204pin DDR3 SDRAM SODIMM DDR3 SDRAM Unbuffered SODIMMs Based on 4Gb M-die HMT425S6MFR6C HMT451S6MFR8C HMT41GS6MFR8C *SK hynix reserves the right to change products or specifications without notice. Rev. 1.0 /Jul. 2012 1 Revision History Revision No. History Draft Date Remark 0.1 Initial Release Mar.2011 Preliminary 0.2 Added IDD Specification Jul.2011 0.3 Added 4GB SoDIMM Sep.2011 0.4 Added 2GB SoDIMM(x16) Sep.2011 0.5 JEDEC Spec, IDD(x16) Update Nov.2011 1.0 JEDEC Spec Updated Jul.2012 Rev. 1.0 /Jul. 2012 2 Description SK hynix Unbuffered Small Outline DDR3 SDRAM DIMMs (Unbuffered Small Outline Double Data Rate Synchronous DRAM Dual In-Line Memory Modules) are low power, high-speed operation memory modules that use DDR3 SDRAM devices. These Unbuffered DDR3 SDRAM SODIMMs are intended for use as main memory when installed in systems such as mobile personal computers. Features • VDD=1.5V +/- 0.075V • VDDQ=1.5V +/- 0.075V • VDDSPD=3.0V to 3.6V • Functionality and operations comply with the DDR3 SDRAM datasheet • 8 internal banks • Data transfer rates: PC3-12800, PC3-10600, PC3-8500 • Bi-directional Differential Data Strobe • 8 bit pre-fetch • Burst Length (BL) switch on-the-fly: BL 8 or BC (Burst Chop) 4 • On Die Termination (ODT) supported • This Product is in compliance withe the RoHS directive. Ordering Information Density Organization Component Composition # of ranks HMT425S6MFR6C-G7/H9/PB 2GB 256Mx64 256Mx16(H5TQ4G63MFR)*4 1 HMT451S6MFR8C-G7/H9/PB 4GB 512Mx64 512Mx8(H5TQ4G83MFR)*8 1 HMT41GS6MFR8C-G7/H9/PB 8GB 1Gx64 512Mx8(H5TQ4G83MFR)*16 2 Part Number Rev. 1.0 /Jul. 2012 3 Key Parameters MT/s Grade tCK (ns) CAS Latency (tCK) tRCD (ns) tRP (ns) tRAS (ns) tRC (ns) CL-tRCD-tRP DDR3-1066 -G7 1.875 7 13.125 13.125 37.5 50.625 7-7-7 DDR3-1333 -H9 1.5 9 13.5 13.5 (13.125)* (13.125)* 36 49.5 (49.125)* 9-9-9 DDR3-1600 -PB 1.25 11 13.75 13.75 (13.125)* (13.125)* 35 48.75 (48.125)* 11-11-11 *SK hynix DRAM devices support optional downbinning to CL11, CL9 and CL7. SPD setting is programmed to match. Speed Grade Frequency [MHz] Grade Remark CL5 CL6 CL7 CL8 CL9 CL10 -G7 667 800 1066 1066 -H9 667 800 1066 1066 1333 1333 -PB 667 800 1066 1066 1333 1333 CL11 CL12 CL13 1600 Address Table 2GB(1Rx16) 4GB(1Rx8) 8GB(2Rx8) Refresh Method 8K/64ms 8K/64ms 8K/64ms Row Address A0-A14 A0-A15 A0-A15 Column Address A0-A9 A0-A9 A0-A9 Bank Address BA0-BA2 BA0-BA2 BA0-BA2 Page Size 2KB 1KB 1KB Rev. 1.0 /Jul. 2012 4 Pin Descriptions Pin Name Description Num ber Pin Name Num ber Description CK[1:0] Clock Input, positive line 2 DQ[63:0] Data Input/Output 64 CK[1:0] Clock Input, negative line 2 DM[7:0] Data Masks 8 CKE[1:0] Clock Enables 2 DQS[7:0] Data strobes 8 RAS Row Address Strobe 1 DQS[7:0] Data strobes, negative line 8 CAS Column Address Strobe 1 EVENT Temperature event pin 1 WE Write Enable 1 TEST S[1:0] Chip Selects 2 RESET Address Inputs 14 A10/AP Address Input/Autoprecharge 1 A12/BC Address Input/Burst chop 1 BA[2:0] SDRAM Bank Addresses 3 VREFDQ ODT[1:0] On Die Termination Inputs 2 VREFCA 1 VTT SPD Data Input/Output 1 VDDSPD SPD Address Inputs 2 NC A[9:0],A11, A[15:13] SCL SDA SA[1:0] Serial Presence Detect (SPD) Clock Input Logic Analyzer specific test pin (No connect on SODIMM) 1 Reset Pin 1 VDD Core and I/O Power 18 VSS Ground 52 Input/Output Reference 1 1 Termination Voltage 2 SPD Power 1 Reserved for future use 2 Total: 204 Rev. 1.0 /Jul. 2012 5 Input/Output Functional Descriptions Symbol Type Polarity Function The system clock inputs. All address and command lines are sampled on the cross point of the rising edge of CK and falling edge of CK. A Delay Locked Loop (DLL) circuit is Cross Point driven from the clock inputs and output timing for read operations is synchronized to the input clock. CK0/CK0 CK1/CK1 IN CKE[1:0] IN Active High S[1:0] IN Active Low ODT[1:0] IN Active High Asserts on-die termination for DQ, DM, DQS, and DQS signals if enabled via the DDR3 SDRAM mode register. RAS, CAS, WE IN Active Low When sampled at the cross point of the rising edge of CK, signals CAS, RAS, and WE define the operation to be executed by the SDRAM. VREFDQ VREFCA Supply BA[2:0] IN Activates the DDR3 SDRAM CK signal when high and deactivates the CK signal when low. By deactivating the clocks, CKE low initiates the Power Down mode or the Self Refresh mode. Enables the associated DDR3 SDRAM command decoder when low and disables the command decoder when high. When the command decoder is disabled, new commands are ignored but previous operations continue. Rank 0 is selected by S0; Rank 1 is selected by S1. Reference voltage for SSTL15 inputs. — Selects which SDRAM internal bank of eight is activated. A[9:0], A10/AP, A11, A12/BC A[15:13] IN — During a Bank Activate command cycle, defines the row address when sampled at the cross point of the rising edge of CK and falling edge of CK. During a Read of Write command cycle, defines the column address when sampled at the cross point of the rising edge of CK and falling edge of CK. In addition to the column address, AP is used to invoke autoprecharge operation at the end of the burst read or write cycle. If AP is high autoprecharge is selected and BA0-BAn defines the bank to be precharged. If AP is low, autoprecharge is disabled. During a Precharge command cycle, AP is used in conjunction with BA0-BAn to control which bank(s) to precharge. If AP is high, all banks will be precharged regardless of the state of BA0-BAn inputs. If AP is low, then BA0-BAn are used to define which bank to precharge. A12(BC) is samples during READ and WRITE commands to determine if burst chop (on-the-fly) will be performed (HIGH, no burst chop: LOW, burst chopped). DQ[63:0] I/O — Data Input/Output pins. DM[7:0] IN Active High VDD, VDDSPD VSS Supply DQS[7:0], DQS[7:0] I/O SA[1:0] IN Rev. 1.0 /Jul. 2012 The data write masks, associated with one data byte. In Write mode, DM operates as a byte mask by allowing input data to be written if it is low but blocks the write operation if it is high. In Read mode, DM lines have no effect. Power supplies for core, I/O, Serial Presence Detect, and ground for the module. The data strobes, associated with one data byte, sourced with data transfers. In Write mode, the data strobe is sourced by the controller and is centered in the data window. Cross Point In Read mode, the data strobe is sourced by the DDR3 SDRAMs and is sent at the leading edge of the data window. DQS signals are complements, and timing is relative to the crosspoint of respective DQS and DQS. — These signals are tied at the system planar to either VSS or VDDSPD to configure the serial SPD EEPROM address range. 6 Symbol Type Polarity Function SDA I/O — This bidirectional pin is used to transfer data into or out of the SPD EEPROM. A resistor must be connected from the SDA bus line to VDDSPD on the system planar to act as a pullup. SCL IN — This signal is used to clock data into and out of the SPD EEPROM. A resistor may be connected from the SCL bus time to VDDSPD on the system planar to act as a pullup. EVENT OUT (open drain) VDDSPD Supply Serial EEPROM positive power supply wired to a separate power pin at the connector which supports from 3.0 Volt to 3.6 Volt (nominal 3.3V) operation. RESET IN The RESET pin is connected to the RESET pin on the register and to the RESET pin on the DRAM. TEST Rev. 1.0 /Jul. 2012 This signal indicates that a thermal event has been detected in the thermal sensing device.The system should guarantee the electrical level requirement is met for the Active Low EVENT pin on TS/SPD part. No pull-up resister is provided on DIMM. Used by memory bus analysis tools (unused (NC) on memory DIMMs) 7 Pin Assignments Pin # Front Side Pin # Back Side Pin # Front Side Pin # Back Side Pin # Front Side Pin # Back Side Pin # Front Side Pin # Back Side 1 VREFDQ 2 VSS 53 DQ19 54 VSS 105 VDD 106 VDD 157 DQ42 158 DQ46 3 VSS 4 DQ4 55 VSS 56 DQ28 107 A10/AP 108 BA1 159 DQ43 160 DQ47 5 DQ0 6 DQ5 57 DQ24 58 DQ29 109 BA0 110 RAS 161 VSS 162 VSS 7 DQ1 8 VSS 59 DQ25 60 VSS 111 VDD 112 VDD 163 DQ48 164 DQ52 9 VSS 10 DQS0 61 VSS 62 DQS3 113 WE 114 S0 165 DQ49 166 DQ53 11 DM0 12 DQS0 63 DM3 64 DQS3 115 CAS 116 ODT0 167 VSS 168 VSS 13 VSS 14 VSS 65 VSS 66 VSS 117 VDD 118 VDD 169 DQS6 170 DM6 15 DQ2 16 DQ6 67 DQ26 68 DQ30 119 A132 120 ODT1 171 DQS6 172 VSS 17 DQ3 18 DQ7 69 DQ27 70 DQ31 121 S1 122 NC 173 VSS 174 DQ54 19 VSS 20 VSS 71 VSS 72 VSS 123 VDD 124 VDD 175 DQ50 176 DQ55 21 DQ8 22 DQ12 73 CKE0 74 CKE1 125 TEST 126 VREFCA 177 DQ51 178 VSS 23 DQ9 24 DQ13 75 VDD 76 VDD 127 VSS 128 VSS 179 VSS 180 DQ60 25 VSS 26 VSS 77 NC 78 A152 129 DQ32 130 DQ36 181 DQ56 182 DQ61 27 DQS1 28 DM1 79 BA2 80 A142 131 DQ33 132 DQ37 183 DQ57 184 VSS 29 DQS1 30 RESET 81 VDD 82 VDD 133 VSS 134 VSS 185 VSS 186 DQS7 31 VSS 32 VSS 83 A12/BC 84 A11 135 DQS4 136 DM4 187 DM7 188 DQS7 33 DQ10 34 DQ14 85 A9 86 A7 137 DQS4 138 VSS 189 VSS 190 VSS 35 DQ11 36 DQ15 87 VDD 88 VDD 139 VSS 140 DQ38 191 DQ58 192 DQ62 37 VSS 38 VSS 89 A8 90 A6 141 DQ34 142 DQ39 193 DQ59 194 DQ63 39 DQ16 40 DQ20 91 A5 92 A4 143 DQ35 144 VSS 195 VSS 196 VSS 41 DQ17 42 DQ21 93 VDD 94 VDD 145 VSS 146 DQ44 197 SA0 198 EVENT 43 VSS 44 VSS 95 A3 96 A2 147 DQ40 148 DQ45 199 VDDSPD 200 SDA 45 DQS2 46 DM2 97 A1 98 A0 149 DQ41 150 VSS 201 SA1 202 SCL 47 DQS2 48 VSS 99 VDD 100 VDD 151 VSS 152 DQS5 203 VTT 204 VTT 49 VSS 50 DQ22 101 CK0 102 CK1 153 DM5 154 DQS5 51 DQ18 52 DQ23 103 CK0 104 CK1 155 VSS 156 VSS NC = No Connect; RFU = Reserved Future Use 1. TEST (pin 125) is reserved for bus analysis probes and is NC on normal memory modules. 