NI NIPCIE-1430

Dual-Channel Camera Link Image Acquisition
NI PCIe-1430
• High-resolution, high-speed image
acquisition for up to two base
configuration Camera Link cameras
• Onboard programmable region
of interest
• RTSI bus synchronization with data
acquisition, motion, and CAN
• Additional I/O available through the
NI Camera Link I/O Extension Board
Operating Systems
• Windows Vista/XP/2000
Recommended Software
•
•
•
•
•
LabVIEW
LabWindows™/CVI
Measurement Studio
Vision Development Module
Vision Builder AI
Driver Software (included)
• Vision Acquisition
Overview and Applications
The National Instruments PCIe-1430 image acquisition board works with
up to two base configuration Camera Link cameras and is used by
machine and scientific imaging developers who need high-throughput
digital imaging at a lower cost.
Camera Link
Camera Link is an industrial high-speed serial data and cabling standard
developed by National Instruments, camera vendors, and other image
acquisition companies. Created for easy connectivity between the PC
and the camera, Camera Link provides simple, flexible cabling for highspeed, high-resolution digital cameras. A Camera Link cable, a slender
26-pin cable with 24-bit data and clock, enables as well as controls
signals. You can control camera functionality by asynchronous serial
control or LVDS differential lines through a Camera Link cable. Camera
Link offers future data rate capabilities up to 2.3 Gb/s. You can
interchange Camera Link digital cameras from a variety of vendors with
Camera Link image acquisition hardware.
Digital I/O
Each NI PCIe-1430 includes one trigger line and two Camera Link
connectors that work with any base configuration Camera Link camera.
Additional I/O lines for advanced triggering, pulse-train outputs, and
Figure 1. Camera Link is a popular interface for high-resolution and high-speed cameras.
isolated digital I/O also are available with the NI Camera Link I/O
Extension Board. Use the serial interface on the Camera Link connector
to easily configure and control the camera with NI Vision Acquisition
software and Measurement & Automation Explorer (MAX) configuration
software. With this board, you can use the advanced triggering available
to send strobe pulses and pulse trains.
PCI Express
With the four-lane PCI Express configuration of the NI PCIe-1430, you
can acquire from two base configuration Camera Link cameras at their
maximum bandwidths without onboard memory. This data is streamed
directly to PC memory so it can be processed along with synchronized
data acquisition and/or motion.
Dual-Channel Camera Link Image Acquisition
Synchronize Vision, Data Acquisition,
and Motion
Ordering Information
Using the RTSI bus, you can develop applications for which vision, data
acquisition, and motion are tightly integrated. With the NI PCIe-1430,
you can route digital timing lines such as acquisition in progress or
frame start across the RTSI bus to control the timing of your machine
vision application.
Includes Vision Acquisition software.
Camera Compatibility
The NI PCIe-1430 works with base configuration Camera Link cameras
from Sony, Basler, and other camera manufacturers. Visit
ni.com/camera for a current list of compatible cameras.
NI PCIe-1430..........................................................................779479-01
Accessories
NI Camera Link I/O Extension Board ....................................779352-01
Camera Link cable (2 m)........................................................187676-02
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/vision.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
Dual-Channel Camera Link Image Acquisition
Specifications
The following specifications apply to the NI PCIe-1430 image acquisition
board. These specifications are typical at 25 °C, unless otherwise stated.
External Connections
Number of external
trigger I/O lines .............................. 1
Note: External TTL lines on the 15-pin D-Sub connector become
unavailable when the trigger source is set as an optically isolated input
or an RS422 input in MAX.
External trigger lines
Voltage range .................................
VIH min .......................................
VIL max .......................................
VOH min .....................................
VOL max .....................................
Polarity............................................
0 to 5 V (TTL)
2.0 V
0.8 V
2.4 V at 8 mA source
0.55 V at 8 mA sink
Programmable, active high or
active low
Power-on state.................................... Input (high-impedance) 22.1 kΩ
pull-down to ground
Camera interface ................................ Camera Link 1.1
Clocks
Pixel clock frequency range ................ 20 to 85 MHz1
Note: The Camera Link specification requires cameras to transmit at a
minimum of 20 MHz.
1This
value corresponds to the serialized Camera Link cable transmission rate of
140 to 595 MHz.
PCI Express Interface
Environment
The NI PCIe-1430 is intended for indoor use only.
Operating temperature ....................... 0 to 40 °C1
Storage temperature........................... -20 to 70 °C
Relative humidity ................................ 5 to 90%, noncondensing
Pollution degree.................................. 2
Approved at altitudes up to 2,000 m.
1This
temperature value was determined through testing the device in a Dell Precision 470
workstation with two adjacent plug-in devices each dissipating 11.6 W.
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA 61010-1
Note: For UL and other safety considerations, refer to the product label,
or visit ni.com/certification, search by model number or product line,
and click the appropriate link in the Certification column.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following
standards of EMC for electrical equipment for measurement, control, and
laboratory use:
• EN 61326 EMC requirements; Minimum Immunity
• EN 55011 Emissions; Group 1, Class A
• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note: For EMC compliance, operate this device according to product
documentation.
PCI Express compliance ...................... Version 1.0a
Native link width................................. x4
Up-plugging link width availability..... x8, x16
CE Compliance
Note: Some system devices limit data transfer rates for plug-in devices
in an up-plugging configuration. Refer to the documentation provided by
your computer manufacturer to determine if your computer will support
a x4 plug-in device at a x4 data rate in a larger slot.
• 73/23/EEC; Low-Voltage Directive (safety)
• 89/336/EEC; Electromagnetic Compatibility Directive (EMC)
Serial Interface
Baud rates supported.......................... 300, 600, 1200, 1800, 2000,
2400, 3600, 4800, 7200, or
9600 b/s; 19.2, 38.4, 56, or
115.2 kb/s
Power Requirements
Voltage ................................................ +12 V (1.25 A)1
1If
you are using special firmware add-ons, this value is subject to change. Consult your
firmware upgrade documentation for specific requirements.
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
Note: Refer to the Declaration of Conformity (DoC) for this product for
any additional regulatory compliance information. To obtain the DoC for
this product, visit ni.com/certification, search by model number or
product line, and click the appropriate link in the Certification column.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers
At the end of their life cycle, all products must be sent to a WEEE
recycling center.
For more information about WEEE recycling centers and National
Instruments WEEE initiatives, visit ni.com/environment/weee.htm.
Physical Characteristics
Dimensions.......................................... 10.7 by 17.5 cm
(4.2 by 6.9 in.)
Weight................................................. 205 g (7.23 oz)
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional Services
Our Professional Services Team is composed of NI applications engineers,
NI Consulting Services, and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range from
start-up assistance to turnkey
system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
ni.com • 800 813 3693
National Instruments • [email protected]
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
*351482A-01*
351482A-01
2007-8606-221-101-D
© 2007 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI,
ni.com, RTSI, and SCXI are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Other product and company
names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no
agency, partnership, or joint-venture relationship with NI.