HAMLIN HE3361A1200

www.hamlin.com
HE3300 S.I.L Relay Features and Benefits
Features
Benefits
Applications
• Miniature single in line package
• Available with 5V, 12V or 24V
coil options as standard
• High voltage and power
switching versions
• Normally open, normally closed,
and change over contact
configurations available
• External magnetic shield option
• Single in line configuration
allows high packing densities,
minimising space and cost
• Lower power coil consumption
than competing
electromechanical devices
• Hermetically sealed switching
contact is immune to the effects
of its environment
• Transfer moulded package gives
maximum component
protection
• Security
• Telecoms
• Instrumentation
• Process Control
• Automatic Test Equipment
DIMENSIONS (in) mm
Figure 1 HE3321A, HE3351A, HE3361A, HE3321B
Figure 3 HE3321E
Figure 2 HE3321C
Figure 4 HE3300 (All)
Table 1
Relay Type
Body Type
HE3300
w
h
Transfer Molded
(.950) 24,13
(.300) 7,62
(.335) 8,51
External Shield
(.980) 24,90
(.320) 8,12
(.345) 8,76
HE3300 PCB LAYOUT
HE3321A
HE3321B
HE3351A
HE3361A
l
(Bottom View)
ORDERING INFORMATION
PART NUMBER HE33XX X
HE3321C
HE3321E
Ø (.032) 0,80 HOLE
XX
XX
Model Number
HE3321 - Standard
HE3351 - High Voltage
HE3361 - Power Switching
General Options
00 - No Options
40 - External Magnetic Shield
Contact Type
A - Form A (SPST-NO)
B - Form B (SPST-NC)
C - Form C (SPDT-CO)
E - Form C (SPDT-CO) alternate foot print
Standard Coil
05 - 5 Volt
12 - 12 Volt
24 - 24 Volt
(.200) 5,08 TYP.
(.400) 10,16
(.200) 5,08 TYP.
(.800) 20,32
(.100) 2,54
EXAMPLE: The HE3321A0540 is a 1 Form relay with a 5 Volt coil and external magnetic shield
See next page for: Electrical and Operating Characteristics Description and Coil Characteristics
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
Tel:
Tel:
Tel:
Tel:
+1 920 648 3000 • Fax: +1 920 648 3001 • Email: [email protected]
+44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: [email protected]
+49 (0) 6181 953660 • Fax: +49 (0) 6181 9536666 • Email: [email protected]
+33 (0) 1 4687 0202 • Fax: +33 (0) 1 4686 6786 • Email: [email protected]
52
ISSUE No: 4 DATE: 1/5/3
Table 2
HE3300 Series
Recognised File #E47258
Electrical and Operating Characteristics
Column Number
@ 25˚C.
1
2
3
4
5
Contact Type
Form A
SPST-NO
Standard
Form A
SPST-NO
High
Voltage
Form A
SPST-NO
Power
Switching
Form C
SPST-CO
Standard
Form B
SPST-NC
Standard
Relay Types
HE3321A
HE3351A
HE3361A
HE3321C, E
HE3321B
CONTACT RATINGS
Contact Hamlin
for specific
load/life details
Power, Switching
Voltage, Switching
Current, Switching
Current, Carry
Watt - max.
Vdc - max.
A - max.
A - max.
10
200
0.5
1.2
10
300
1.0
1.5
50
200
1.5
2.0
5
175
0.25
1.5
10
200
0.5
1.2
VOLTAGE
HOLD-OFF
Across Open Contacts
Contacts to Coil
Vdc - min.
Vac - min.
250
2500
450
2500
300
2500
200
2500
250
2500
RESISTANCE
Contact, Initial
Ω - max.
Insulation:Across Open Contacts
Ω - min.
Between Isolated Terminals Ω - min.
0.150
1010
1010
0.150
1010
1010
0.150
1010
1010
0.200
109
1010
0.150
1010
1010
TIMING
Operate Time
Release Time
ms - max.
ms - max.
1.0
1.0
1.0
1.0
1.0
1.0
3.0
3.0
1.0
1.0
ENVIRONMENTAL
Temperature, Operating
Temperature, Storage
Vibration Resistance
°C
°C
G - max.
10-2000 Hz.
G - max.
11 ms, 1⁄2 sine
-40 to +85
-40 to +105
20
-20 to +85
-40 to +105
20
-40 to +85
-40 to +105
20
-40 to +85
-40 to +105
20
-40 to +85
-40 to+ 105
20
50
50
50
50
50
Shock Resistance
Table 3
Contact Form
& Type
HE3300 Series Relay
Electrical &
Dimensions
Operating
Characteristics
1A
SPST-NO
See Table 2
Column 1
See Figure 1
Coil Characteristics @ 25˚C.
Part
Number
Nominal
Coil Voltage
Vdc
Coil
Resistance
±10% Ohms
Must
Operate
Vdc
Must
Release
Vdc
HE3321A0400
5
500
3.75
0.5
Maximum Top View 2,54 mm, 0.1 in. Grid
Coil Voltage
Dot on Case: Pin 1
Vdc
Numbers not printed on case.
22
HE3321A1200
12
500
9.0
1.0
22
HE3321A2400
24
2000
18.0
2.0
44
See Note 1, 2
1B
HE3321B0400
5
500
3.75
0.5
6.5
HE3321B1200
12
500
9.0
1.0
14.0
HE3321B2400
24
2000
18.0
2.0
28.0
HE3321C0500
5
125
3.75
0.5
11
HE3321C1200
12
500
9.0
1.0
22
HE3321C2400
24
2000
18.0
2.0
44
HE3321E0500
5
125
3.75
0.5
11
HE3321E1200
12
500
9.0
1.0
22
HE3321E2400
24
2000
18.0
2.0
44
HE3351A0500
5
125
3.75
0.5
11
HE3351A1200
12
500
9.0
1.0
22
High Voltage
HE3351A2400
24
2000
18.0
2.0
44
1A
HE3361A0500
5
125
3.75
0.5
11
HE3361A1200
12
500
9.0
1.0
22
HE3361A2400
24
2000
18.0
2.0
44
SPST-NC
See Table 2
Column 5
See Figure 1
1C
SPDT-CO
See Table 2
Column 4
See Figure 2
1C
SPDT-CO
See Table 2
Column 4
See Figure 3
1A
SPST-NO
SPST-NO
Power Switching
See Table 2
Column 2
See Table 2
Column 3
See Figure 1
See Figure 1
Notes: 1) HE3321B - Exceeding recommended voltage may cause
contact reclosure.
2) External magnetic shielding not available on 12 and
24 Volt Form B relays.
INFORMATION PROVIDED ON THIS DATA SHEET IS PROVIDED FOR INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE. Product performance may be affected by the application to which the product
is put. Upon request, HAMLIN will assist purchasers by providing information specific to any particular application. HAMLIN disclaims any and all
liability whatsoever for any purchaser’s reliance upon the information contained on this data sheet without further consultation with authorised
representatives of HAMLIN.
53