2. This address might be connected to NC balls of the DRAMs (depending on density); either way they will be connected to the termination resistor. Rev. 1.0 /Jul. 2012 8 Functional Block Diagram SPD/TS VREFCA VREFDQ D0–D3 VDD D0–D3 D0–D3 VSS D0–D3, SPD, Temp sensor CK0 D0–D3 CK0 D0–D3 Terminated at near card edge ODT1 NC S1 NC EVENT Temp Sensor RESET D0-D3 D0 D1 D2 D3 Vtt A[O:N]/BA[O:N] ODT Vtt VDDSPD CK1 A[O:N]/BA[O:N] ODT SDA WP CK1 240ohm +/-1% ODT CKE Address and Control Lines A[O:N]/BA[O:N] CK CKE (SPD) Vtt 240ohm +/-1% D3 CK A[O:N]/BA[O:N] ODT CK CKE CK CKE CK CK A[O:N]/BA[O:N] ODT0 CK0 CKE0 WE CK0 CK WE CAS CAS WE ZQ SCL A0 A1 A2 SCL SA0 SA1 240ohm +/-1% D2 WE CK CAS ZQ SDA The SPD may be integrated with the Temp Sensor or may be a separate component EVENT D1 WE CAS RAS CS LDQS LDQS LDM DQ [0:7] UDQS UDQS UDM DQ [8:15] CS DQS6 DQS6 DM6 DQ [48:55] DQS7 DQS7 DM7 DQ [56:63] ZQ SCL Sensor A0 Temp (with SPD) A1 A2 EVENT SCL SA0 SA1 240ohm +/-1% D0 LDQS LDQS LDM DQ [0:7] UDQS UDQS UDM DQ [8:15] CS DQS4 DQS4 DM4 DQ [32:39] DQS5 DQS5 DM5 DQ [40:47] ZQ LDQS LDQS LDM DQ [0:7] UDQS UDQS UDM DQ [8:15] RAS DQS2 DQS2 DM2 DQ [16:23] DQS3 DQS3 DM3 DQ [24:31] RAS CS LDQS LDQS LDM DQ [0:7] UDQS UDQS UDM DQ [8:15] RAS DQS0 DQS0 DM0 DQ [0:7] DQS1 DQS1 DM1 DQ [8:15] CAS S0 RAS 2GB, 256Mx64 Module(1Rank of x16) NOTES 1. DQ wiring may differ from that shown however, DQ, DM, DQS, and DQS relationships are maintained as shown Rank 0 Vtt Vtt VDD Rev. 1.0 /Jul. 2012 9 240ohm +/-1% SCL A0 Temp Sensor (with SPD) A1 A2 EVENT SCL SA0 SA1 A[O:N]/BA[O:N] ODT EVENT CK CKE SCL A0 A1 A2 SCL SA0 SA1 The SPD may be integrated with the Temp Sensor or may be a separate component (SPD) SDA WP Vtt LDQS LDQS LDM DQ [0:7] ZQ A[O:N]/BA[O:N] ODT CK CKE CK WE D5 A[O:N]/BA[O:N] ODT CK CKE WE SPD/TS VREFCA VREFDQ D0–D7 VDD D0–D7 VSS D0–D7, SPD, Temp sensor CK0 D0–D7 CK0 D0–D7 CK1 S1 NC ODT1 CKE1 NC EVENT Temp Sensor RESET D0-D7 V1 D4 D0 ZQ A[O:N]/BA[O:N] ODT CK CKE CK NC V2 V2 D5 D1 V3 V3 D6 D2 V4 V4 D7 D3 240ohm +/-1% D7 WE CAS LDQS LDQS LDM DQ [0:7] RAS A[O:N]/BA[O:N] ODT CK CKE CK D3 DQS7 DQS7 DM7 DQ[56:63] CS ZQ WE CAS RAS CS DQS DQS DM DQ [0:7] 240ohm +/-1% Terminated near card edge CK1 V1 DQS3 DQS3 DM3 DQ[48:55] D0–D7 240ohm +/-1% D6 CK CAS RAS 240ohm +/-1% ZQ CAS DQS5 DQS5 DM5 DQ[40:47] A[O:N]/BA[O:N] ODT CK CKE DQS DQS DM DQ [0:7] CS A[O:N]/BA[O:N] ODT CK WE CK CKE 240ohm +/-1% D2 CK CAS ZQ WE CAS D1 DQS3 DQS3 DM3 DQ[24:31] RAS 240ohm +/-1% CS ZQ DQS DQS DM DQ [0:7] CS DQS4 DQS4 DM4 DQ[32:39] RAS CS DQS DQS DM DQ [0:7] RAS DQS2 DQS2 DM2 DQ[16:23] Vtt VDDSPD Vtt WE D4 SDA Vtt ZQ CK A[O:N]/BA[O:N] ODT CK CKE CK WE D0 DQS DQS DM DQ [0:7] CAS DQS1 DQS1 DM1 DQ[8:15] RAS 240ohm +/-1% CS CK0 CKE0 ODT0 WE CK0 CAS ZQ CAS RAS DQS DQS DM DQ [0:7] CS DQS0 DQS0 DM0 DQ[0:7] RAS S0 4GB, 512Mx64 Module(1Rank of x8) Address and Control Lines NOTES 1. DQ wiring may differ from that shown however, DQ, DM, DQS, and DQS relationships are maintained as shown Rank 0 Rev. 1.0 /Jul. 2012 10 SCL A0 A1 A2 V2 D9 (SPD) SDA SDA 8GB, 1Gx64 Module(2RankRankof0 x8) Rev. 1.0 /Jul. 2012 V4 D0 EVENT NOTES 1. DQ wiring may differ from that shown however, DQ, DM, DQS, and DQS relationships are maintained as shown D12 V8 D1 Rank 1 D6 V7 V4 D8 SCL SA0 SA1 V9 V3 WP SCL A0 Temp Sensor (with SPD) A1 A2 EVENT D3 V1 V5 D10 V5 D2 V1 V3 V2 D11 V6 D5 D13 D7 V6 Vtt V1 D15 V7 V9 V8 D4 D14 A[O:N]/BA[O:N] ODT WE CK CAS DQS6 DQS6 DM6 DQ[48:55] A[O:N]/BA[O:N] ODT CK CKE CK WE A[O:N]/BA[O:N] ODT CK CKE CK D7 WE 240ohm +/-1% DQS DQS DM DQ [0:7] ZQ DQS5 DQS5 DM5 DQ[40:47] A[O:N]/BA[O:N] ODT WE D5 CK CKE CAS DQS7 DQS7 DM7 DQ[56:43] ZQ CK RAS CS CK CKE 240ohm +/-1% 240ohm +/-1% DQS DQS DM DQ [0:7] RAS DQS4 DQS4 DM4 DQ[32:39] D6 CAS RAS CS ZQ Vtt The SPD may be integrated with the Temp SCL SA0 Sensor or may be SA1 a separate component 240ohm +/-1% D12 CAS A[O:N]/BA[O:N] ODT CK CKE D13 ZQ DQS DQS DM DQ [0:7] CS A[O:N]/BA[O:N] ODT 240ohm +/-1% ZQ DQS DQS DM DQ [0:7] RAS A[O:N]/BA[O:N] ODT CK CKE CK CKE CK WE CAS D15 Vtt CS A[O:N]/BA[O:N] ODT CK CKE WE CK CK WE CAS 240ohm +/-1% ZQ CAS CS 240ohm +/-1% D14 WE RAS CS CAS ZQ DQS DQS DM DQ [0:7] A[O:N]/BA[O:N] ODT CK CKE RAS CS A[O:N]/BA[O:N] ODT CK CK CKE 240ohm +/-1% 240ohm +/-1% D4 DQS DQS DM DQ [0:7] D10 CK RAS CS A[O:N]/BA[O:N] ODT CK CK CKE 240ohm +/-1% RAS CK0 ODT0 A[O:N]/BA[O:N] ODT CK CKE WE CK CAS CAS WE ZQ ZQ DQS DQS DM DQ [0:7] D8 WE CAS ZQ WE CAS CS A[O:N]/BA[O:N] ODT CK CKE 240ohm +/-1% VDD Vtt DQS DQS DM DQ [0:7] D9 LDQS LDQS LDM DQ [0:7] D2 CK RAS CS 240ohm +/-1% 240ohm +/-1% ZQ Cterm Vtt D3 LDQS LDQS LDM DQ [0:7] A[O:N]/BA[O:N] ODT CK CKE CK WE ZQ RAS CS A[O:N]/BA[O:N] ODT CK WE CK CKE 240ohm +/-1% D0 WE CAS CAS CAS DQS DQS DM DQ [0:7] ZQ ZQ LDQS LDQS LDM DQ [0:7] D1 CK0 CKE0 S0 CS A[O:N]/BA[O:N] ODT 240ohm +/-1% RAS LDQS LDQS LDM DQ [0:7] RAS ZQ VDD Cterm CK A[O:N]/BA[O:N] CK1 CKE1 ODT1 CK CKE CK WE CAS RAS RAS CS RAS DQS DQS DM DQ [0:7] CS DQS0 DQS0 DM0 DQ[0:7] RAS 240ohm +/-1% D11 DQS DQS DM DQ [0:7] CS WE ZQ DQS1 DQS1 DM1 DQ[8:15] DQS2 DQS2 DM2 DQ[6:23] CK1 CAS DQS DQS DM DQ [0:7] CS DQS3 DQS3 DM3 DQ[24:31] RAS S1 8GB, 1Gx64 Module(2Rank of x8) Vtt VDDSPD SPD/TS VREFCA VREFDQ D0–D15 VDD D0–D15 VSS D0–D15, SPD, Temp sensor CK0 D0–D7 CK1 D8–D15 CK0 D0–D7 CK1 D8–D15 D0–D15 CKE0 D0-D7 CKE1 D8-D15 S0 D0–D7 S1 D8–D15 ODT0 D0–D7 ODT1 D8–D15 EVENT Temp Sensor RESET D0-D15 11 Absolute Maximum Ratings Absolute Maximum DC Ratings Absolute Maximum DC Ratings Symbol VDD VDDQ Parameter Rating Units Notes Voltage on VDD pin relative to Vss - 0.4 V ~ 1.8 V V 1, 3 Voltage on VDDQ pin relative to Vss - 0.4 V ~ 1.8V V 1, 3 V 1 VIN, VOUT Voltage on any pin relative to Vss TSTG - 0.4 V ~ 1.8 V o -55 to +100 Storage Temperature C 1, 2 Notes: 1. Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. 2. Storage Temperature is the case surface temperature on the center/top side of the DRAM. For the measurement conditions, please refer to JESD51-2 standard. 3. VDD and VDDQ must be within 300mV of each other at all times; and VREF must not be greater than 0.6XVDDQ,When VDD and VDDQ are less than 500mV; VREF may be equal to or less than 300mV. DRAM Component Operating Temperature Range Temperature Range Symbol TOPER Parameter Normal Operating Temperature Range Extended Temperature Range Rating Units Notes 0 to 85 oC 1,2 85 to 95 oC 1,3 Notes: 1. Operating Temperature TOPER is the case surface temperature on the center / top side of the DRAM. For measurement conditions, please refer to the JEDEC document JESD51-2. 2. The Normal Temperature Range specifies the temperatures where all DRAM specifications will be supported. During operation, the DRAM case temperature must be maintained between 0 - 85oC under all operating conditions. 