LUGUANG BT137-600E

BT137-600E
Sensitive Gate Triacs
Description
Passivated, sensitive gate triacs in a plastic envelope, intended for use in general purpose
bidirectional switching and phase control applications, where high sensitivity is required in all
four quadrants.
Simplified outline
Symbol
Applications:
T1
T2
Motor control
Industrial and domestic lighting
G
3
Heating
TO-220
Static switching
Description
Pin
1
Main terminal 1 (T1)
2
Main terminal 2 (T2)
Blocking voltage to 600 V
3
gate (G)
On-state RMS current to 8 A
TAB
Main terminal 2 (T2)
SYMBOL
V DRM
IT
12
Value
Unit
600
V
8
A
65
A
RMS on-state current
Non-repetitive peak on-state current
I TSM
SYMBOL
R th j-a
PARAMETER
Repetitive peak off-state voltages
RMS
R th j-mb
Features
PARAMETER
Thermal resistance
Junction to mounting base
Thermal resistance
Junction to ambient
http://www.luguang.cn
MIN
TYP
Full cycle
-
Half cycle
In free air
CONDITIONS
MAX
UNIT
-
2.0
K/W
-
-
2.4
K/W
-
60
-
K/W
mail:[email protected]
BT137-600E
Sensitive Gate Triacs
Limiting values in accordance with the Maximum system(IEC 134)
SYMBOL
PARAMETER
V DRM
Repetitive peak off-state
Voltages
I T(RMS)
RMS on-state current
Non-repetitive surge
peak on-statecurrent
I TSM
I 2t for fusing
2
It
Repetitive rate of rise of
on-state current after
triggering
dI T/dt
MIN
Value
UNIT
-
600
V
-
8
A
65
A
t=16.7ms
-
71
21
A
A 2S
T2+G+
T2+G-
-
50
A/ s
CONDITIONS
Full sine wave;T mb 102
full sine wave;,
T j =25
prior to surge
T=10ms
I TM=12A; I G=0.2A;
DI G/dt=0.2A/ s
t=20ms
T2-GT2-G+
I GM
Peak gate current
V GM
Peak gate voltage
P GM
Peak gate power
P G(AV)
Average gate power
T stg
Tj
50
A/ s
50
A/ s
10
A/ s
2
A
5
V
-
5
W
0.5
W
Storage temperature
-40
150
Operating junction
Temperature
-
125
Over any 20 ms period
O
T J=25 C unless otherwise stated
SYMBOL PARAMETER
CONDITIONS
MIN
TYP MAX UNIT
Static characteristics
I GT1
Gate trigger current
V D=12V; I T=0.1A
IL
Latching current
V D=12V; I GT=0.1A
IH
VT
Holding current
On-state voltage
V GT
Gate trigger voltage
ID
Off-state leakage current
T2+G+
T2+GT2-GT2-G+
-
2.5
4.0
5.0
11
10
10
10
25
mA
mA
mA
mA
T2+G+
T2+GT2-GT2-G+
-
25
35
25
35
20
1.65
mA
mA
mA
mA
mA
-
3.0
14
3.0
4.0
2.5
1.3
0.25
0.7
0.4
1.5
-
V
V
-
0.1
0.5
mA
V/ s
V D=12V; I GT=0.1A
I T=10A
V D=12V;I T=0.1A
V D=400V;I T=0.1A;T J=125
V D=V DRM(max);T J=125
V
Dynamic Characteristics
dV D/dt
Critical rate of rise of
Off-state voltage
V DM=67% V DRM(max);Tj=125 ;
Exponential wave form;gate open circuit
-
50
-
t gt
Gate controlled turn-on
time
I TM=12A;V D=V DRM(max);I G=0.1A;
Dl G/dt=5A/ s
-
2
-
http://www.luguang.cn
mail:[email protected]
s
BT137-600E
Sensitive Gate Triacs
Description
http://www.luguang.cn
mail:[email protected]
BT137-600E
Sensitive Gate Triacs
Description
http://www.luguang.cn
mail:[email protected]
BT137-600E
Sensitive Gate Triacs
MECHANICAL DATA
Dimensions in mm
Net Mass: 2 g
1/4
http://www.luguang.cn
mail:[email protected]