BT137-600E Sensitive Gate Triacs Description Passivated, sensitive gate triacs in a plastic envelope, intended for use in general purpose bidirectional switching and phase control applications, where high sensitivity is required in all four quadrants. Simplified outline Symbol Applications: T1 T2 Motor control Industrial and domestic lighting G 3 Heating TO-220 Static switching Description Pin 1 Main terminal 1 (T1) 2 Main terminal 2 (T2) Blocking voltage to 600 V 3 gate (G) On-state RMS current to 8 A TAB Main terminal 2 (T2) SYMBOL V DRM IT 12 Value Unit 600 V 8 A 65 A RMS on-state current Non-repetitive peak on-state current I TSM SYMBOL R th j-a PARAMETER Repetitive peak off-state voltages RMS R th j-mb Features PARAMETER Thermal resistance Junction to mounting base Thermal resistance Junction to ambient http://www.luguang.cn MIN TYP Full cycle - Half cycle In free air CONDITIONS MAX UNIT - 2.0 K/W - - 2.4 K/W - 60 - K/W mail:[email protected] BT137-600E Sensitive Gate Triacs Limiting values in accordance with the Maximum system(IEC 134) SYMBOL PARAMETER V DRM Repetitive peak off-state Voltages I T(RMS) RMS on-state current Non-repetitive surge peak on-statecurrent I TSM I 2t for fusing 2 It Repetitive rate of rise of on-state current after triggering dI T/dt MIN Value UNIT - 600 V - 8 A 65 A t=16.7ms - 71 21 A A 2S T2+G+ T2+G- - 50 A/ s CONDITIONS Full sine wave;T mb 102 full sine wave;, T j =25 prior to surge T=10ms I TM=12A; I G=0.2A; DI G/dt=0.2A/ s t=20ms T2-GT2-G+ I GM Peak gate current V GM Peak gate voltage P GM Peak gate power P G(AV) Average gate power T stg Tj 50 A/ s 50 A/ s 10 A/ s 2 A 5 V - 5 W 0.5 W Storage temperature -40 150 Operating junction Temperature - 125 Over any 20 ms period O T J=25 C unless otherwise stated SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNIT Static characteristics I GT1 Gate trigger current V D=12V; I T=0.1A IL Latching current V D=12V; I GT=0.1A IH VT Holding current On-state voltage V GT Gate trigger voltage ID Off-state leakage current T2+G+ T2+GT2-GT2-G+ - 2.5 4.0 5.0 11 10 10 10 25 mA mA mA mA T2+G+ T2+GT2-GT2-G+ - 25 35 25 35 20 1.65 mA mA mA mA mA - 3.0 14 3.0 4.0 2.5 1.3 0.25 0.7 0.4 1.5 - V V - 0.1 0.5 mA V/ s V D=12V; I GT=0.1A I T=10A V D=12V;I T=0.1A V D=400V;I T=0.1A;T J=125 V D=V DRM(max);T J=125 V Dynamic Characteristics dV D/dt Critical rate of rise of Off-state voltage V DM=67% V DRM(max);Tj=125 ; Exponential wave form;gate open circuit - 50 - t gt Gate controlled turn-on time I TM=12A;V D=V DRM(max);I G=0.1A; Dl G/dt=5A/ s - 2 - http://www.luguang.cn mail:[email protected] s BT137-600E Sensitive Gate Triacs Description http://www.luguang.cn mail:[email protected] BT137-600E Sensitive Gate Triacs Description http://www.luguang.cn mail:[email protected] BT137-600E Sensitive Gate Triacs MECHANICAL DATA Dimensions in mm Net Mass: 2 g 1/4 http://www.luguang.cn mail:[email protected]