3. Some applications require operation of the DRAM in the Extended Temperature Range between 85oC and 95oC case temperature. Full specifications are guaranteed in this range, but the following additional conditions apply: a. Refresh commands must be doubled in frequency, therefore reducing the Refresh interval tREFI to 3.9 µs. It is also possible to specify a component with 1X refresh (tREFI to 7.8µs) in the Extended Temperature Range. Please refer to the DIMM SPD for option availability b. If Self-Refresh operation is required in the Extended Temperature Range, then it is mandatory to either use the Manual Self-Refresh mode with Extended Temperature Range capability (MR2 A6 = 0b and MR2 A7 = 1b) or enable the optional Auto Self-Refresh mode (MR2 A6 = 1b and MR2 A7 = 0b). DDR3 SDRAMs support Auto Self-Refresh and Extended Temperature Range and please refer to component datasheet and/or the DIMM SPD for tREFI requirements in the Extended Temperature Range. Rev. 1.0 /Jul. 2012 12 AC & DC Operating Conditions Recommended DC Operating Conditions Recommended DC Operating Conditions Symbol VDD VDDQ Parameter Rating Units Notes 1.575 V 1,2 1.575 V 1,2 Min. Typ. Max. Supply Voltage 1.425 1.5 Supply Voltage for Output 1.425 1.5 Notes: 1. Under all conditions, VDDQ must be less than or equal to VDD. 2. VDDQ tracks with VDD. AC parameters are measured with VDD and VDDQ tied together. Rev. 1.0 /Jul. 2012 13 AC & DC Input Measurement Levels AC and DC Logic Input Levels for Single-Ended Signals AC and DC Input Levels for Single-Ended Command and Address Signals Single Ended AC and DC Input Levels for Command and ADDress Symbol Parameter VIH.CA(DC100) VIL.CA(DC100) VIH.CA(AC175) VIL.CA(AC175) VIH.CA(AC150) VIL.CA(AC150) VIH.CA(AC135) VIL.CA(AC135) VIH.CA(AC125) VIL.CA(AC125) VRefCA(DC) DDR3-800/1066/1333/1600 Unit Notes VDD Vref - 0.100 Note2 Vref - 0.175 Note2 Vref - 0.150 - V V V V V V V V V V 1, 5 1, 6 1, 2, 7 1, 2, 8 1, 2, 7 1, 2, 8 1, 2, 7 1, 2, 8 1, 2, 7 1, 2, 8 0.51 * VDD V 3, 4 Min Max DC input logic high DC input logic low AC input logic high AC input logic low AC Input logic high AC input logic low AC input logic high AC input logic low AC Input logic high AC input logic low Vref + 0.100 VSS Vref + 0.175 Note2 Vref + 0.150 Note2 - Reference Voltage for ADD, CMD inputs 0.49 * VDD Notes: 1. For input only pins except RESET, Vref = VrefCA (DC). 2. Refer to "Overshoot and Undershoot Specifications" on page 27. 3. The ac peak noise on VRef may not allow VRef to deviate from VRefCA(DC) by more than +/-1% VDD (for reference: approx. +/- 15 mV). 4. For reference: approx. VDD/2 +/- 15 mV. 5. VIH(dc) is used as a simplified symbol for VIH.CA(DC100) 6. VIL(dc) is used as a simplified symbol for VIL.CA(DC100) 7. VIH(ac) is used as simplified symbol for VIH.CA(AC175), VIH.CA(AC150), VIH.CA(AC135), and VIH.CA(AC125); VIH.CA(AC175) value is used when Vref + 0.175V is referenced, VIH.CA(AC150) value is used when Vref + 0.150V is referenced, VIH.CA(AC135) value is used when Vref + 0.135V is referenced, and VIH.CA(AC125) value is used when Vref + 0.125V is referenced. 8. VIL(ac) is used as simplified symbol for VIL.CA(AC175), VIL.CA(AC150), VIL.CA(AC135), and VIL.CA(AC125); VIL.CA(AC175) value is used when Vref - 0.175V is referenced, VIL.CA(AC150) value is used when Vref - 0.150V is referenced, VIL.CA(AC135) value is used when Vref - 0.135V is referenced, and VIL.CA(AC125) value is used when Vref - 0.125V is referenced. Rev. 1.0 /Jul. 2012 14 AC and DC Input Levels for Single-Ended Signals DDR3 SDRAM will support two Vih/Vil AC levels for DDR3-800 and DDR3-1066 as specified in the table below. DDR3 SDRAM will also support corresponding tDS values (Table 43 and Table 51 in “ DDR3 Device Operation”) as well as derating tables in Table 46 of “DDR3 Device Operation” depending on Vih/Vil AC levels. Single Ended AC and DC Input Levels for DQ and DM Symbol VIH.DQ(DC100) VIL.DQ(DC100) VIH.DQ(AC175) VIL.DQ(AC175) VIH.DQ(AC150) VIL.DQ(AC150) VIH.CA(AC135) VIL.CA(AC135) VRefDQ(DC) Parameter DDR3-800/1066 DDR3-1333/1600 Min Min Max Max DC input logic high Vref + 0.100 VDD Vref + 0.100 VDD DC input logic low VSS Vref - 0.100 VSS Vref - 0.100 AC input logic high Vref + 0.175 Note2 AC input logic low Note2 Vref - 0.175 AC Input logic high Vref + 0.150 Note2 Vref + 0.150 Note2 AC input logic low Note2 Vref - 0.150 Note2 Vref - 0.150 AC input logic high AC input logic low Reference Voltage for DQ, 0.49 * VDD 0.51 * VDD 0.49 * VDD 0.51 * VDD DM inputs Unit Notes V V V V V V V V 1, 5 1, 6 1, 2, 7 1, 2, 8 1, 2, 7 1, 2, 8 1, 2, 7 1, 2, 8 V 3, 4 Notes: 1. Vref = VrefDQ (DC). 2. Refer to "Overshoot and Undershoot Specifications" on page 27. 3. The ac peak noise on VRef may not allow VRef to deviate from VRefDQ(DC) by more than +/-1% VDD (for reference: approx. +/- 15 mV). 4. For reference: approx. VDD/2 +/- 15 mV. 5. VIH(dc) is used as a simplified symbol for VIH.DQ(DC100) 6. VIL(dc) is used as a simplified symbol for VIL.DQ(DC100) 7. VIH(ac) is used as simplified symbol for VIH.DQ(AC175), VIH.DQ(AC150), and VIH.DQ(AC135); VIH.DQ(AC175) value is used when Vref + 0.175V is referenced, VIH.DQ(AC150) value is used when Vref + 0.150V is referenced, and VIH.DQ(AC135) value is used when Vref + 0.135V is referenced. 8. VIL(ac) is used as simplified symbol for VIL.DQ(AC175), VIL.DQ(AC150), and VIL.DQ(AC135); VIL.DQ(AC175) value is used when Vref - 0.175V is referenced, VIL.DQ(AC150) value is used when Vref 0.150V is referenced, and VIL.DQ(AC135) value is used when Vref - 0.135V is referenced. Rev. 1.0 /Jul. 2012 15 Vref Tolerances The dc-tolerance limits and ac-noise limits for the reference voltages VRefCA and VRefDQ are illustrated in figure below. It shows a valid reference voltage VRef (t) as a function of time. (VRef stands for VRefCA and VRefDQ likewise). VRef (DC) is the linear average of VRef (t) over a very long period of time (e.g. 1 sec). This average has to meet the min/max requirements in the table "Differential Input Slew Rate Definition" on page 22. Furthermore VRef (t) may temporarily deviate from VRef (DC) by no more than +/- 1% VDD. voltage VDD VRef ac-noise VRef(DC) VRef(t) VRef(DC)max VDD/2 VRef(DC)min VSS time Illustration of VRef(DC) tolerance and VRef ac-noise limits The voltage levels for setup and hold time measurements VIH(AC), VIH(DC), VIL(AC), and VIL(DC) are dependent on VRef. “VRef ” shall be understood as VRef(DC), as defined in figure above. This clarifies that dc-variations of VRef affect the absolute voltage a signal has to reach to achieve a valid high or low level and therefore the time to which setup and hold is measured. System timing and voltage budgets need to account for VRef(DC) deviations from the optimum position within the data-eye of the input signals. This also clarifies that the DRAM setup/hold specification and derating values need to include time and voltage associated with VRefac-noise. Timing and voltage effects due to ac-noise on VRef up to the specified limit (+/- 1% of VDD) are included in DRAM timings and their associated deratings. Rev. 1.0 /Jul. 2012 16 AC and DC Logic Input Levels for Differential Signals Differential signal definition tDVAC Differential Input Voltage(i.e.DQS - DQS#, CK - CK#) VIL.DIFF.AC.MIN VIL.DIFF.MIN 0 half cycle VIL.DIFF.MAX VIL.DIFF.AC.MAX tDVAC time Definition of differential ac-swing and “time above ac-level” tDVAC Rev. 1.0 /Jul. 2012 17 Differential swing requirements for clock (CK - CK) and strobe (DQS-DQS) Differential AC and DC Input Levels DDR3-800, 1066, 1333, & 1600 Symbol Parameter VIHdiff VILdiff Differential input high Differential input logic low Differential input high ac Differential input low ac VIHdiff (ac) VILdiff (ac) Min Max + 0.200 Note 3 2 x (VIH (ac) - Vref) Note 3 Note 3 - 0.200 Note 3 2 x (VIL (ac) - Vref) Unit Notes V V V V 1 1 2 2 Notes: 1. Used to define a differential signal slew-rate. 2. For CK - CK use VIH/VIL (ac) of AADD/CMD and VREFCA; for DQS - DQS, DQSL, DQSL, DQSU, DQSU use VIH/VIL (ac) of DQs and VREFDQ; if a reduced ac-high or ac-low levels is used for a signal group, then the reduced level applies also here. 3. These values are not defined; however, the single-ended signals Ck, CK, DQS, DQS, DQSL, DQSL, DQSU, DQSU need to be within the respective limits (VIH (dc) max, VIL (dc) min) for single-ended signals as well as the limitations for overshoot and undershoot. Refer to "Overshoot and Undershoot Specifications" on page 27. Allowed time before ringback (tDVAC) for CK - CK and DQS - DQS DDR3-800/1066/1333/1600 Slew Rate [V/ns] tDVAC [ps] @ VIH/Ldiff (ac) = 350mV min max tDVAC [ps] @ VIH/Ldiff (ac) = 300mV min max tDVAC [ps] @ VIH/Ldiff (ac) = 270mV (DQS-DQS)only (Optional) min max > 4.0 75 - 175 - 214 - 4.0 57 - 170 - 214 - 3.0 50 - 167 - 191 - 2.0 38 - 119 1.8 34 - 102 - 131 - 1.6 29 - 81 - 113 - 1.4 22 - 54 - 88 - 1.2 13 - 19 - 56 - 1.0 0 - note - 11 - < 1.0 0 - note - note - 146 note : Rising input differential signal shall become equal to or greater than VIHdiff(ac) level and Falling input differential signal shall become