Aluminum Electrolytic Capacitors NS Series (No Sparks with DC Overvoltage) MERITEK FEATURES No sparks with specified DC overvoltage applied. Withstanding 2000 hours application of rate ripple current at 105°C. SPECIFICATIONS Item Characteristic Operating Temp Range - 25 ~ +105C Rated Working Voltage 200 ~ 400VDC Capacitance Tolerance (120Hz 20C) 20%(M) I 0.06CV + 10 (A) Leakage Current I : Leakage Current (A) C : Rated Capacitance(F) V : Working Voltage (V) (20C) *After 2 minutes Surge Voltage W.V. 200 400 (20C) S.V. 250 450 Dissipation Factor ( tan ) (120Hz 20C) W.V. 200 400 tan 0.15 0.24 Low Temperature Stability Impedance ratio at 120Hz Rated Voltage (V) -25C / +20C Load Life 200 400 4 6 After 2000 hours application of W.V. and +105C ripple current value , the capacitor shall meet the following limits. ( DC + ripple peak voltage rated working voltage ) Shelf Life Capacitance Change 20% of initial. Dissipation Factor 200% of initial specified value Leakage Current initial specified value At +105C no voltage application after 1000 hours the capacitor shall meet the limits for load life characteristics. ( with voltage treatment ) PART NUMBER SYSTEM DIMENSIONS (mm) NS 50V 220 M TA 16x25 Meritek Series Rated Voltage Rated Capacitance Express in micro farad(uF), First two digits are significant figures, Third digit denotes number of zeros. ‘R’ denotes decimal point for values less than 10uF Tolerance M - 20% Package Code TA Tape & Ammo TR Tape & Reel Blank Case size – (D) Diameter x (L) Length in mm (Optional) D F d a 16 7.5 0.8 1.5 18 7.5 0.8 1.5 Rev. 7 NS Series Aluminum Electrolytic Capacitors (No Sparks with DC Overvoltage) MERITEK RIPPLE CURRENT COEFFICIENTS Frequency(Hz) W.V. 200V 400V 60 120 0.80 0.75 1.00 1.00 1k Multiplier 1.30 1.50 10k 100k 1.40 1.75 1.60 1.85 Temperature(C) 65 85 105 Multiplier 1.80 1.50 1.00 CASE SIZE & MAX RIPPLE CURRENT Case size Max. ripple current V Cap. (uF) Item 22 33 200 R.C. 16x25 16x31.5 18x25 16x31.5 18x25 16x40 18x31.5 18x35.5 18x40 400 480 470 540 520 660 630 730 770 47 56 120 150 180 220 (mm) 105C 120Hz 400 DxL 39 68 82 100 : DxL : mA(rms) DxL 16x25 16x25 16x31.5 18x25 16x31.5 16x40 18x31.5 18x35.5 18x40 R.C. 170 210 260 250 280 340 330 380 440 DC OVERVOLTAGE TEST CONDITION The vent will be operated and the capacity shall become an open circuit without burning the material when the following excess DC voltage is applied. Rated 200 VDC 400 VDC Current 4A 2A Test DC voltage 300/375 VDC 500/600 VDC AC input SW Cx + - Constant DC voltage/current power supply Rev. 7