KINGTRONICS FR107

Website: www.kingtronics.com
Email: [email protected]
Tel: (852) 8106 7033
Fax: (852) 8106 7099
FR101 THRU FR107
FAST RECOVERY RECTIFIERS
Reverse Voltage - 50 to 1000 Volts Forward Current - 1.0 Ampere
FEATURES
◆The plastic package carries Underwriters Laboratory Flammability Classification 94V-0
◆Fast switching for high efficiency
◆Low reverse leakage
◆High forward surge current capability
◆High temperature soldering guaranteed:
◆250℃/10 seconds,0.375”(9.5mm) lead length,5 lbs. (2.3kg) tension
MECHANICAL DATA
Case: JEDEC DO-41 molded plastic body
Terminals: Plated axial leads, solderable per MIL-STD-750,Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight:0.012 ounce, 0.33 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25℃ ambient temperature unless otherwise specified.
Single phase half-wave 60Hz,resistive or inductive load,for capacitive load current derate by 20%.
FR
FR
FR
FR
FR
FR
FR
101
102
103
104
105
106
107
UNITS
SYMBOLS
Maximum repetitive peak reverse voltage
VRRM
50
100
200
400
600
800
1000
VOLTS
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
VOLTS
VDC
50
100
200
400
600
800
1000
VOLTS
Maximum DC Blocking Voltage
Maximum average forward rectified current
0.375”(9.5mm) lead length at TA=75℃
I(AV)
1.0
Amp
IFSM
30.0
Amps
VF
1.3
Volts
Peak forward surge current
8.3ms single half sine-wave superimposed on
rated load (JEDEC Method)
Maximum instantaneous forward voltage at 1.0A
Maximum DC reverse current TA=25℃
5.0
IR
at rated DC blocking voltage TA=100℃
mA
50.0
Maximum reverse recovery time (NOTE 1)
trr
Typical junction capacitance (NOTE 2)
CJ
15.0
pF
RθJA
50.0
℃/W
TJ,TSTG
-65 to +150
℃
Typical thermal resistance (NOTE 3)
Operating junction and storage temperature range
150
250
500
ns
Note: 1.Reverse recovery condition IF=0.5A,IR=1.0A,Irr=0.25A
2.Measured at 1MHz and applied reverse voltage of 4.0V D.C.
3.Thermal resistance from junction to ambient at 0.375”(9.5mm)lead length,P.C.B. mounted
1
Website: www.kingtronics.com
Email: [email protected]
Tel: (852) 8106 7033
Fax: (852) 8106 7099
FR101 THRU FR107
RATINGS AND CHARACTERISTIC CURVES FR101 THRU FR107
Note: Specifications are subject to change without notice.
2