equal to or less than VIL(ac) level. Rev. 1.0 /Jul. 2012 18 Single-ended requirements for differential signals Each individual component of a differential signal (CK, DQS, DQSL, DQSU, CK, DQS, DQSL, of DQSU) has also to comply with certain requirements for single-ended signals. CK and CK have to approximately reach VSEHmin / VSELmax (approximately equal to the ac-levels (VIH (ac) / VIL (ac)) for ADD/CMD signals) in every half-cycle. DQS, DQSL, DQSU, DQS, DQSL have to reach VSEHmin / VSELmax (approximately the ac-levels (VIH (ac) / VIL (ac)) for DQ signals) in every half-cycle preceding and following a valid transition. Note that the applicable ac-levels for ADD/CMD and DQ’s might be different per speed-bin etc. E.g., if VIH.CA(AC150)/VIL.CA(AC150) is used for ADD/CMD signals, then these ac-levels apply also for the singleended signals CK and CK. VDD or VDDQ VSEHmin VSEH VDD/2 or VDDQ/2 CK or DQS VSELmax VSS or VSSQ VSEL time Single-ended requirements for differential signals. Note that, while ADD/CMD and DQ signal requirements are with respect to Vref, the single-ended components of differential signals have a requirement with respect to VDD / 2; this is nominally the same. the transition of single-ended signals through the ac-levels is used to measure setup time. For single-ended components of differential signals the requirement to reach VSELmax, VSEHmin has no bearing on timing, but adds a restriction on the common mode characteristics of these signals. Rev. 1.0 /Jul. 2012 19 Single-ended levels for CK, DQS, DQSL, DQSU, CK, DQS, DQSL or DQSU Symbol VSEH VSEL DDR3-800, 1066, 1333, & 1600 Parameter Single-ended high level for strobes Single-ended high level for Ck, CK Single-ended low level for strobes Single-ended low level for CK, CK Min Max (VDD / 2) + 0.175 (VDD /2) + 0.175 Note 3 Note 3 Note 3 Note 3 (VDD / 2) - 0.175 (VDD / 2) - 0.175 Unit Notes V V V V 1,2 1,2 1,2 1,2 Notes: 1. For CK, CK use VIH/VIL (ac) of ADD/CMD; for strobes (DQS, DQS, DQSL, DQSL, DQSU, DQSU) use VIH/VIL (ac) of DQs. 2. VIH (ac)/VIL (ac) for DQs is based on VREFDQ; VIH (ac)/VIL (ac) for ADD/CMD is based on VREFCA; if a reduced ac-high or ac-low level is used for a signal group, then the reduced level applies also here. 3. These values are not defined; however, the single-ended signals Ck, CK, DQS, DQS, DQSL, DQSL, DQSU, DQSU need to be within the respective limits (VIH (dc) max, VIL (dc) min) for single-ended signals as well as the limitations for overshoot and undershoot. Refer to "Overshoot and Undershoot Specifications" on page 27. Differential Input Cross Point Voltage To guarantee tight setup and hold times as well as output skew parameters with respect to clock and strobe, each cross point voltage of differential input signals (CK, CK and DQS, DQS) must meet the requirements in the table below. The differential input cross point voltage VIX is measured from the actual cross point of true and complement signals to the midlevel between of VDD and VSS Vix Definition Rev. 1.0 /Jul. 2012 20 Cross point voltage for differential input signals (CK, DQS) Symbol Parameter VIX(CK) VIX(DQS) DDR3-800, 1066, 1333, 1600 Unit Notes Min Max Differential Input Cross Point Voltage relative to VDD/2 for CK, CK -150 -175 150 175 mV mV 2 1 Differential Input Cross Point Voltage relative to VDD/2 for DQS, DQS -150 150 mV 2 Notes: 1. Extended range for VIX is only allowed for clock and if single-ended clock input signals CK and CK are monotonic with a single-ended swing VSEL / VSEH of at least VDD/2 +/-250 mV, and when the differential slew rate of CK - CK is larger than 3 V/ns. Refer to the table "Single-ended levels for CK, DQS, DQSL, DQSU, CK, DQS, DQSL or DQSU" on page 20 for VSEL and VSEH standard values. 2. The relation between Vix Min/Max and VSEL/VSEH should satisfy following. (VDD/2) + Vix (Min) - VSEL ≥ 25mV VSEH - ((VDD/2) + Vix(Max)) ≥ 25mV Slew Rate Definitions for Single-Ended Input Signals See 7.5 “Address / Command Setup, Hold and Derating” in “DDR3 Device Operation” for single-ended slew rate definitions for address and command signals. See 7.6 “Data Setup, Hold and Slew Rate Derating” in “DDR3 Device Operation” for single-ended slew rate definition for data signals. Rev. 1.0 /Jul. 2012 21 Slew Rate Definitions for Differential Input Signals Input slew rate for differential signals (CK, CK and DQS, DQS) are defined and measured as shown in table and figure below. Differential Input Slew Rate Definition Measured Description Differential input slew rate for rising edge (CK-CK and DQS-DQS) Differential input slew rate for falling edge (CK-CK and DQS-DQS) Defined by Min Max VILdiffmax VIHdiffmin [VIHdiffmin-VILdiffmax] / DeltaTRdiff VIHdiffmin VILdiffmax [VIHdiffmin-VILdiffmax] / DeltaTFdiff Notes: Differential Input Voltage (i.e. DQS-DQS; CK-CK) The differential signal (i.e. CK-CK and DQS-DQS) must be linear between these thresholds. Delta TRdiff VIHdiffmin 0 VILdiffmax Delta TFdiff Differential Input Slew Rate Definition for DQS, DQS and CK, CK Rev. 1.0 /Jul. 2012 22 AC & DC Output Measurement Levels Single Ended AC and DC Output Levels Table below shows the output levels used for measurements of single ended signals. Single-ended AC and DC Output Levels Symbol Parameter VOH(DC) DC output high measurement level (for IV curve linearity) VOM(DC) DC output mid measurement level (for IV curve linearity) VOL(DC) DC output low measurement level (for IV curve linearity) VOH(AC) AC output high measurement level (for output SR) VOL(AC) AC output low measurement level (for output SR) DDR3-800, 1066, 1333 and 1600 0.8 x VDDQ Unit Notes V 0.5 x VDDQ 0.2 x VDDQ V VTT + 0.1 x VDDQ VTT - 0.1 x VDDQ V 1 V 1 V Notes: 1. The swing of ±0.1 x VDDQ is based on approximately 50% of the static single ended output high or low swing with a driver impedance of 40 Ω and an effective test load of 25 Ω to VTT = VDDQ / 2. Differential AC and DC Output Levels Table below shows the output levels used for measurements of single ended signals. Differential AC and DC Output Levels DDR3-800, 1066, Symbol Parameter VOHdiff (AC) AC differential output high measurement level (for output SR) 1333 and 1600 + 0.2 x VDDQ VOLdiff (AC) AC differential output low measurement level (for output SR) - 0.2 x VDDQ Unit Notes V 1 V 1 Notes: 1. The swing of ±0.2 x VDDQ is based on approximately 50% of the static differential output high or low swing with a driver impedance of 40 Ω and an effective test load of 25 Ω to VTT = VDDQ/2 at each of the differential outputs. Rev. 1.0 /Jul. 2012 23 Single Ended Output Slew Rate When the Reference load for timing measurements, output slew rate for falling and rising edges is defined and measured between VOL(AC) and VOH(AC) for single ended signals are shown in table and figure below. Single-ended Output slew Rate Definition Measured Description Defined by From To Single-ended output slew rate for rising edge VOL(AC) VOH(AC) [VOH(AC)-VOL(AC)] / DeltaTRse Single-ended output slew rate for falling edge VOH(AC) VOL(AC) [VOH(AC)-VOL(AC)] / DeltaTFse Notes: 1. Output slew rate is verified by design and characterisation, and may not be subject to production test. Single Ended Output Voltage(l.e.DQ) Delta TRse VOH(AC) V∏ VOl(AC) Delta TFse Single Ended Output slew Rate Definition Output Slew Rate (single-ended) DDR3-800 DDR3-1066 DDR3-1333 DDR3-1600 Parameter Symbol Min Max Min Max Min Max Min Max Single-ended Output Slew Rate SRQse 2.5 5 2.5 5 2.5 5 2.5 5 Units V/ns Description: SR; Slew Rate Q: Query Output (like in DQ, which stands for Data-in, Query-Output) se: Single-ended Signals For Ron = RZQ/7 setting Note 1): In two cases, a maximum slew rate of 6V/ns applies for a single DQ signal within a byte lane. Case 1 is a defined for a single DQ signal within a byte lane which is switching into a certain direction (either from high to low or low to high) while all remaining DQ signals in the same byte lane are static (i.e. they stay at either high or low). Case 2 is a defined for a single DQ signal within a byte lane which is switching into a certain direction (either from high to low or low to high) while all remaining DQ signals in the same byte lane switching into the opposite direction (i.e. from low to high of high to low respectively). For the remaining DQ signal switching in to the opposite direction, the regular maximum limite of 5 V/ns applies. Rev. 1.0 /Jul. 2012 24 Differential Output Slew Rate With the