POWEREX VLA106

VLA106-24151
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
Isolated
DC/DC Converter
A
B
24151
XXXX
J
L
K
G
+VIN
8
E
H
D
1
G
11
FILTER
C
F
3 VO
FILTER
9
CONSTANT
VOLTAGE
CIRCUIT
2 NC
1 -VO
DRIVE
CIRCUIT
OVER-CURRENT
PROTECTION
–VIN
10
11
OPTOCOUPLER
Test Circuit Diagram
3
8
VIN
+ 100µF
50V
9
VLA106-24151
2
10
11
Outline Drawing and Circuit Diagram
Dimensions
Inches
Millimeters
A
1.3
33.0
B
0.945
24.0
C
0.71
18.0
D
1.0
25.4
E
0.22
5.5
F
0.53
13.5
G
0.18
4.5
H
0.10
2.54
J
0.18±0.06
4.5±1.5
K 0.02+0.004/-0.002 0.5+0.1/-0.05
L
0.01+0.01/-0.002 0.25+0.2/-0.05
1
47µF
50V
+
LOAD
Description:
VLA106-24151 is a DC-DC
converter. Its output power is
1.5W and the input is isolated
from the output. The over-current
protection circuit is built-in. This
device is used for on-board power
supplies in industrial control
equipment.
Features:
£ Input Voltage Range:
21.6 to 26.4V DC
£ Output: +15V, 100mA
(Output Power: 1.5W)
£ Thin Profile, Lightweight Design
£ Electrical Isolation Voltage
Between Input and Output:
2500 Vrms for 1 Minute
£ Built in Over-current Protection
Circuit
Application:
On-board power supplies such as
industrial equipment and control
equipment.
Note: All dimensions listed are maximums except D.
Rev. 01/10
1
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
VLA106-24151
Isolated DC/DC Converter
Absolute Maximum Ratings, Ta = 25°C unless otherwise specified
Characteristics
Symbol
VLA106-24151
Units
Input Voltage (Between Pins 8, 9, and 10, 11)
VIN
27
Volts
Output Current (Between Pins 3 and 1)
IO
100
mA
°C
Operating Temperature (No Condensation)*
Topr
-20 ~ 70
Storage Temperature (No Condensation)
Tstg
-20 to 85
°C
Input-Output Isolation Voltage (AC, 1 Minute)
VISO
2500
Vrms
*Please refer to derating characteristics.
Electrical and Mechanical Characteristics, Ta = 25°C, VIN = 24V unless otherwise specified
Characteristics
Symbol
Input Voltage
VIN
Output Voltage
Test Conditions
Typ.
Max.
Units
Recommended Range
21.6
24.0
26.4
Volts
Max Operating Range
18.0
—
26.4
Volts
VO
IO = 0 ~ 100mA
14.25
15.0
15.75
Volts
Input Regulation
Reg-I
IO = 0 ~ 100mA, VIN = 21.6 ~ 26.4V
—
—
75
mV
Load Regulation
Reg-L
IO = 0 ~ 100mA
—
—
750
mV
Ripple Voltage
VP-P
IO = 100mA
—
—
120
mV
h
IO = 100mA
—
75
—
%
Efficiency
EFFICIENCY VS. OUTPUT CURRENT
CHARACTERISTICS
EFFICIENCY VS. INPUT VOLTAGE
CHARACTERISTICS
VIN = 24V
Ta = 25°C
16
40
60
40
20
20
0
20
40
60
80
0
100 120 140
12
10
8
6
4
2
Io = 100mA
Ta = 25°C
18
14
20
22
24
26
0
28
0 20 40 60 80 100 120 140 160 180
OUTPUT CURRENT, IO, (mA)
INPUT VOLTAGE, VIN, (VOLTS)
OUTPUT CURRENT, IO, (mA)
OUTPUT VOLTAGE VS. INPUT VOLTAGE
CHARACTERISTICS
INPUT CURRENT VS. INPUT VOLTAGE
CHARACTERISTICS
DERATING
CHARACTERISTICS
20
140
300
Io = 100mA
Ta = 25°C
Io = 100mA
Ta = 25°C
240
12
8
4
120
OUTPUT CURRENT, IO, (mA)
16
INPUT CURRENT, IIN, (mA)
OUTPUT VOLTAGE, VO, (VOLTS)
OUTPUT VOLTAGE, VO, (VOLTS)
60
0
18
80
EFFICIENCY, h, (%)
EFFICIENCY, h, (%)
80
0
OUTPUT VOLTAGE VS. OUTPUT CURRENT
CHARACTERISTICS
100
100
180
120
60
0
5
10
15
20
INPUT VOLTAGE, VIN, (VOLTS)
2
Min.
25
30
0
100
80
60
40
20
0
5
10
15
20
INPUT VOLTAGE, VIN, (VOLTS)
25
30
0
-10
10
30
50
70
90
110
AMBIENT TEMPERATURE, (°C)
Rev. 01/10