LGE R4003(433.920MHz) SAW Resonator Features 1-port Resonator Provides reliable, fundamental mode, quartz frequency stabilization i.e. in transmitters or local oscillators Surface Mounted Technology (SMT) Lead-free production and RoHS compliance Package Dimensions Ceramic Package: QCC4A Marking Pin Configuration 1 Input / Output 3 Output / Input 2/4 Case Ground Sign Data (unit: mm) Sign Data (unit: mm) A 1.2 D 1.4 B 0.8 E 5.0 C 0.5 F 3.5 Equivalent LC Model Top View, Laser Marking LGE R4003 "LGE”: Manufacturer’s mark Laser Marking “R”: SAW resonator “4003”: Part number 1 2 2009 A B C D 2010 N P Q R 2011 a b c d 2012 n p q r Code 3 4 5 6 7 8 9 10 E F G S T U e f s t 11 12 H J V W K L M X Y Z g h i j k m u v w x y z Maximum Ratings Rating Value Unit P 0 dBm DC voltage between any terminals VDC ±30 V Operating temperature range TA -40 ~ +85 °C Storage temperature range Tstg -40 ~ +85 °C CW RF power dissipation LGE R4003(433.920MHz) SAW Resonator Electrical Characteristics Characteristic Center Frequency (+25℃) Absolute Frequency Temperature Stability Frequency Aging Minimum fC 433.845 4. 5. Unit 433.995 MHz IL 1.5 Unloaded Q QU 9,000 50 Loaded Q QL 1,500 Turnover Temperature T0 Turnover Frequency f0 fC kHz Frequency Temperature Coefficient FTC 0.032 ppm/℃2 Absolute Value during the First Year fA ≤10 ppm/yr 25 kHz 2.0 dB 55 ℃ 1.0 M RM 19 Motional Inductance LM 65.5042 H Motional Capacitance CM 2.0559 fF Shunt Static Capacitance C0 1.9 2.2 26 Motional Resistance RoHS Compliant 1. 2. 3. Maximum ±75 DC Insulation Resistance Between Any Two Terminals RF Equivalent RLC Model Typical fC Tolerance from 433.920 MHz Insertion Loss Quality Factor Sym 2.5 pF Electrostatic Sensitive Device Unless noted otherwise, case temperature TC = +25°C±2°C. The center frequency, fC, is measured at the minimum insertion loss point with the resonator in the 50Ω test system. Frequency aging is the change in fC with time and is specified at +65°C or less. Aging may exceed the specification for prolonged temperatures above +65°C. Typically, aging is greatest the first year after manufacture, decreasing in subsequent years. Turnover temperature, TO, is the temperature of maximum (or turnover) frequency, fO. The nominal frequency at any case 2 temperature, TC, may be calculated from: f = fO [1 - FTC (TO - TC) ]. This equivalent RLC model approximates resonator performance near the resonant frequency and is provided for reference only. The capacitance CO is the static capacitance between the two terminals measured at low frequency (10MHz) with a capacitance meter. The measurement includes case parasitic capacitance. Test Circuit Temperature Characteristics LGE R4003(433.920MHz) SAW Resonator Typical Frequency Response Typical Application Circuits 1) Low-Power Transmitter Application 2) Local Oscillator Application LGE R4003(433.920MHz) SAW Resonator Stability Characteristics Test item Condition of test 1 Mechanical shock (a) Drops: 3 times on concrete floor (b) Height: 1.0 m 2 Vibration resistance (a) Frequency of vibration: 10~55Hz (c) Directions: X,Y and Z (b) Amplitude: 1.5 mm (d) Duration: 2 hours 3 Moisture resistance (a) Condition: 40°C, 90~95% R.H. (c) Wait 4 hours before measurement (b) Duration: 96 hours 4 Climatic sequence (a) +70°C for 16 hours (b) +55°C for 24 hours, 90~95% R.H. (c) -25°C for 2 hours (d) +40°C for 24 hours, 90~95% R.H. (e) Wait 4 hours before measurement 5 High temperature exposure (a) Temperature: 70°C (c) Wait 4 hours before measurement 6 Thermal impact (a) +70°C for 30 minutes -25°C for 30 minutes repeated 3 times (b) Wait 4 hours before measurement (b) Duration: 250 hours Requirements: The SAW resonator shall remain within the electrical specifications after tests. Remarks SAW devices should not be used in any type of fluid such as water, oil, organic solvent, etc. Be certain not to apply voltage exceeding the rated voltage of components. Do not operate outside the recommended operating temperature range of components. Sudden change of temperature shall be avoided, deterioration of the characteristics can occur. Be careful of soldering temperature and duration of components when soldering. Do not place soldering iron on the body of components. Be careful not to subject the terminals or leads of components to excessive force. SAW devices are electrostatic sensitive. Please avoid static voltage during operation and storage. Ultrasonic cleaning shall be avoided. Ultrasonic vibration may cause destruction of components.