reference load for timing measurements, output slew rate for falling and rising edges is defined and measured between VOLdiff (AC) and VOHdiff (AC) for differential signals as shown in table and Figure below. Differential Output Slew Rate Definition Measured Description Defined by From To Differential output slew rate for rising edge VOLdiff (AC) VOHdiff (AC) [VOHdiff (AC)-VOLdiff (AC)] / DeltaTRdiff Differential output slew rate for falling edge VOHdiff (AC) VOLdiff (AC) [VOHdiff (AC)-VOLdiff (AC)] / DeltaTFdiff Notes: 1. Output slew rate is verified by design and characterization, and may not be subject to production test. Differential Output Voltage(i.e. DQS-DQS) Delta TRdiff VOHdiff(AC) O VOLdiff(AC) Delta TFdiff Differential Output slew Rate Definition Differential Output Slew Rate DDR3-800 DDR3-1066 DDR3-1333 DDR3-1600 Parameter Symbol Min Max Min Max Min Max Min Max Differential Output Slew Rate SRQdiff 5 10 5 10 5 10 5 12 Units V/ns Description: SR; Slew Rate Q: Query Output (like in DQ, which stands for Data-in, Query-Output) diff : Differential Signals For Ron = RZQ/7 setting Rev. 1.0 /Jul. 2012 25 Reference Load for AC Timing and Output Slew Rate Figure below represents the effective reference load of 25 ohms used in defining the relevant AC timing parameters of the device as well as output slew rate measurements. It is not intended as a precise representation of any particular system environment or a depiction of the actual load presented by a production tester. System designers should use IBIS or other simulation tools to correlate the timing reference load to a system environment. Manufacturers correlate to their production test conditions, generally one or more coaxial transmission lines terminated at the tester electronics. VDDQ CK, CK DUT DQ DQS DQS 25 Ohm VTT = VDDQ/2 Reference Load for AC Timing and Output Slew Rate Rev. 1.0 /Jul. 2012 26 Overshoot and Undershoot Specifications Address and Control Overshoot and Undershoot Specifications AC Overshoot/Undershoot Specification for Address and Control Pins DDR3- DDR3- DDR3- DDR3- Parameter Units 800 1066 1333 1600 Maximum peak amplitude allowed for overshoot area. (See Figure below) 0.4 0.4 0.4 0.4 V Maximum peak amplitude allowed for undershoot area. (See Figure below) 0.4 0.4 0.4 0.4 V Maximum overshoot area above VDD (See Figure below) 0.67 0.5 0.4 0.33 V-ns Maximum undershoot area below VSS (See Figure below) 0.67 0.5 0.4 0.33 V-ns (A0-A15, BA0-BA3, CS, RAS, CAS, WE, CKE, ODT) See figure below for each parameter definition M axim um Am plitude O vershoot Area V olts (V) VDD V SS U ndershoot Area M axim um A m plitude Tim e (ns) Address and Control Overshoot and Undershoot Definition Rev. 1.0 /Jul. 2012 27 Clock, Data, Strobe and Mask Overshoot and Undershoot Specifications AC Overshoot/Undershoot Specification for Clock, Data, Strobe and Mask DDR3- DDR3- DDR3- DDR3- Parameter Maximum peak amplitude allowed for overshoot area. (See Figure below) Maximum peak amplitude allowed for undershoot area. (See Figure below) Maximum overshoot area above VDD (See Figure below) Maximum undershoot area below VSS (See Figure below) 800 1066 1333 1600 0.4 0.4 0.25 0.25 0.4 0.4 0.19 0.19 0.4 0.4 0.15 0.15 0.4 0.4 0.13 0.13 Units V V V-ns V-ns (CK, CK, DQ, DQS, DQS, DM) See figure below for each parameter definition M axim um Am plitude Overshoot Area Volts (V) VDDQ VSSQ Undershoot Area M axim um Am plitude Tim e (ns) Clock, Data, Strobe and Mask Overshoot and Undershoot Definition Rev. 1.0 /Jul. 2012 28 Refresh parameters by device density Refresh parameters by device density Parameter REF command ACT or REF command time Average periodic refresh interval Rev. 1.0 /Jul. 2012 RTT_Nom Setting 512Mb 1Gb 2Gb 4Gb 8Gb Units tRFC 90 110 160 260 350 ns 7.8 7.8 7.8 7.8 7.8 us 3.9 3.9 3.9 3.9 3.9 us tREFI 0 C TCASE 85 C 85 C TCASE 95 C 29 Standard Speed Bins DDR3 SDRAM Standard Speed Bins include tCK, tRCD, tRP, tRAS and tRC for each corresponding bin. DDR3-800 Speed Bins For specific Notes See "Speed Bin Table Notes" on page 34. Speed Bin DDR3-800E CL - nRCD - nRP 6-6-6 Unit Notes Parameter Symbol min max Internal read command to first data tAA 15 20 ns ACT to internal read or write delay time tRCD 15 — ns PRE command period tRP 15 — ns ACT to ACT or REF command period tRC 52.5 — ns ACT to PRE command period tRAS 37.5 9 * tREFI ns CWL = 5 tCK(AVG) 3.0 3.3 ns 1, 2, 3, 4, 10 CWL = 5 tCK(AVG) 2.5 3.3 ns 1, 2, 3 Supported CL Settings 5, 6 nCK 10 Supported CWL Settings 5 nCK CL = 5 CL = 6 Rev. 1.0 /Jul. 2012 30 DDR3-1066 Speed Bins For specific Notes See "Speed Bin Table Notes" on page 34. Speed Bin DDR3-1066F CL - nRCD - nRP Parameter Symbol Unit 7-7-7 min max Note Internal read command to first data tAA 13.125 20 ns ACT to internal read or write delay time tRCD 13.125 — ns PRE command period tRP 13.125 — ns ACT to ACT or REF command period tRC 50.625 — ns ACT to PRE command period tRAS 37.5 9 * tREFI ns CWL = 5 tCK(AVG) 3.0 3.3 ns 1, 2, 3, 4, 6, 10 CWL = 6 tCK(AVG) ns 4 CWL = 5 tCK(AVG) ns 1, 2, 3, 6 CWL = 6 tCK(AVG) Reserved ns 1, 2, 3, 4 CWL = 5 tCK(AVG) Reserved ns 4 CWL = 6 tCK(AVG) ns 1, 2, 3, 4 CWL = 5 tCK(AVG) ns 4 CWL = 6 tCK(AVG) ns 1, 2, 3 5, 6, 7, 8 nCK 10 5, 6 nCK CL = 5 CL = 6 CL = 7 CL = 8 Supported CL Settings Supported CWL Settings Rev. 1.0 /Jul. 2012 Reserved 2.5 3.3 1.875 < 2.5 Reserved 1.875 < 2.5 31 DDR3-1333 Speed Bins For specific Notes See "Speed Bin Table Notes" on page 34. Speed Bin DDR3-1333H CL - nRCD - nRP Parameter Symbol Unit 9-9-9 min max Note Internal read command to first data tAA 13.5 (13.125)5,9 20 ns ACT to internal read or write delay time tRCD 13.5 (13.125)5,9 — ns PRE command period tRP 13.5 (13.125)5,9 — ns ACT to ACT or REF command period tRC 49.5 (49.125)5,9 — ns ACT to PRE command period tRAS 36 9 * tREFI ns CWL = 5 tCK(AVG) 3.0 3.3 ns 1, 2, 3, 4, 7, 10 CWL = 6, 7 tCK(AVG) ns 4 CWL = 5 tCK(AVG) ns 1, 2, 3, 7 CWL = 6 tCK(AVG) Reserved ns 1, 2, 3, 4, 7 CWL = 7 tCK(AVG) Reserved ns 4 CWL = 5 tCK(AVG) Reserved ns 4 CWL = 6 tCK(AVG) ns 1, 2, 3, 4, 7 CWL = 7 tCK(AVG) Reserved ns 1, 2, 3, 4 CWL = 5 tCK(AVG) Reserved ns 4 CWL = 6 tCK(AVG) ns 1, 2, 3, 7 CWL = 7 tCK(AVG) Reserved ns 1, 2, 3, 4 CWL = 5, 6 tCK(AVG) Reserved ns 4 CWL = 7 tCK(AVG) ns 1, 2, 3, 4 CWL = 5, 6 tCK(AVG) ns 4 CWL = 7 tCK(AVG) (Optional) ns ns 1, 2, 3 5 Supported CL Settings 6, (7), 8, 9, (10) nCK Supported CWL Settings 5, 6, 7 nCK CL = 5 CL = 6 CL = 7 CL = 8 CL = 9 CL = 10 Rev. 1.0 /Jul. 2012 Reserved 2.5 3.3 1.875 < 2.5 (Optional)5,9 1.875 < 2.5 1.5 <1.875 Reserved 1.5 <1.875 32 DDR3-1600 Speed Bins For specific Notes See "Speed Bin Table Notes" on page 34. Speed Bin DDR3-1600K CL - nRCD - nRP Parameter Symbol Unit 11-11-11 min max Internal read command to first data tAA 13.75 (13.125)5,9 20 ns ACT to internal read or write delay time tRCD 13.75 (13.125)5,9 — ns PRE command period tRP 13.75 (13.125)5,9 — ns ACT to ACT or REF command period tRC 48.75 (48.125)5,9 — ns ACT to PRE command period tRAS 35 9 * tREFI ns CWL = 5 tCK(AVG) 3.0 3.3 ns CWL = 6, 7 tCK(AVG) tCK(AVG) tCK(AVG) tCK(AVG) tCK(AVG) CL = 5 CWL = 5 CL = 6 CWL = 6 CWL = 7 CWL = 5 CL = 7 CWL = 6 tCK(AVG) CWL = 7 tCK(AVG) tCK(AVG) tCK(AVG) tCK(AVG) tCK(AVG) tCK(AVG) tCK(AVG) CWL = 8 CWL = 5 CL = 8 CWL = 6 CWL = 7 CWL = 8 CWL = 5, 6 CL = 9 CWL = 7 tCK(AVG) tCK(AVG) CWL = 5, 6 tCK(AVG) tCK(AVG) CL = 10 CWL = 7 tCK(AVG) CWL = 8 CWL = 5, 6,7 tCK(AVG) CL = 11 tCK(AVG) CWL = 8 ns 1, 2, 3, 4, 8, 10 4 ns 1, 2, 3, 8 Reserved ns 1, 2, 3, 4, 8 Reserved ns 4 ns 4 ns 1, 2, 3, 4, 8 ns 1, 2, 3, 4, 8 ns 4 ns 4 Reserved 2.5 3.3 Reserved 1.875 < 2.5 (Optional)5,9 Reserved Reserved Reserved 1.875 < 2.5 Reserved Reserved Reserved 1.5 <1.875 (Optional)5,9 Reserved CWL = 8 Reserved 1.5 <1.875 Reserved Reserved 1.25 <1.5 Supported CL Settings 5, 6, (7), 8, (9), 10, 11 Supported CWL Settings 5, 6, 7, 8 Rev. 1.0 /Jul. 2012 Note ns 1, 2, 3, 8 ns 1, 2, 3, 4, 8 ns 1, 2, 3, 4 ns 4 ns 1, 2, 3, 4, 8 ns 1, 2, 3, 4 ns 4 ns 1, 2, 3, 8 ns 1, 2, 3, 4 ns 4 ns 1, 2, 3 nCK nCK 33 Speed Bin Table Notes Absolute Specification (TOPER; VDDQ = VDD = 1.5V +/- 0.075 V); 1. The CL setting and CWL setting result in tCK(AVG).MIN and tCK(AVG).MAX requirements. When making a selection of tCK(AVG), both need to be fulfilled: Requirements from CL setting as well as requirements from CWL setting. 