RBU1001M THRU RBU1007M SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 10.0 Amperes FEATURES * * * * Low leakage Low forward voltage Surge overload rating: 200 amperes peak Mounting position: Any RBU MECHANICAL DATA .880 (22.3) .860 (21.8) * UL listed the recognizde component directory file # E252754 .140 (3.56) .130 (3.30) .740 (18.8) .720 (18.3) .512 (13.0) .080 (2.03) .060 (1.52) .160 (4.1) .140 (3.5) * Epoxy: Device has UL flammability classification 94V-O .710 (18.0) .690 (17.5) .085 (2.16) .075 (1.90) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. resistive or inductive load. .210 (5.33) .190 (4.83) .080 (2.03) .065 (1.65) .050 (1.27) .040 (1.02) .100 (2.54) .085 (2.16) .022 (0.56) .018 (0.46) Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) RATINGS SYMBOL RBU1001M RBU1002M RBU1003M RBU1004M RBU1005M RBU1006M RBU1007M UNITS Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Volts VDC 50 100 200 400 600 800 1000 Volts Maximum DC Blocking Voltage Maximum Average Forward Rectified Current o at T C = *100 C (Note 4) Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Current Squared Time Isolation Voltage of case Typical Thermal Resistance (Note 1) Operating and Storage Temperature Range IO 10.0 Amps I FSM 200 Amps I 2t 165.9 2 A /S VISO 1600 V AC R θ JC 2.3 R θ JA 26 T J, T STG -55 to + 150 0 C/ W 0 C ELECTRICAL CHARACTERISTICS (@TA=25 C unless otherwise noted) O CHARACTERISTICS Maximum Instantaneous Forward Voltage at 5.0A DC Maximum DC Reverse Current at Rated DC Blocking Voltage @T A = 25o C @T A = 100o C SYMBOL RBU1001M RBU1002M RBU1003M RBU1004M RBU1005M RBU1006M RBU1007M VF IR NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted. 2. "Fully ROHS compliant", "100% Sn plating (Pb-free)". 3. Equivalent to Vishay's GBU10 Series. 4. "*" Heat Sink Temperature. 5. Available in Halogen-free epoxy by adding suffix -HF after the part nbr. 1.1 UNITS Volts 5.0 100 uAmps 2013-04 REV: C 30 20 34 TC= 150 OC (TYP) 5 TC= 25 OC (TYP) 2 1 0.5 0.2 0 sine wave TJ = 150 OC 30 10 POWER DISSIPATION, (W) INSTANTANEOUS FORWARD CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( RBU1001M THRU RBU1007M ) Pulse test per one diode 0.2 0.4 0.6 0.8 1 1.2 1.4 20 10 0 1.6 0 INSTANTANEOUS FORWARD VOLTAGE, (V) 0 8.3ms 8.3ms 200 1 cycle non-repetitive Tj=25 100 0 0 1 2 5 10 20 50 4 10 12 14 3 P.C.B soldering land 5mmf sine wave R-load free in air 2 1 0 100 on glass-epoxi substrate 0 40 80 120 160 AMBIENT TEMPERATURE, (OC) FIG.4 TYPICAL FORWARD CURRENT DERATING CURVE FIG.3 SURGE FORWARD CURRENT CAPABILITY 10 2.4 THERMAL RESISTANCE (OC/W) AVERAGE FORWARD CURRENT, (A) 8 4 NUMBER OF CYCLE 8 6 heatsink Tc Tc 4 2 0 10 6 FIG.2 POWER DISSIPATION AVERAGE FORWARD CURRENT, (A) sine wave IFSM PEAK FORWARD SURGE CURRENT, (A) FIG.1 TYPICAL INSTANTANEOUS FORWARD CHARACTERITICS 300 2 AVERAGE RECTIFIED FORWARD CURRENT, (A) sine wave R-load on heatsink 30 50 70 90 110 130 HEAT SINK TEMPERATURE, (OC) 150 FIG.5 TYPICAL FORWARD CURRENT DERATING CURVE 170 with thermal compound 2.0 1.6 1.2 0.8 0.4 0 2 3 4 5 6 7 MOUNTING TORQUE (kg.cm) FIG.6 CONTACT THERMAL RESISTANCE fcf 8 Marking Description Rectron Logo UL Logo RBU100XM VYWW Year – code (Y:Last digit of year& A:2010, B:2011……) Week – code (WW:01~52) Part No. Voltage-code 1-------50V 2-------100V 3-------200V 4-------400V 5-------600V 6-------800V 7-------1000V PACKAGING OF DIODE AND BRIDGE RECTIFIERS TUBE PACK PACKAGE PACKING CODE EA PER BOX INNER BOX SIZE CARTON SIZE (mm) (mm) RBU -C 1,000 490*135*110 510*293*131 EA PER CARTON WEIGHT(Kg) 2,000 13.62 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.