HY SS12L

SS12L thru SS110L
SURFACE MOUNT
REVERSE VOLTAGE - 20 to 100 Volts
SCHOTTKY BARRIER RECTIFIERS
FORWARD CURRENT - 1.0 Ampere
FEATURES
SOD-123FL
●Low profile package
●Ideal for automated placement
.114(2.9)
.098(2.5)
●Ultrafast reverse recovery time
●Low forward voltage drop
.077(1.95)
.061(1.55)
●Low power losses, high efficiency
.039(1.0)
.024(0.6)
●High surge capability
●High temperature soldering:
260℃/10 seconds at terminals
●Component in accordance to
RoHS 2002/95/1 and WEEE 2002/96/EC
.047(1.2)
.031(0.8)
MECHANICAL DATA
●Case: JEDEC SOD-123FL molded plastic
body over passivated chip
.043(1.1)
.020(0.5)
.154(3.9)
.138(3.5)
.010(0.25)
.002(0.05)
●Terminals: Solder plated, solderable per
J-STD-002B and JESD22-B102D
●Polarity: Laser band denotes cathode end
● Weight: 0.017gram
.004(0.1)max
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave ,60Hz, resistive or inductive load.
For capacitive load, derate current by 20%
SYMBOL
SS12L
SS13L
SS14L
SS15L
SS16L
SS18L
SS110L
MARKING
S12L
S13L
S14L
S15L
S16L
S18L
S110L
Maximum Recurrent Peak Reverse Voltage
VRRM
20
30
40
50
60
80
100
V
Maximum RMS Voltage
VRMS
14
21
28
35
42
56
70
V
VDC
20
30
40
50
60
80
100
V
CHARACTERISTICS
Maximum DC Blocking Voltage
Maximum Average Forward
Rectified Current
Peak Forward Surge Current
@TL=100 ℃
8.3ms Single Half Sine-Wave
UNIT
I(AV)
1.0
A
IFSM
30
A
Super Imposed On Rated Load (JEDEC Method)
Maximum Forward Voltage at 1.0A DC
@TA=25℃
at Rated DC Blocking Voltage
@TA=100℃
Thermal resistance from junction to ambient (Note1)
Operating Temperature Range
Storage Temperature Range
0.55
VF
Maximum DC Reverse Current
0.70
1.0
IR
10
0.85
V
mA
RθJA
88
℃/W
TJ
-55 to + 150
℃
TSTG
-55 to + 150
℃
Note1: Mounted on FR-4 P.C.B. With 0.9x1.5 mm copper pad areas (≈35 μm thick)
REV. 1, 30-Dec-2011
~ 200 ~
RATING AND CHARACTERTIC CURVES
SS12L thru SS110L
FIG. 2 – MAXIMUM NON-REPETITIVE SURGE CURRENT
FIG. 1 - FORWARD CURRENT DERATING CURVE
PEAK FORWARD SURGE CURRENT,
(AMPERES)
AVERAGE FORWARD CURRENT
(AMPERES)
1.00
0.75
0.50
SINGLE PHASE
HALF WAVE 60Hz
RESISTIVE OR
INDUCTIVE LOAD
0.25
0
25
50
75
100
125
150
40
30
20
10
PULSE WIDTH 8.3mS
SINGLE HALF-SINE-WAVE
(JEDEC METHOD)
0
1
175
2
5
LEAD TEMPERATURE ℃
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.3-TYPICAL FORWARD CHARACTERISTICS
FIG.4-TYPICAL REVERSE CHARACTERISTICS
20
100
SS12L-SS14L
SS15L-SS16L
SS18L-SS110L
1.0
T J = 25°C
PULSE WIDTH 300us
1% DUTY CYCLE
0.1
0
0.1
0.3
0.5
0.7
0.9
1.1
1.3
1.5
1.7
INSTANTANEOUS REVERSE CURRENT, (mA )
INSTANTANEOUS FORWARD CURRENT,
(A)
10
T J=100℃
10
1.0
0.1
T J=25℃
0.01
0.001
0
20
40
60
80
100
INSTANTANEOUS FORWARD VOLTAGE, (VOLTS)
PERCENT OF RATED PEAK REVERSE VOLTAGE,(%)
REV. 1, 30-Dec-2011
~ 201 ~