2. tCK(AVG).MIN limits: Since CAS Latency is not purely analog - data and strobe output are synchronized by the DLL - all possible intermediate frequencies may not be guaranteed. An application should use the next smaller JEDEC standard tCK(AVG) value (3.0, 2.5, 1.875, 1.5, or 1.25 ns) when calculating CL [nCK] = tAA [ns] / tCK(AVG) [ns], rounding up to the next ‘Supported CL’, where tCK(AVG) = 3.0 ns should only be used for CL = 5 calculation. 3. tCK(AVG).MAX limits: Calculate tCK(AVG) = tAA.MAX / CL SELECTED and round the resulting tCK(AVG) down to the next valid speed bin (i.e. 3.3ns or 2.5ns or 1.875 ns or 1.25 ns). This result is tCK(AVG).MAX corresponding to CL SELECTED. 4. ‘Reserved’ settings are not allowed. User must program a different value. 5. ‘Optional’ settings allow certain devices in the industry to support this setting, however, it is not a mandatory feature. Refer to DIMM data sheet and/or the DIMM SPD information if and how this setting is supported. 6. Any DDR3-1066 speed bin also supports functional operation at lower frequencies as shown in the table which are not subject to Production Tests but verified by Design/Characterization. 7. Any DDR3-1333 speed bin also supports functional operation at lower frequencies as shown in the table which are not subject to Production Tests but verified by Design/Characterization. 8. Any DDR3-1600 speed bin also supports functional operation at lower frequencies as shown in the table which are not subject to Production Tests but verified by Design/Characterization. 9. DDR3 SDRAM devices supporting optional down binning to CL=7 and CL=9, and tAA/tRCD/tRP must be 13.125 ns or lower. SPD settings must be programmed to match. For example, DDR3-1333H devices supporting down binning to DDR3-1066F should program 13.125 ns in SPD bytes for tAAmin (Byte 16), tRCDmin (Byte 18), and tRPmin (Byte 20). DDR3-1600K devices supporting down binning to DDR3-1333H or DDR3-1600F should program 13.125 ns in SPD bytes for tAAmin (Byte 16), tRCDmin (Byte 18), and tRPmin (Byte 20). Once tRP (Byte 20) is programmed to 13.125ns, tRCmin (Byte 21,23) also should be programmed accordingly. For example, 49.125ns (tRASmin + tRPmin = 36 ns + 13.125 ns) for DDR3-1333H and 48.125ns (tRASmin + tRPmin = 35 ns + 13.125 ns) for DDR3-1600K. 10. For CL5 support, refer to DIMM SPD information. DRAM is required to support CL5. CL5 is not mandatory in SPD coding. 11. DDR3 SDRAM devices supporting optional down binning to CL=11, CL=9 and CL=7, tAA/tRCD/tRPmin must be 13.125ns. SPD setting must be programed to match. For example, DDR3-1866M devices supporting down binning to DDR3-1600K or DDR3-1333H or 1066F should program 13.125ns in SPD bytes for tAAmin(byte16), tRCDmin(byte18) and tRPmin(byte20). Once tRP (byte20) is programmed to 13.125ns, tRCmin(byte 21,23) also should be programmed accordingly. For example, 47.125ns(tRASmin + tRPmin = 34ns + 13.125ns) Rev. 1.0 /Jul. 2012 34 Environmental Parameters Symbol Parameter Rating TOPR Operating temperature 0 to 65 HOPR Operating humidity (relative) 10 to 90 TSTG Storage temperature HSTG Storage humidity (without condensation) PBAR Barometric Pressure (operating & storage) Units o Notes C 1, 3 % 1 o C 1 5 to 95 % 1 105 to 69 K Pascal 1, 2 -50 to +100 Note: 1. Stress greater than those listed may cause permanent damage to the device. This is a stress rating only, and device functional operation at or above the conditions indicated is not implied. Expousure to absolute maximum rating conditions for extended periods may affect reliablility. 2. Up to 9850 ft. 3. The designer must meet the case temperature specifications for individual module components. Rev. 1.0 /Jul. 2012 35 IDD and IDDQ Specification Parameters and Test Conditions IDD and IDDQ Measurement Conditions In this chapter, IDD and IDDQ measurement conditions such as test load and patterns are defined. Figure 1. shows the setup and test load for IDD and IDDQ measurements. • IDD currents (such as IDD0, IDD1, IDD2N, IDD2NT, IDD2P0, IDD2P1, IDD2Q, IDD3N, IDD3P, IDD4R, IDD4W, IDD5B, IDD6, IDD6ET and IDD7) are measured as time-averaged currents with all VDD balls of the DDR3 SDRAM under test tied together. Any IDDQ current is not included in IDD currents. • IDDQ currents (such as IDDQ2NT and IDDQ4R) are measured as time-averaged currents with all VDDQ balls of the DDR3 SDRAM under test tied together. Any IDD current is not included in IDDQ currents. Attention: IDDQ values cannot be directly used to calculate IO power of the DDR3 SDRAM. They can be used to support correlation of simulated IO power to actual IO power as outlined in Figure 2. In DRAM module application, IDDQ cannot be measured separately since VDD and VDDQ are using one merged-power layer in Module PCB. For IDD and IDDQ measurements, the following definitions apply: • ”0” and “LOW” is defined as VIN <= VILAC(max). • ”1” and “HIGH” is defined as VIN >= VIHAC(max). • “MID_LEVEL” is defined as inputs are VREF = VDD/2. • Timing used for IDD and IDDQ Measurement-Loop Patterns are provided in Table 1. • Basic IDD and IDDQ Measurement Conditions are described in Table 2. • Detailed IDD and IDDQ Measurement-Loop Patterns are described in Table 3 through Table 10. • IDD Measurements are done after properly initializing the DDR3 SDRAM. This includes but is not limited to setting RON = RZQ/7 (34 Ohm in MR1); Qoff = 0B (Output Buffer enabled in MR1); RTT_Nom = RZQ/6 (40 Ohm in MR1); RTT_Wr = RZQ/2 (120 Ohm in MR2); TDQS Feature disabled in MR1 • Attention: The IDD and IDDQ Measurement-Loop Patterns need to be executed at least one time before actual IDD or IDDQ measurement is started. • Define D = {CS, RAS, CAS, WE}:= {HIGH, LOW, LOW, LOW} Define D = {CS, RAS, CAS, WE}:= {HIGH, HIGH, HIGH, HIGH} Rev. 1.0 /Jul. 2012 36 IDDQ (optional) IDD VDD VDDQ RESET CK/CK DDR3 SDRAM CKE CS RAS, CAS, WE DQS, DQS DQ, DM, TDQS, TDQS A, BA ODT ZQ VSS RTT = 25 Ohm VDDQ/2 VSSQ Figure 1 - Measurement Setup and Test Load for IDD and IDDQ (optional) Measurements [Note: DIMM level Output test load condition may be different from above Application specific memory channel environment IDDQ Test Load Channel IO Power Simulation IDDQ Simulation IDDQ Simulation Correction Channel IO Power Number Figure 2 - Correlation from simulated Channel IO Power to actual Channel IO Power supported by IDDQ Measurement Rev. 1.0 /Jul. 2012 37 Table 1 -Timings used for IDD and IDDQ Measurement-Loop Patterns Symbol tCK DDR3-1066 DDR3-1333 DDR3-1600 7-7-7 9-9-9 11-11-11 1.875 1.5 1.25 ns Unit CL 7 9 11 nCK nRCD 7 9 11 nCK nRC 27 33 39 nCK nRAS 20 24 28 nCK nRP 7 9 11 nCK 1KB page size 20 20 24 nCK 2KB page size 27 30 32 nCK 1KB page size 4 4 5 nCK nFAW nRRD 2KB page size nRFC -512Mb 6 5 6 nCK 48 60 72 nCK nRFC-1 Gb 59 74 88 nCK nRFC- 2 Gb 86 107 128 nCK nRFC- 4 Gb 139 174 208 nCK nRFC- 8 Gb 187 234 280 nCK Table 2 -Basic IDD and IDDQ Measurement Conditions Symbol Description Operating One Bank Active-Precharge Current CKE: High; External clock: On; tCK, nRC, nRAS, CL: see Table 1; BL: 8a); AL: 0; CS: High between ACT and IDD0 PRE; Command, Address, Bank Address Inputs: partially toggling according to Table 3; Data IO: MID-LEVEL; DM: stable at 0; Bank Activity: Cycling with one bank active at a time: 0,0,1,1,2,2,... (see Table 3); Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0; Pattern Details: see Table 3. Operating One Bank Active-Precharge Current CKE: High; External clock: On; tCK, nRC, nRAS, nRCD, CL: see Table 1; BL: 8a); AL: 0; CS: High between ACT, IDD1 RD and PRE; Command, Address; Bank Address Inputs, Data IO: partially toggling according to Table 4; DM: stable at 0; Bank Activity: Cycling with on bank active at a time: 0,0,1,1,2,2,... (see Table 4); Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0; Pattern Details: see Table 4. Rev. 1.0 /Jul. 2012 38 Symbol Description Precharge Standby Current CKE: High; External clock: On; tCK, CL: see Table 1; BL: 8a); AL: 0; CS: stable at 1; Command, Address, Bank IDD2N Address Inputs: partially toggling according to Table 5; Data IO: MID_LEVEL; DM: stable at 0; Bank Activity: all banks closed; Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0; Pattern Details: see Table 5. Precharge Standby ODT Current CKE: High; External clock: On; tCK, CL: see Table 1; BL: 8a); AL: 0; CS: stable at 1; Command, Address, Bank IDD2NT Address Inputs: partially toggling according to Table 6; Data IO: MID_LEVEL; DM: stable at 0; Bank Activity: all banks closed; Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: toggling according to