NTE NTE1527

NTE1527
Integrated Circuit
FM, IF Amp/AFC & Meter Driver
Function:
D FM Section:
IF Amp., Det., Driver for Tuning Meter
D AM Section:
Conv., IF Amp
Features:
FM
D Incorporates a Full−Balance Differential Circuit to Obtain Stable, High Gain in the IF Amplifying
Stage
D Incorporates a Low−Distortion, Quadrature Detection Circuit
(0.3% distortion at 100% modulation).
D The Tuning Meter’s Driver Voltage is Logarithmic to Input
AM
D A High−Gain IF Amplifying Stage, with Input Level Allowable up to 100dBµ.
D The Frequency Converting Stage Consists of a Single Transistor, while the Base, Emitter, and
Collector are Provided with Pins to Ensure Handling Ease.
Absolute Maximum Ratings: (TA = +25°C unless otherwise specified)
Supply Voltage (Note 1), VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8V
Power Dissipation, PT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420mW
Operating Temperature Range, Topr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −20° to +70°C
Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55° to +125°C
Note 1. Standard Operating Voltage = 5.5V
Electrical Characteristics: (TA = +25°C unless otherwise specified)
Parameter
FM Limiting Sensitivity
Recovered AF Voltage
Symbol
Vin(lim)
VO
Total Harmonic Distortion
THD
Signal−to−Noise Ratio
S/N
AM Rejection Ratio
AMR
Test Conditions
Min
Typ
Max
Unit
−3dB point
−
30
−
dBµ
106dBµ,
µ 10.7MHz
Mod. = 400Hz and 100%
−
430
−
mV
−
0.3
−
%
−
76
−
dB
−
55
−
dB
FM = 100%, 400Hz,
FM 106dBµ,
AM = 30%, 1kHz mod.
Electrical Characteristics (Cont’d): (TA = +25°C unless otherwise specified)
Parameter
Signal Meter Output
Detector Output Voltage
Symbol
VM
VO−VR
Test Conditions
Min
Typ
Max
Unit
106dBµ
−
1.6
−
V
106dBµ,
at ±100kHz detuning
−
310
−
mV
−
−90
−
mV
∆(VO−VR) (VO−VR) at 0dBµ
DC Offset
AM IF Sensitivity
SIF
Input Level
at Output = 10mV
(Mod. = 400Hz and 30%)
−
32
−
dBµ
Recovered AF Voltage
VO
Input = 74dBµ
−
120
−
mV
Mod. = 400Hz and 30%
−
0.3
−
%
−
60
−
dB
−
55
−
dB
−
45
−
dB/m
Total Harmonic Distortion
THD
Signal−to−Noise Ratio
S/N
AGC Figure of Merit
AGC
Usually Sensitivity
SIF
Between 100dBµ
and itit’ss −10dB
10dB Input Level at
S/N = 20dB
Note 2. FM Input Level; voltage level when SG output is terminated with SG’s Rg.
Note 3. AM Input Level; voltage level when SG output is open.
Pin Connection Diagram
1.007 (25.5) Max
.964 (24.4)
1st AM IF Input 17
FM IF Input 1
18
16 AM Converter Output
17
Bypass 2
15 AM OSC
8
1
Bypass 3
14 AM Converter Input
9
16
Decoupling 4
GND 5
FM Output 6
Detector 7
Phase Compensation 8
GND 18
13 Bypass
.291 (7.4) Max
.248 (6.3)
12 2nd AM IF Output
.252 (6.4)
.200 (5.08)
11 AGC Bias
10 VCC
9 Signal Meter Output
.188
(4.77)
.020
(.508)
.051 (1.29)
.100
(2.54)
Typ
15°
.009
(0.22)