHS COMPLIANT.
Package Dimensions
Notes:
1. All dimensions are in millimeters (inches).
2. Tolerance is ±0.25(0.01") unless otherwise noted.
3. Lead spacing is measured where the leads emerge from the package.
4. Specifications are subject to change without notice.
SPEC NO: DSAF2114
REV NO: V.1
DATE: APR/11/2005
PAGE: 1 OF 3
APPROVED: J. Lu
CHECKED: Allen Liu
DRAWN: W.J.ZHU
ERP:1101009374
Selection Guide
Part No.
Dice
WP1060ED
Iv (mcd)
@ 10mA
Lens Type
ORANGE (GaAsP/GaP)
Viewing
Angle
Min.
Typ.
2θ
θ1/2
8
15
70°
ORANGE DIFFUSED
Note:
1. θ1/2 is the angle from optical centerline where the luminous intensity is 1/2 the optical centerline value.
Electrical / Optical Characteristics at TA=25°C
Symbol
Parameter
Device
λpeak
Peak Wavelength
Orange
λD
Dominant Wavelength
∆λ1/2
Typ.
Max.
Units
Test Conditions
627
nm
IF=20mA
Orange
625
nm
IF=20mA
Spectral Line Half-width
Orange
45
nm
IF=20mA
C
Capacitance
Orange
15
pF
VF=0V;f=1MHz
VF
Forward Voltage
Orange
2.0
2.5
V
IF=20mA
IR
Reverse Current
Orange
10
uA
VR = 5V
Absolute Maximum Ratings at TA=25°C
Parameter
Orange
Units
105
mW
DC Forward Current
30
mA
Peak Forward Current [1]
160
mA
5
V
Power dissipation
Reverse Voltage
Operating/Storage Temperature
-40°C To +85°C
Lead Solder Temperature [2]
260°C For 3 Seconds
Lead Solder Temperature [3]
260°C For 5 Seconds
Notes:
1. 1/10 Duty Cycle, 0.1ms Pulse Width.
2. 2mm below package base.
3. 5mm below package base.
SPEC NO: DSAF2114
REV NO: V.1
DATE: APR/11/2005
PAGE: 2 OF 3
APPROVED: J. Lu
CHECKED: Allen Liu
DRAWN: W.J.ZHU
ERP:1101009374
Orange
WP1060ED
Remarks:
If special sorting is required (e.g. binning based on forward voltage, luminous intensity, or wavelength),
the typical accuracy of the sorting process is as follows:
1. Wavelength: +/-1nm
2. Luminous Intensity: +/-15%
3. Forward Voltage: +/-0.1V
Note: Accuracy may depend on the sorting parameters.
SPEC NO: DSAF2114
REV NO: V.1
DATE: APR/11/2005
PAGE: 3 OF 3
APPROVED: J. Lu
CHECKED: Allen Liu
DRAWN: W.J.ZHU
ERP:1101009374