Table 6; Pattern Details: see Table 6. Precharge Power-Down Current Slow Exit IDD2P0 CKE: Low; External clock: On; tCK, CL: see Table 1; BL: 8a); AL: 0; CS: stable at 1; Command, Address, Bank Address Inputs: stable at 0; Data IO: MID_LEVEL; DM: stable at 0; Bank Activity: all banks closed; Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0; Precharge Power Down Mode: Slow Exitc) Precharge Power-Down Current Fast Exit IDD2P1 CKE: Low; External clock: On; tCK, CL: see Table 1; BL: 8a); AL: 0; CS: stable at 1; Command, Address, Bank Address Inputs: stable at 0; Data IO: MID_LEVEL; DM: stable at 0; Bank Activity: all banks closed; Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0; Precharge Power Down Mode: Fast Exitc) Precharge Quiet Standby Current IDD2Q CKE: High; External clock: On; tCK, CL: see Table 1; BL: 8a); AL: 0; CS: stable at 1; Command, Address, Bank Address Inputs: stable at 0; Data IO: MID_LEVEL; DM: stable at 0; Bank Activity: all banks closed; Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0 Active Standby Current CKE: High; External clock: On; tCK, CL: see Table 1; BL: 8a); AL: 0; CS: stable at 1; Command, Address, Bank IDD3N Address Inputs: partially toggling according to Table 5; Data IO: MID_LEVEL; DM: stable at 0; Bank Activity: all banks open; Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0; Pattern Details: see Table 5. Active Power-Down Current IDD3P CKE: Low; External clock: On; tCK, CL: see Table 1; BL: 8a); AL: 0; CS: stable at 1; Command, Address, Bank Address Inputs: stable at 0; Data IO: MID_LEVEL; DM: stable at 0; Bank Activity: all banks open; Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0 Rev. 1.0 /Jul. 2012 39 Symbol Description Operating Burst Read Current CKE: High; External clock: On; tCK, CL: see Table 1; BL: 8a); AL: 0; CS: High between RD; Command, Address, IDD4R Bank Address Inputs: partially toggling according to Table 7; Data IO: seamless read data burst with different data between one burst and the next one according to Table 7; DM: stable at 0; Bank Activity: all banks open, RD commands cycling through banks: 0,0,1,1,2,2,...(see Table 7); Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0; Pattern Details: see Table 7. Operating Burst Write Current CKE: High; External clock: On; tCK, CL: see Table 1; BL: 8a); AL: 0; CS: High between WR; Command, Address, IDD4W Bank Address Inputs: partially toggling according to Table 8; Data IO: seamless read data burst with different data between one burst and the next one according to Table 8; DM: stable at 0; Bank Activity: all banks open, WR commands cycling through banks: 0,0,1,1,2,2,...(see Table 8); Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at HIGH; Pattern Details: see Table 8. Burst Refresh Current CKE: High; External clock: On; tCK, CL, nRFC: see Table 1; BL: 8a); AL: 0; CS: High between REF; Command, IDD5B Address, Bank Address Inputs: partially toggling according to Table 9; Data IO: MID_LEVEL; DM: stable at 0; Bank Activity: REF command every nREF (see Table 9); Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0; Pattern Details: see Table 9. Self-Refresh Current: Normal Temperature Range TCASE: 0 - 85 oC; Auto Self-Refresh (ASR): Disabledd);Self-Refresh Temperature Range (SRT): Normale); CKE: IDD6 Low; External clock: Off; CK and CK: LOW; CL: see Table 1; BL: 8a); AL: 0; CS, Command, Address, Bank Address Inputs, Data IO: MID_LEVEL; DM: stable at 0; Bank Activity: Self-Refresh operation; Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: MID_LEVEL Self-Refresh Current: Extended Temperature Range TCASE: 0 - 95 oC; Auto Self-Refresh (ASR): Disabledd);Self-Refresh Temperature Range (SRT): Extendede); IDD6ET CKE: Low; External clock: Off; CK and CK: LOW; CL: see Table 1; BL: 8a); AL: 0; CS, Command, Address, Bank Address Inputs, Data IO: MID_LEVEL; DM: stable at 0; Bank Activity: Extended Temperature Self-Refresh operation; Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: MID_LEVEL Rev. 1.0 /Jul. 2012 40 Symbol Description Operating Bank Interleave Read Current CKE: High; External clock: On; tCK, nRC, nRAS, nRCD, NRRD, nFAW, CL: see Table 1; BL: 8a,f); AL: CL-1; CS: High between ACT and RDA; Command, Address, Bank Address Inputs: partially toggling according to Table IDD7 10; Data IO: read data burst with different data between one burst and the next one according to Table 10; DM: stable at 0; Bank Activity: two times interleaved cycling through banks (0, 1,...7) with different addressing, wee Table 10; Output Buffer and RTT: Enabled in Mode Registersb); ODT Signal: stable at 0; Pattern Details: see Table 10. a) Burst Length: BL8 fixed by MRS: set MR0 A[1,0]=00B b) Output Buffer Enable: set MR1 A[12] = 0B; set MR1 A[5,1] = 01B; RTT_Nom enable: set MR1 A[9,6,2] = 011B; RTT_Wr enable: set MR2 A[10,9] = 10B c) Precharge Power Down Mode: set MR0 A12=0B for Slow Exit or MR0 A12 = 1B for Fast Exit d) Auto Self-Refresh (ASR): set MR2 A6 = 0B to disable or 1B to enable feature e) Self-Refresh Temperature Range (SRT): set MR2 A7 = 0B for normal or 1B for extended temperature range f) Read Burst Type: Nibble Sequential, set MR0 A[3] = 0B Rev. 1.0 /Jul. 2012 41 Command CS RAS CAS WE ODT BA[2:0] A[15:11] A[10] A[9:7] A[6:3] A[2:0] 0 ACT 0 0 1 1 0 0 00 0 0 0 0 - 1,2 D, D 1 0 0 0 0 0 00 0 0 0 0 - D, D 1 1 1 1 0 0 00 0 0 0 0 - 0 0 0 - 0 F 0 - Cycle Number Datab) Sub-Loop CKE CK, CK Table 3 - IDD0 Measurement-Loop Patterna) 0 3,4 ... nRAS ... Static High toggling 1*nRC+0 repeat pattern 1...4 until nRAS - 1, truncate if necessary PRE 0 0 1 0 0 0 00 0 repeat pattern 1...4 until nRC - 1, truncate if necessary ACT 0 0 1 1 0 0 00 0 1*nRC+1, 2 D, D 1 0 0 0 0 0 00 0 0 F 0 - 1*nRC+3, 4 D, D 1 1 1 1 0 0 00 0 0 F 0 - 0 - ... 1*nRC+nRAS repeat pattern 1...4 until 1*nRC + nRAS - 1, truncate if necessary PRE 0 0 1 0 0 0 00 0 0 ... repeat pattern 1...4 until 2*nRC - 1, truncate if necessary 1 2*nRC repeat Sub-Loop 0, use BA[2:0] = 1 instead 2 4*nRC repeat Sub-Loop 0, use BA[2:0] = 2 instead 3 6*nRC repeat Sub-Loop 0, use BA[2:0] = 3 instead 4 8*nRC repeat Sub-Loop 0, use BA[2:0] = 4 instead 5 10*nRC repeat Sub-Loop 0, use BA[2:0] = 5 instead 6 12*nRC repeat Sub-Loop 0, use BA[2:0] = 6 instead 7 14*nRC repeat Sub-Loop 0, use BA[2:0] = 7 instead F a) DM must be driven LOW all the time. DQS, DQS are MID-LEVEL. b) DQ signals are MID-LEVEL. Rev. 1.0 /Jul. 2012 42 Command CS RAS CAS WE ODT BA[2:0] A[15:11] A[10] A[9:7] A[6:3] A[2:0] 0 ACT 0 0 1 1 0 0 00 0 0 0 0 - 1,2 D, D 1 0 0 0 0 0 00 0 0 0 0 - D, D 1 1 1 1 0 0 00 0 0 0 0 - 0 0 00000000 0 0 0 - Cycle Number Datab) Sub-Loop CKE CK, CK Table 4 - IDD1 Measurement-Loop Patterna) 0 3,4 ... nRCD ... nRAS Static High toggling ... repeat pattern 1...4 until nRCD - 1, truncate if necessary RD 0 1 0 1 0 0 00 0 0 repeat pattern 1...4 until nRAS - 1, truncate if necessary PRE 0 0 1 0 0 0 00 0 repeat pattern 1...4 until nRC - 1, truncate if necessary 1*nRC+0 ACT 0 0 1 1 0 0 00 0 0 F 0 - 1*nRC+1,2 D, D 1 0 0 0 0 0 00 0 0 F 0 - D, D 1 1 1 1 0 0 00 0 0 F 0 - 1*nRC+3,4 ... 1*nRC+nRCD ... 1*nRC+nRAS repeat pattern nRC + 1,...4 until nRC + nRCE - 1, truncate if necessary RD 0 1 0 1 0 0 00 0 0 F 0 00110011 repeat pattern nRC + 1,...4 until nRC + nRAS - 1, truncate if necessary PRE 0 0 1 0 0 0 00 0 0 F ... repeat pattern nRC + 1,...4 until *2 nRC - 1, truncate if necessary 1 2*nRC repeat Sub-Loop 0, use BA[2:0] = 1 instead 2 4*nRC repeat Sub-Loop 0, use BA[2:0] = 2 instead 3 6*nRC repeat Sub-Loop 0, use BA[2:0] = 3 instead 4 8*nRC repeat Sub-Loop 0, use BA[2:0] = 4 instead 5 10*nRC repeat Sub-Loop 0, use BA[2:0] = 5 instead 6 12*nRC repeat Sub-Loop 0, use BA[2:0] = 6 instead 7 14*nRC repeat Sub-Loop 0, use BA[2:0] = 7 instead 0 - a) DM must be driven LOW all the time. DQS, DQS are used according to RD Commands, otherwise MIDLEVEL. b) Burst Sequence driven on each DQ signal by Read Command. Outside burst operation, DQ signals are MID_LEVEL. Rev. 1.0 /Jul. 2012 43 Static High CS RAS CAS WE ODT BA[2:0] A[15:11] A[10] A[9:7] A[6:3] A[2:0] 0 D 1 0 0 0 0 0 0 0 0 0 0 - 1 D 1 0 0 0 0 0 0 0 0 0 0 - 2 D 1 1 1 1 0 0 0 0 0 F 0 - 3 D 1 1 1 1 0 0 0 0 0 F 0 - Cycle Number Command 0 toggling Datab) Sub-Loop CKE CK, CK Table 5 - IDD2N and IDD3N Measurement-Loop Patterna) 1 4-7 repeat Sub-Loop 0, use BA[2:0] = 1 instead 2 8-11 repeat Sub-Loop 0, use BA[2:0] = 2 instead 3 12-15 repeat Sub-Loop 0, use BA[2:0] = 3 instead 4 16-19 repeat Sub-Loop 0, use BA[2:0] = 4 instead 5 20-23 repeat Sub-Loop 0, use BA[2:0] = 5 instead 6 24-17 repeat Sub-Loop 0, use BA[2:0] = 6 instead 7 28-31 repeat Sub-Loop 0, use BA[2:0] = 7 instead a) DM must be driven LOW all the time. DQS, DQS are MID-LEVEL. b) DQ signals are MID-LEVEL. Command CS RAS CAS WE ODT BA[2:0] A[15:11] A[10] A[9:7] A[6:3] A[2:0] 0 D 1 0 0 0 0 0 0 0 0 0 0 - 1 D 1 0 0 0 0 0 0 0 0 0 0 - 2 D 1 1 1 1 0 0 0 0 0 F 0 - D 1 1 1 1 0 0 0 0 0 F 0 - Cycle Number Datab) Sub-Loop CKE CK, CK Table 6 - IDD2NT and IDDQ2NT Measurement-Loop Patterna) 0 Static High toggling 3 1 4-7 repeat Sub-Loop 0, but ODT = 0 and BA[2:0] = 1 2 8-11 repeat Sub-Loop 0, but ODT = 1 and BA[2:0] = 2 3 12-15 repeat Sub-Loop 0, but ODT = 1 and BA[2:0] = 3 4 16-19 repeat Sub-Loop 0, but ODT = 0 and BA[2:0] = 4 5 20-23 repeat Sub-Loop 0, but ODT = 0 and BA[2:0] = 5 6 24-17 repeat Sub-Loop 0, but ODT = 1 and BA[2:0] = 6 7 28-31 repeat Sub-Loop 0, but ODT = 1 and BA[2:0] = 7 a) DM must be driven LOW all the time. DQS, DQS are MID-LEVEL. b) DQ signals are MID-LEVEL. Rev. 1.0 /Jul. 2012 44 Command CS RAS CAS WE ODT BA[2:0] A[15:11] A[10] A[9:7] A[6:3] A[2:0] 0 RD 0 1 0 1 0 0 00 0 0 0 0 00000000 1 D 1 0 0 0 0 0 00 0 0 0 0 - 2,3 D,D 1 1 1 1 0 0 00 0 0 0 0 - 4 RD 0 1 0 1 0 0 00 0 0 F 0 00110011 D 1 0 0 0 0 0 00 0 0 F 0 - D,D 1 1 1 1 0 0 00 0 0 F 0 - Cycle Number Datab) Sub-Loop CKE CK, CK Table 7 - IDD4R and IDDQ4R Measurement-Loop Patterna) 0 Static High toggling 5 6,7 1 8-15 repeat Sub-Loop 0, but BA[2:0] = 1 2 16-23 repeat Sub-Loop 0, but BA[2:0] = 2 3 24-31 repeat Sub-Loop 0, but BA[2:0] = 3 4 32-39 repeat Sub-Loop 0, but BA[2:0] = 4 5 40-47 repeat Sub-Loop 0, but BA[2:0] = 5 6 48-55 repeat Sub-Loop 0, but BA[2:0] = 6 7 56-63 repeat Sub-Loop 0, but BA[2:0] = 7 a) DM must be driven LOW all the time. DQS, DQS are used according to RD Commands, otherwise MID-LEVEL. b) Burst Sequence driven on each DQ signal by Read Command. Outside burst operation, DQ signals are MID-LEVEL. 0, 0, 0, 0, 0, 0, 0, 1 1 1 1 1 1 = = = = = = = A[2:0] ODT 0 0 1 0 0 1 BA[2:0] BA[2:0] BA[2:0] BA[2:0] BA[2:0] BA[2:0] BA[2:0] A[6:3] 0 0 1 0 0 1 but but but but but but but WE CAS RAS CS 0 1 1 0 1 1 0 1 1 0 1 1 Sub-Loop Sub-Loop Sub-Loop Sub-Loop Sub-Loop Sub-Loop Sub-Loop A[9:7] WR D D,D WR D D,D repeat repeat repeat repeat repeat repeat repeat A[10] 1 2 3 4 5 6 7 1 2,3 4 5 6,7 8-15 16-23 24-31 32-39 40-47 48-55 56-63 A[15:11] 0 BA[2:0] 0 Command Cycle Number Sub-Loop CKE Static High toggling CK, CK Table 8 - IDD4W Measurement-Loop Patterna) Datab) 0 0 0 0 0 0 00 00 00 00 00 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 F F F 0 0 0 0 0 0 00000000 00110011 - 1 2 3 4 5 6 7 a) DM must be driven LOW all the time. DQS, DQS are used according to WR Commands, otherwise MID-LEVEL. b) Burst Sequence driven on each DQ signal by Write Command. Outside burst operation, DQ signals are MID-LEVEL. Rev. 1.0 /Jul. 2012 45 Command CS RAS CAS WE ODT BA[2:0] A[15:11] A[10] A[9:7] A[6:3] A[2:0] 0 0 REF 0 0 0 1 0 0 0 0 0 0 0 - 1 1.2 D, D 1 0 0 0 0 0 00 0 0 0 0 - D, D 1 1 1 1 0 0 00 0 0 F 0 - Cycle Number Datab) Sub-Loop CKE CK, CK Table 9 - IDD5B Measurement-Loop Patterna) 3,4 Static High toggling 5...8 2 repeat cycles 1...4, but BA[2:0] = 1 9...12 repeat cycles 1...4, but BA[2:0] = 2 13...16 repeat cycles 1...4, but BA[2:0] = 3 17...20 repeat cycles 1...4, but BA[2:0] = 4 21...24 repeat cycles 1...4, but BA[2:0] = 5 25...28 repeat cycles 1...4, but BA[2:0] = 6 29...32 repeat cycles 1...4, but BA[2:0] = 7 33...nRFC-1 repeat Sub-Loop 1, until nRFC - 1. Truncate, if necessary. a) DM must be driven LOW all the time. DQS, DQS are MID-LEVEL. b) DQ signals are MID-LEVEL. Rev. 1.0 /Jul. 2012 46 Table 10 - IDD7 Measurement-Loop Patterna) 2 3 4 Static High 5 6 7 8 9 10 4*nRRD nFAW nFAW+nRRD nFAW+2*nRRD nFAW+3*nRRD nFAW+4*nRRD 2*nFAW+0 2*nFAW+1 2&nFAW+2 11 2*nFAW+nRRD 2*nFAW+nRRD+1 2&nFAW+nRRD+2 12 13 2*nFAW+2*nRRD 2*nFAW+3*nRRD 14 2*nFAW+4*nRRD 15 16 17 18 3*nFAW 3*nFAW+nRRD 3*nFAW+2*nRRD 3*nFAW+3*nRRD 19 3*nFAW+4*nRRD 00110011 - 0 - 0 - 0 0 0 00110011 - 0 0 0 00000000 - 0 - 0 - A[10] 0 0 0 ODT 00000000 - WE 0 0 0 CAS ACT 0 0 1 1 0 0 00 0 0 0 RDA 0 1 0 1 0 0 00 1 0 0 D 1 0 0 0 0 0 00 0 0 0 repeat above D Command until nRRD - 1 ACT 0 0 1 1 0 1 00 0 0 F RDA 0 1 0 1 0 1 00 1 0 F D 1 0 0 0 0 1 00 0 0 F repeat above D Command until 2* nRRD - 1 repeat Sub-Loop 0, but BA[2:0] = 2 repeat Sub-Loop 1, but BA[2:0] = 3 D 1 0 0 0 0 3 00 0 0 F Assert and repeat above D Command until nFAW - 1, if necessary repeat Sub-Loop 0, but BA[2:0] = 4 repeat Sub-Loop 1, but BA[2:0] = 5 repeat Sub-Loop 0, but BA[2:0] = 6 repeat Sub-Loop 1, but BA[2:0] = 7 0 0 7 00 0 0 F D 1 0 0 Assert and repeat above D Command until 2* nFAW - 1, if necessary ACT 0 0 1 1 0 0 00 0 0 F RDA 0 1 0 1 0 0 00 1 0 F D 1 0 0 0 0 0 00 0 0 F Repeat above D Command until 2* nFAW + nRRD - 1 ACT 0 0 1 1 0 1 00 0 0 0 RDA 0 1 0 1 0 1 00 1 0 0 D 1 0 0 0 0 1 00 0 0 0 Repeat above D Command until 2* nFAW + 2* nRRD - 1 repeat Sub-Loop 10, but BA[2:0] = 2 repeat Sub-Loop 11, but BA[2:0] = 3 D 1 0 0 0 0 3 00 0 0 0 Assert and repeat above D Command until 3* nFAW - 1, if necessary repeat Sub-Loop 10, but BA[2:0] = 4 repeat Sub-Loop 11, but BA[2:0] = 5 repeat Sub-Loop 10, but BA[2:0] = 6 repeat Sub-Loop 11, but BA[2:0] = 7 D 1 0 0 0 0 7 00 0 0 0 Assert and repeat above D Command until 4* nFAW - 1, if necessary RAS Datab) CS A[9:7] A[15:11] BA[2:0] Command A[2:0] 1 0 1 2 ... nRRD nRRD+1 nRRD+2 ... 2*nRRD 3*nRRD A[6:3] 0 toggling Cycle Number Sub-Loop CKE CK, CK ATTENTION! Sub-Loops 10-19 have inverse A[6:3] Pattern and Data Pattern than Sub-Loops 0-9 a) DM must be driven LOW all the time. DQS, DQS are used according to RD Commands, otherwise MID-LEVEL. b) Burst Sequence driven on each DQ signal by Read Command. Outside burst operation, DQ signals are MID-LEVEL. Rev. 1.0 /Jul. 2012 47 IDD Specifications (Tcase: 0 to 95oC) * Module IDD values in the datasheet are only a calculation based on the component IDD spec. The actual measurements may vary according to DQ loading cap. 2GB, 256M x 64 SO-DIMM: HMT425S6MFR6C Symbol IDD0 IDD1 IDD2N IDD2NT IDD2P0 IDD2P1 IDD2Q IDD3N IDD3P IDD4R IDD4W IDD5B IDD6 IDD6ET IDD7 DDR3 1066 220 280 100 120 80 88 100 140 100 500 540 560 88 100 840 DDR3 1333 240 300 120 140 80 88 120 140 100 600 620 580 88 100 940 DDR3 1600 240 300 120 140 80 88 120 140 100 700 720 580 88 100 900 Unit mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA note DDR3 1600 680 760 480 640 192 240 480 640 240 1080 1120 1600 192 240 1400 Unit mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA note 4GB, 512M x 64 SO-DIMM: HMT451S6MFR8C Symbol IDD0 IDD1 IDD2N IDD2NT IDD2P0 IDD2P1 IDD2Q IDD3N IDD3P IDD4R IDD4W IDD5B IDD6 IDD6ET IDD7 Rev. 1.0 /Jul. 2012 DDR3 1066 560 640 400 560 192 240 400 480 240 840 880 1520 192 240 1080 DDR3 1333 640 720 480 640 192 240 480 560 240 1000 1024 1560 192 240 1320 48 8GB, 1G x 64 SO-DIMM: HMT41GS6MFR8C Symbol IDD0 IDD1 IDD2N IDD2NT IDD2P0 IDD2P1 IDD2Q IDD3N IDD3P IDD4R IDD4W IDD5B IDD6 IDD6ET IDD7 Rev. 1.0 /Jul. 2012 DDR3 1066 960 1040 800 1120 384 480 800 960 480 1240 1280 1920 384 480 1480 DDR3 1333 1120 1200 960 1280 384 480 960 1120 480 1480 1504 2040 384 480 1800 DDR3 1600 1320 1400 960 1280 384 480 960 1280 480 1720 1760 2240 384 480 2040 Unit mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA note 49 Module Dimensions 256Mx64 - HMT425S6MFR6C Front Side 67.60mm 2.40mm max 2.0 30.0mm 4.00 0.10 Detail-A pin 1 pin 203 21.00 2.15 2 X 1.80 0.10 20.0mm 6.00 SPD 1.00 0.08 mm 39.00 1.65 0.10 3.00 Back 2.55 0.3 0.15 4.00 0.10 Detail of Contacts A 0.3~1.0 0.45 0.03 0.60 1.00 0.05 Note: 1. 0.13 tolerance on all dimensions unless otherwise stated. Units: millimeters Rev. 1.0 /Jul. 2012 50 512Mx64 - HMT451S6MFR8C Front Side 67.60mm 3.50mm max 2.0 30.0mm 4.00 0.10 Detail-A pin 1 pin 203 21.00 2.15 2 X 1.80 0.10 20.0mm 6.00 SPD 1.00 0.08 mm 39.00 1.65 0.10 3.00 Back 2.55 0.3 0.15 4.00 0.10 Detail of Contacts A 0.3~1.0 0.45 0.03 0.60 1.00 0.05 Note: 1. 0.13 tolerance on all dimensions unless otherwise stated. Units: millimeters Rev. 1.0 /Jul. 2012 51 1Gx64 - HMT41GS6MFR8C Front Side 67.60mm 3.50mm max 2.0 Detail-B pin 1 pin 203 21.00 1.65 0.10 2.15 2 X 1.80 0.10 20.0mm Detail- A 6.00 30.0mm 4.00 0.10 1.00 0.08 mm 39.00 3.00 Back SPD 2.55 0.3 0.15 4.00 0.10 Detail of Contacts A 0.3~1.0 0.45 0.03 0.60 1.00 0.05 Note: 1. 0.13 tolerance on all dimensions unless otherwise stated. Units: millimeters Rev. 1.0 /Jul. 2012 52